Pentair 345303 Скачать руководство пользователя страница 6

2

 

CHALLENGER

®

 Centrifugal Pump Installation and User’s Guide

 

INSTALLATION

Location

Be sure the Challenger

®

 Centrifugal Pump location meets the following requirements:

Note: 

Do not install this pump within an outer enclosure or beneath the skirt of a hot tub or spa unless marked 

accordingly.
1.  Install the pump as close to the pool or spa as 

possible.  To reduce friction loss and improve 
efficiency use short, direct suction piping returns.

2.  Install a minimum of 5 feet (1.5 meters) from the 

inside wall of the pool or spa.  Canadian installations 
require a minimum of 9.8 feet (3 meters) from pool 
water.

3.  Install the pump a minimum of 3 feet (0.9 meters) 

from the heater outlet.

4.  Do not install the pump more than 10 feet (3 m) above 

the water level.

5.  Install the pump in a well ventilated location protected from excessive moisture (i.e., rain gutter downspouts, 

sprinklers, etc.).

6.  Install the pump with a rear clearance of at least 3 inches (7.6 cm) so that the motor can be removed easily for 

maintenance and repair. A vertical clearance of 12 inches (30.5 cm) is required for strainer basket removal.  See 

Figure 1

.

Piping, Fittings and Valves

1.  Use thread seal tape or pipe sealants on all male connections of pipes and fittings.  Use only pipe sealant 

compounds suited for plastic pipe. 

DO NOT USE PETROLEUM BASED PRODUCTS

.

2.  Support pipe to prevent strains on the systems filter, pump and valves.
3.  When connecting fitting to the pump, apply a pipe sealant to the threads and then hand tighten plus 1½ turns.  

DO 

NOT OVERTIGHTEN

.

4.  Long piping runs and elbows restrict flow.  For best efficiency, use the fewest possible fittings, large diameter pipe 

(at least 1.5 inches) and locate equipment as close to the pool as possible.  The pump suctions line should not be 
smaller than the pipe size on the inlet of the pump.

5.  Suction fittings must conform to ASME/ANSI A 112.19.8 M Standards.  Use double suction fittings.
6.  For most installations Pentair recommends installing a valve on both the pump suction and return lines so that 

the pump can be isolated during routine maintenance. We also recommend a valve, elbow or tee installed in the 
suction line should be no closer to the front of he pump than five (5) times the suction line pipe diameter. See 

Figure 1

Example: 

A 1.5 inch pipe requires a 7.5 inch (19 cm) straight run in front of the suction inlet of the pump. This will 

help the pump prime faster and last longer.

Note: 

DO NOT install 90° elbows directly into the pump inlet and outlet. 

Wiring Installation

RISK OF ELECTRICAL SHOCK OR ELECTROCUTION.

This pool pump must be installed by a licensed or certified electrician or a qualified pool serviceman in 
accordance with the all National Electrical Code and all applicable local codes and ordinances. Improper 
installation will create an electrical hazard which could result in death or serious injury to pool users, installers, 
or others due to electrical shock, and may also cause damage to property.
Always disconnect power to the pool pump at the circuit breaker before servicing the pump. Failure to do so 
could result in death or serious injury to serviceman, pool users or others due to electric shock.

1.  Make sure all electrical breakers and switches are turned off before wiring motor.
2.  Make sure that the wiring voltage matches the motor voltage. If they do not match permanent damage to the 

motor will occur.

3 IN.

(7.6 CM)

MINIMUM

REAR CLEARANCE

5x SUCTION PIPE 

DIAMETER

ELBOW

12 IN. (30.5 CM) 

MIN. VERTICAL 

CLEARANCE

Figure 1

Содержание 345303

Страница 1: ...IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS CHALLENGER INSTALLATION AND USER S GUIDE CENTRIFUGAL PUMP ...

Страница 2: ...PPORT Customer Service and Technical Support USA 8 A M to 7 30 P M Eastern Time Phone 800 831 7133 Fax 800 284 4151 Web site Visit www pentairpool com or www staritepool com Servicing Pump Disassembly The Shaft Seal Pump Reassembly Restart Instructions Priming the Pump Troubleshooting Replacement Parts Illustrated Parts View High Pressure Pump Parts List High Flow Pump Parts List Technical Data Di...

Страница 3: ...ND ALL INSTRUCTIONS IN THE OWNER S MANUAL BEFORE USING THIS PUMP THESE WARNINGSAND THE OWNER S MANUAL MUST BE LEFT WITH THE POOL OWNER SUCTION ENTRAPMENT HAZARD STAY OFF THE MAIN DRAINANDAWAYFROMALLSUCTION OUTLETS THE USE OF UNAPPROVED COVERS OR ALLOWING USE OF THE POOL OR SPA WHEN COVERS ARE MISSING CRACKED OR BROKEN CAN RESULT IN BODY OR LIMB ENTRAPMENT HAIR ENTANGLEMENT BODY ENTRAPMENT EVISCERA...

Страница 4: ...evels of suction can pose a risk if a person comes within the close proximity of the suction openings A person can be seriously injured by this high level of vacuum or may become trapped and drown It is absolutely critical that the suction plumbing be installed in accordance with the latest national and local codes for swimming pools The Virginia Graeme Baker VGB Pool and Spa SafetyAct creates new...

Страница 5: ...l produce one half the flow and 1 4 the pressure of high speed However the pressure required by the filter and pool plumbing at half flow will also be greatly reduced due to much lower system friction These lower friction losses result in great energy savings At one half flow low speed the electrical energy savings are 60 for equal amounts of circulated water Turn motor to low speed for quiet oper...

Страница 6: ...e at least 1 5 inches and locate equipment as close to the pool as possible The pump suctions line should not be smaller than the pipe size on the inlet of the pump 5 Suction fittings must conform to ASME ANSI A 112 19 8 M Standards Use double suction fittings 6 For most installations Pentair recommends installing a valve on both the pump suction and return lines so that the pump can be isolated d...

Страница 7: ...trical service ground On cord connected circuits check for proper grounding Bonding The National Electrical Code Article 680 22 requires that the motor be electrically bonded to appropriate permanently installed pool or spa hot tub structure by a solid copper conductor no smaller than No 8 AWG no smaller than No 6 AWG for Canadian installations Bonding wire should be connected from the accessible ...

Страница 8: ...ice to lubricate the lid o ring with silicone lubricant each time the lid is removed The o ring should be cleaned and inspected every time the strainer pot is opened 7 The lid should be replaced by pressing the lid down and twisting the lid clockwise 8 The pump is now ready to prime Energize the motor and the pump will prime The time to prime will depend on the suction lift and the distance and si...

Страница 9: ...rainer lid in a counter clockwise direction to remove the lid and remove the basket from the pump 5 Remove the debris from the strainer basket and rinse out the basket Replace the basket if it is cracked 6 Replace the basket 7 Fill the pump strainer pot and volute up to the suction inlet port with water 8 Clean the lid O ring and sealing surface of the strainer pot Note ItisimportantthattheO Ringb...

Страница 10: ... Electric Motor Care Protect from heat 1 Shade the motor from the sun 2 Any enclosure must be well ventilated to prevent overheating 3 Provide ample cross ventilation Protect against dirt 1 Protect from any foreign matter 2 Do not store or spill chemicals on or near the motor 3 Avoid sweeping or stirring up dust near the motor while it is operating 4 If a motor has been damaged by dirt it may void...

Страница 11: ...ion Be sure not to scratch or mar the polished shaft seal faces seal will leak if faces are damaged Pump Disassembly All moving parts are located in the rear sub assembly of this pump Refer to Figure 4 on page 9 for an illustrated parts view Tools required Adjustable wrench 1 4 inch flat blade screwdriver 9 16 inch open end wrench Rubber Mallet To remove and repair the motor sub assembly perform t...

Страница 12: ...piping by removing the band clamp and pulling the motor with pump bracket diffuser and impeller assembly away from front pump housing body The Shaft Seal consists primarily of two parts a rotating spring seal and a ceramic seal See Figure 3 The Challenger Centrifugal Pump requires little or no service other than reasonable care however a Shaft Seal may occasionally become damaged and must be repla...

Страница 13: ...crew Note The impeller screw is a left handed thread and tightens in a counter clockwise direction 5 Remount the diffuser spacer and diffuser using a 1 4 inch flat blade screwdriver and the three 3 diffuser screws 6 Reseat the pump housing strainer pot volute onto the rear sub assembly 7 Place the band clamp around the pump housing an rear sub assembly Tighten with the band clamp knob Note The ban...

Страница 14: ...is matter could cause a loss of pressure resulting in damage to the pump case impeller and seal and may cause property damage and personal injury Priming the Pump The pump strainer pot must be filled with water before the pump is initially started Follow these steps to prime the pump 1 Remove the pump lid 2 Fill the pump strainer pot with water 3 Reassemble the pump lid onto the strainer pot The p...

Страница 15: ...Clear basket 6 Closed valve in piping system Check all valves and open all necessary valves 7 Pump is on low speed two speed units only Adjust to high speed 8 Air leak in suction line Find fix leak Low Flow High Filter Pressure 1 Filter is dirty Clean filter 2 Restriction in return line Open return line restriction Low Flow Low Filter Pressure 1 Strainer basket or skimmer basket is clogged Clean b...

Страница 16: ...65 Strainer Pot Bolt 4x 17 355468 Housing 18 359507 357391 3HP Pot Assembly 19 357161 Drain Plug 2x 20 192115 Drain Plug O Ring 2x 21 355301 Lid 22 350013 Lid O Ring 23 355318 355441 3HP Strainer Basket 24 355300 Strainer Pot Motor Table Motor Model Single Speed Two Speed 3 Phase TEFC 1 2F 3 4A 355019S 3 4F 1A 355021S 355375S 1F 1 1 2A 355023S 355376S 1 1 2F 2A 355025S 355377S 2F 2 1 2A 355027S 35...

Страница 17: ... Housing O Ring 15 U30 74SS Motor Bolt 4x 16 354265 Strainer Pot Bolt 4x 17 355468 Housing 18 359507 Pot Assembly 19 357161 Drain Plug 2x 20 192115 Drain Plug O Ring 2x 21 355301 Lid 22 350013 Lid O Ring 23 355318 Strainer Basket 24 355300 Strainer Pot Motor Table Motor Motor P N 1 2F 3 4A 355019S 3 4F 1A 355021S 1F 1 1 2A 355023S 1 1 2F 2A 355025S 2F 2 1 2A 355027S 1FE 355011S 1 1 2FE 355013S 2FE...

Страница 18: ... 8 10 1 12 0 7 2 14 2 6 0 5 4 1 5 2 0 1 5 4 12 0 TECHNICAL DATA Motor P N Dimension A 354806S 354808S 22 3 354810S 22 7 354812S 23 4 355019S 355021S 24 4 355375S 24 6 355023S 24 8 355009S 25 2 355376S 25 3 355011S 355027S 25 4 355377S 25 8 355013S 25 9 355378S 26 3 355025S 355034S 355015S 355017S 26 4 ...

Страница 19: ...F and 3 4A B 3 4F and 1A C 1FE 1F and 1 1 2A D 1 1 2FE 1 1 2F and 2A E 2FE 2F and 2 1 2A Total Dynamic Head in Feet of Water Flow Rate in U S Gallons per Minute 0 100 110 100 110 120 130 140 150 160 80 90 80 90 60 70 60 70 40 50 30 40 50 20 10 20 30 10 0 High Pressure Pump Performance Curves G H I J K L BEST EFFICIENCY SIZING High Pressure Curve Key MOTOR G 1 2FE 1 2F and 3 4A H 3 4FE 3 4F and 1A ...

Страница 20: ...names and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentair Water Pool and Spa Inc Those names and brands may be the trademarks or registered trademarks of those third parties Because we are continuously improving our products and services Pentair reserves the right to change spe...