ENERGY SAVING TIPS

1. If possible, keep pool or spa covered when not in

use. This will not only cut heating costs, but also
keep dirt and debris from settling in the pool and
conserve chemicals.

2. Reduce the pool thermostat setting to 78° F. or

lower. This is accepted as being the most healthy
temperature for swimming by the American Red
Cross.

3. Use an accurate thermometer.
4. When the proper maximum thermostat settings

have been determined, tighten the thermostat knob
stopper.

5. Set time clock to start circulation system no earlier

than daybreak. The swimming pool loses less heat
at this time.

6. For pools that are only used on the weekends, it is

not necessary to leave the thermostat set at 78° F.
Lower the temperature to a range that can be
achieved easily in one day. Generally, this would
be 10° F. to 15° F., if pool heater is sized properly.

7. During the winter or while on vacation, turn the

heater off.

8. Set up a regular program of preventative

maintenance for the heater each new swimming
season. Check heat exchanger, controls, burners,
operation, etc.

PRESSURE RELIEF VALVE

In some installations, a pressure relief valve (PRV)

is required on the MiniMax NT Series. To install a PRV,
remove the access
doors, remove
Flow Valve
assembly, then
carefully drill a
3/8 in. hole in
center of 3/4 in.
NPT port (on main
header) being
careful to drill 

only

through wall at
bottom of 3/4 in.
NPT port and no
deeper—now thread in
the 3/4 in. NPT PRV.

NOTE: 

 (A.S.M.E.

version varies slightly.
It is of bronze
construction, and is
supplied with the
A.S.M.E.  Section IV,
pressure relief valve
pre-installed at
factory.)

Test the relief valve
at least once a year
by lifting up lever.

FOR PRV
INSTALLATION
DRILL THRU
THE NPT PORT

RELIEF
VALVE

REMOVE FLOW VALVE 
BEFORE DRILLING
THE NPT PORT

STANDARD

TSI

RELIEF VALVE

TO WINTERIZE,
OPEN DRAIN VALVE

A.S.M.E. VERSION

CAUTION

REMOVE THE FLOW VALVE ASSEMBLY WHEN DRILLING
THE HOLE TO INSTALL A PRV, OTHERWISE, YOU WILL
DRILL INTO THE VALVE ASSEMBLY.

Figure 28.

Section VI. Maintenance

Maintenance Instruction

Figure 29.

It is recommended that you check the following items at
least every six months and at the beginning of every
swimming season.
1. Examine the venting system. Make sure there are no

obstructions in the flow of combustion and
ventilation air.

2. Visually inspect the main burner and the hot surface

ignitor. The normal color of the flame is blue. When
flame appears yellow, burners should be inspected
and cleaned. Check ignitor for damage.

3. Inspect the heat exchanger for soot.  Clean as

necessary.

4. Remove burner tray and clean burners and main

burner orifices.

5. Keep the heater area clean and free from

combustibles and flammable liquids.

6. Check wire ends and wire connections.  They should

be clean and tight.

7. Check the gas pressure (supply and manifold) as

described in this manual.

A.S.M.E. VERSION

STD

TSI

Содержание HTR-200-NT Series

Страница 1: ...loss of life Improper installation adjustment alteration service or maintenance can cause property damage personal injury or death Installation and service must be performed by a qualified installer s...

Страница 2: ...194 Web site visit www pentairpool com to find information about Pentair Water Pool and Spa Inc 2004 Pentair Water Pool and Spa Inc 1620 Hawkins Ave Sanford NC 27330 919 556 8000 10951 West Los Angele...

Страница 3: ...16 Vent Adaptors 16 Indoor Installations Venting Guidelines 17 Outdoor Installations Venting Guidelines 18 Outdoor Vent Kit 18 Electrical Connections 19 Wiring Diagram NT STD TSI with DDTC 20 Section...

Страница 4: ...the identification system 1 HTR Heater 2 200 250 300 or 400 Input rating Btu hr X 1000 3 NT MiniMax NT Series 4 STD or TSI Series Character 5 NH or PH Gas type Natural gas or Propane gas and ignition...

Страница 5: ...f for any reason the heater is improperly installed and or operated Be sure to follow the instructions set forth in this manual If you need any more information or if you have any questions regarding...

Страница 6: ...hermostats may err in regulating water temperatures by as much as 4 F 5 Persons with a medical history of heart disease circulatory problems diabetes or blood pressure problems should obtain their phy...

Страница 7: ...ctor bears the appropriate license See Figure 1 for Outdoor and Indoor Installations SPECIFICATIONS Section III Installation Installation Instructions MODEL 200 250 24 63 21 63 A DIM 300 400 34 13 27...

Страница 8: ...eater and is equipped with a positive seal noncorrosive Check Valve P N R172288 between the feeder and heater l e d o M M P G n i M M P G x a M 0 0 2 0 2 0 2 1 0 5 2 0 3 0 2 1 0 0 3 0 3 0 2 1 0 0 4 0...

Страница 9: ...left large access doors It is not necessary to remove the top of the heater to gain access to the headers 2 Disconnect all wires from the high limit switches except the short jumper wire NOTE Do NOT r...

Страница 10: ...he support bracket 10 Reconnect all the high limit wires and the pressure switch wiring routing the wires through the same hole as the thermostat sensor wires 11 Pump and bleed system to check the hea...

Страница 11: ...ally be of a larger size than the gas valve supplied with the heater Therefore a reduction of the connecting gas pipe will be necessary Make this reduction as close to the heater as possible The heate...

Страница 12: ...T N E L A V I U Q E M U M I X A M t F t o o F c i b u C r e p U T B 0 0 0 1 t a s a G l a r u t a N t o o F c i b u C r e p U T B 0 0 5 2 t a s a G e n a p o r P L E D O M 2 1 4 3 1 4 1 1 2 1 1 2 2 1...

Страница 13: ...TSI MiniMax NT STD Inlet Manifold Illustrations above are for Natural Gas for Propane requirements see Table 7 1 Push the power switch to OFF 2 Turn the gas valve knob to OFF 3 Remove 1 8 in NPT plug...

Страница 14: ...earance recommendation by the vent pipe manufacturer the requirements of the Uniform Mechanical Code should be met The ventilation air requirements for the MiniMax NT heater can be found on page 16 It...

Страница 15: ...ate drainage be installed under the heater The pan must not restrict air flow It is recommended to install the heater on fire resistance slabs Do not install the heater directly on a combustible wood...

Страница 16: ...ding r o f a e r A n e p o e e r F t e N s e h c n I e r a u q S g n i n e p O h c a E r e t a e H e z i S m o r f d e t c u D e d i s t u O m o r f t c e r i D e d i s t u O 0 0 2 0 0 1 0 5 0 5 2 5 2...

Страница 17: ...m any door window or gravity air inlet 4 ft below 4 ft horizontally 1 ft above Air Supply Clearances indicated are for non mechanical air supply inlet to the building For mechanical air supply inlet a...

Страница 18: ...36 in between the air conditioning unit and the heater Outdoor Shelter Installation in Canada see page 15 Section III Installation VENTING GUIDELINES OUTDOOR INSTALLATION Must be at least 3 ft above...

Страница 19: ...e 17 If any of the original wiring supplied with this heater must be replaced installer must supply No 18 AWG 600V 105 C U L approved AWM low energy stranded copper wire or it s equivalent Thermal fus...

Страница 20: ...ERMIQUE DOIT ETRE REMPLACEE JI0 VLV HLMT 24V J4 J7 J9 P9 IGN J11 IGN 120 GND 24VAC IGN FS IGN 240 VLV W O R PR GY TH PS BK BR Y L2 L1 J17 BL FC F1 F2 W W J16 BK BLACK NOIR BL BLUE BLEU BR BROWN MARRON...

Страница 21: ...ower switch to OFF see Figure 25 3 Set the thermostat to OFF see page 27 4 This appliance is equipped with an ignition device which automatically lights the burners Do not try to light the burn ers by...

Страница 22: ...Pool Level Installation instructions on page 8 The switch may remain closed with no water flow if there is more than a 3 ft elevation difference between the heater heat exchanger and the pool water li...

Страница 23: ...he heat up and TFI periods and continues thereafter for another 30 seconds at low speed then return to full speed for the remainder of the heating cycle The thermostat air pressure switch and burner f...

Страница 24: ...re of the water returning to the heater depending on which mode has been selected Pool or Spa This is accomplished by a thermister sensor on the inlet port of the water header of the heater and workin...

Страница 25: ...Rev D 12 22 04 P N 472235 25 Section IV Operation Figure 27...

Страница 26: ...be seen from the front of the control panel five are system indicators and four are mode indicators which helps you understand the operation of the heater see Figure 26 If something should go wrong t...

Страница 27: ...remote control systems In order to operate by a remote control system the REMOTE mode must be selected on the front panel When the REMOTE mode is selected the REMOTE LED will light up REMOTE CONTROL T...

Страница 28: ...on there is a failure within the heater control system or a DDTC internal fault The DDTC will display the actual temperature or set point temperature or OFF as selected by the user When DDTC detects a...

Страница 29: ...operating after pump has shut off Shut off gas supply and call serviceperson Heater exchanger scaled Shut off gas supply and call serviceperson SERVICE CHECKS IGNITION MODULE m o t p m y S e r u C e...

Страница 30: ...main header being careful to drill only through wall at bottom of 3 4 in NPT port and no deeper now thread in the 3 4 in NPT PRV NOTE A S M E version varies slightly It is of bronze construction and i...

Страница 31: ...ze damage to the exchanger or headers Freeze damage is specifically not covered by the warranty If the pool won t be used for a month or more turn the heater off at the main gas valve For areas where...

Страница 32: ...once every month or so to be sure it is being maintained See your local pool dealer for help in properly balancing the water chemistry 7 2 6 8 7 0 7 4 7 6 7 8 8 0 8 2 8 4 Add Soda Ash or Sodium Bicarb...

Страница 33: ...Rev D 12 22 04 P N 472235 33 REPLACEMENT PARTS NT STD w DDTC all Models NT TSI w DDTC 200 250 and 300 Models FOR TSI ONLY 29 30 31 33 34 35 36 FOR STD ONLY...

Страница 34: ...P N 472235 Rev D 12 22 04 34 B J K Q X Q J J Q J J Q J J J J YY Q Z J B B X J _ _ _ _ _ K Q K Q J J J J Q Y _ Y Y _ Y _ Y _ Y Z B Y K Q J Q K Q K Q B Y J J YY Z Y Z X Z Z Q J Z J J JJ JJ J J Z _ Z J...

Страница 35: ...J J Q J J J J YY Q Z J B B X J _ _ _ _ _ K Q K Q J J Q X Y _ Y Z B Y K Q J J Q K Q K Q B Y J J YY Z Y Z X Z Z Q J J J _ Y Z J Z _ Z JJ J JJ Replacement Parts for the 400 Model Series are for models m...

Страница 36: ...D 12 22 04 36 1 4 3 6 8 10 11 13 46 45 44 42 41 30 31 32 25 35 38 39 2 7 12 22 21 27 29 43 40 36 15 28 24 20 16 14 23 9 17 26 18 5 19 34 33 37 REPLACEMENT PARTS NT TSI w DDTC 400 Model Starting w Seri...

Страница 37: ...Rev D 12 22 04 P N 472235 37 J J B K JJ Q X Q Q Y _ Y _ Y J _ J _ _ K Q J K Q _ JJ J _ B X J X B X YY J YY Q Q Q J YY Q B Y J K Q Z Q Z K Q K Q B Y YY Z Y Z X Z Z Q J...

Страница 38: ...P N 472235 Rev D 12 22 04 38 NOTES...

Страница 39: ...Rev D 12 22 04 P N 472235 39 NOTES...

Страница 40: ...P N 472235 Rev D 12 22 04 40 40 Pentair Water Pool and Spa Inc 1620 Hawkins Ave Sanford NC 27330 919 566 8000 10951 W Los Angeles Ave Moorpark CA 93021 805 523 2400 SAVE THESE INSTRUCTIONS...

Отзывы: