Thank you for purchasing your
Hydromatic
®
pump. To help
ensure years of trouble-free
operation, please read the
following manual carefully.
Before Operation:
Read the following instructions
carefully. Reasonable care and
safe methods should be practiced.
Check local codes and
requirements before installation.
Attention:
This manual contains important
information for the safe use of
this product. Read this manual
completely before using this
product and refer to it often for
continued safe product use.
DO NOT THROW AWAY OR
LOSE THIS MANUAL. Keep it
in a safe place so that you may
refer to it often.
WARNING: Before handling
these pumps and controls,
always disconnect the power
first. Do not smoke or use
sparkable electrical devices or
flames in a septic (gaseous) or
possible septic sump.
To reduce risk of electrical shock:
1.
Risk of Electrical Shock:
This pump has not been
investigated for use in
swimming pool areas.
2.
Risk of Electrical Shock:
Connect only to a properly
grounded receptacle.
Septic tank is to be vented
in accordance with local
plumbing codes.
Do not smoke or use sparkable
electrical devices or flame in a
septic (gaseous) or possible
septic sump.
If a septic sump condition
exists and if entry into sump is
necessary, then (1) provide
proper safety precautions per
OSHA requirements and (2)
do not enter sump until
these precautions are strictly
adhered to.
Do not install pump in location
classified as hazardous per
N.E.C., ANSI/NFPA 70 - 1999.
Failure to heed above cautions
could result in injury or death.
General
Information
Pump
Warning
Approx. Turn-On Level
SW33A
9
1
/
2
"
SD33A
7
3
/
8
"
VS33A
8
3
/
8
"
Approx. Turn-Off Level
SW33A
3
7
/
8
"
SD33A
3
7
/
8
"
VS33A
3
7
/
8
"
Approx. Turn-On Level
SW50A
9
1
/
2
"
SD50A
7
7
/
8
"
VS50A
7
1
/
2
"
Approx. Turn-Off Level
SW50A
3
1
/
2
"
SD50A
3
3
/
8
"
VS50A
4"
2. Make sure float (Models
SW33/50 and VS33/50) hangs
free. It should not come into
contact with side or bottom of
sump.
3. Make sure sump is free of
string, cloth, nails, gravel, etc.
before installing pump.
4. Do not set pump directly on
the bottom of sump if it is not
solid. Raise the pump by
using bricks or concrete blocks
underneath it.
5. Use steel or plastic pipe for all
connecting lines between
pump and sewer outlet.
NOTE: Some city regulations
do not allow installing a
pump with plastic pipe.
Check local regulations.
6. Hydromatic check valve
should be installed in
discharge pipe, at least twelve
inches above the discharge
outlet of the pump.
These important instructions
must be followed for satisfactory
performance of your pump.
Before installation, check
your local electrical and
plumbing codes.
1. Provide proper sump.
Minimum Sump Diameter
SW/SD/VS50 18"
SW33
18"
SD/VS33
12"
2
Pump
Installation