Pentair Pool Products Meteor Series Скачать руководство пользователя страница 7

Rev. E  2-22-02

7

P/N  99223000

Section X.

Technical Data

Replacement Parts

Item

Part

Description

No.

No.

1

50115100

MPV, 5 pos., 18" and 20" filter

1

50118100

MPV, 8 pos., 18" and 20" filter

1

50118200

MPV, 8 pos., 22" filter

2

155050

Gauge, Pressure

3

51020900

Clamp, multiport valve

4

98209000

Screw, clamp

5

98211400

Nut, clamp

6

51021700

MPV gasket, 18", 20", 22"

7

58812120

Tank assy., 18" filter

7

58812130

Tank assy., 20" filter

7

58812140

Tank assy., 22" filter

8

51005000

O-ring, drain/insp. fittings

9

86300300

Fitting, drain sand/water

10

86300500

Gasket, drain cap

11

86300400

Cap, drain

12

55007800

Drain assy., complete

13

55216000

Skid base, 18" filter

13

55215000

Skid base, 20, & 22" filter

14

711004

Clamp, hose

15

86201900

Adapter, hose, elbow

16

352256

Nut, quick connect

17

86013000

Hose, assy. for 18" filter

17

86013090

Hose, assy. for 20" filter

17

86013100

Hose, assy. for 22" filter

17

79302100

Hose, assy. braided for 18" filter 

Š

17

79302200

Hose, assy. braided for 20" filter 

Š

17

79302300

Hose, assy. braided for 22" filter 

Š

18

354571

O-ring

19

711006

Adapter, hose 1½"

20

Dynamo Pump, see note

           ITEMS NOT SHOWN

55025700

Lateral, 18", 20", 22"

55027500

Standpipe assy, 18" filter

55027600

Standpipe assy, 20" filter

55027700

Standpipe assy, 22" filter

85019300

Adapter, backwash

354265

Bolt, 5/16-18 x 3/4"

155005

Kit, 12 ft. hose, 2 per kit

155153

Kit, 6 ft. hose, 2 per kit

543110

Light ready fitting

NOTE: 

 See your dealer for correct motor and

                      cord replacement.

Š

  Used with Maxim pumps.

Содержание Meteor Series

Страница 1: ...951 West Los Angeles Ave Moorpark CA 93021 805 523 2400 Important Notice Attention Installer This manual contains important information about the installation operation and safe use of this product This information should be given to the owner operator of this equipment WARNING Before installing this product read and follow all warning notices and instructions accompanying this system Failure to f...

Страница 2: ...r death Section II How Your Filter Works Your high rate sand filter is designed to produce clear sparkling water and operate for years with a minimum of maintenance when installed operated and maintained in accordance with these instructions Your filter uses special filter sand to remove dirt particles from the water Dirt is collected in the filter by the sand bed as water flows through the filter...

Страница 3: ...labeled to insure proper connections 11 Install the valve clamp halves item 3 on page 7 over the flanges of the filter tank and the valve Ensure that the valve clamp halves are securely installed over BOTH flanges before attaching and tightening the bolts Tighten both bolts until both clamp halves touch 12 Attach hose assembly item 17 on page 7 to pump using the quick connect nut item 16 on page 7...

Страница 4: ...aste Stand clear of filter and start the pump 5 Run the pump for at least two minutes 6 Turn the pump off and set valve to filter position Ensure that all pool suction and return lines are open so that water is free to flow from and to the pool Stand clear of filter and start the pump 7 Your filter has now started its filtering cycle You should check that water is returning to the pool and take no...

Страница 5: ...of the filter and start pump 4 Backwash filter for approximately 3 5 minutes or until backwash water is clean 5 Turn off pump Set control valve back to rinse position 6 Stand clear of the filter and start pump 7 Rinsefilterforapproximately3 5minutes 8 Turn off pump Set control valve back to filter position 9 Stand clear of the filter and start pump 10 The filter has now started its filtering cycle...

Страница 6: ...lter 3 Partially closed valve or restriction Openvalveorremoveobstructioninreturnline Short filter cycles 1 Improperbackwash Backwashuntileffluentrunsclear 2 Poolchemistrynotadequatetoinhibitalgaegrowth Maintainpoolchemistryorconsultpoolservicetechnician 3 Pluggedsandbed Manuallyremovetop1 surfaceofsandbedandchemicallycleanasrequired 4 Flow rate too high Restrict flow to capacity of filter Returnf...

Страница 7: ...d base 18 filter 13 55215000 Skid base 20 22 filter 14 711004 Clamp hose 15 86201900 Adapter hose elbow 16 352256 Nut quick connect 17 86013000 Hose assy for 18 filter 17 86013090 Hose assy for 20 filter 17 86013100 Hose assy for 22 filter 17 79302100 Hose assy braided for 18 filter 17 79302200 Hose assy braided for 20 filter 17 79302300 Hose assy braided for 22 filter 18 354571 O ring 19 711006 A...

Страница 8: ...e skimmer opening A low water level can cause the pump motor to run dry which will damage the mechanical seal and cause external leakage 3 Shaft Seal Rotary Seal The shaft seal consists of two parts a Stationary ceramic seal press fitted into seal plate b A rotating spring loaded seal press fitted onto impeller shaft CAUTION The highly polished and lapped faces of the seal are easily damaged Handl...

Страница 9: ...Rev E 2 22 02 9 P N 99223000 This page is blank ...

Страница 10: ...P N 99223000 10 Rev E 2 22 02 This page is blank ...

Страница 11: ...Rev E 2 22 02 11 P N 99223000 This page is blank ...

Страница 12: ...P N 99223000 12 Rev E 2 22 02 ...

Отзывы: