background image

P/N 350039   Rev. C   8-24-06

2

OptiFlo

®

 Engineered Plastic Pump Installation, Operation & Service Manual

Table of Contents

SECTION I.

HOW YOUR PUMP WORKS ............................................................................................... 3

SECTION II.

INSTALLATION ................................................................................................................. 3-6

SECTION III. PUMP OPERATION AND MAINTENANCE ....................................................................... 6

SECTION IV.

SEAL REPLACEMENT PROCEDURE ............................................................................  6-7

SECTION V.

WINTERIZING PROCEDURE .............................................................................................. 7

SECTION VI. TROUBLESHOOTING GUIDE ............................................................................................. 8

SECTION VII. TECHNICAL DATA ........................................................................................................  9-12

WARNING

To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times.

WARNING

Before installing this product, read and follow all warning notices and instructions accompanying this pump. Failure to follow safety warnings and instructions
can result in severe injury, death, or property damage.  Call (800) 831-7133 for additional free copies of these instructions.

Important Notice

Attention Installer.

This manual contains important information about the installation, operation and safe use of this product. This information should be
given to the owner/operator of this equipment.

PUMP SAFETY INSTRUCTIONS

When installing and using this electrical equipment, basic safety precautions should always be followed, including the

following:

WARNING

RISK OF ELECTRICAL SHOCK OR ELECTROCUTION

This pool pump must be installed by a licensed or certified electrician or a qualified pool serviceman in accordance with the National Electrical
Code and all applicable local codes and ordinances. Improper installation will create an electrical hazard which could result in death or
serious injury to pool users, installers,   or others due to electrical shock, and may also cause damage to property.

Always disconnect power to the pool pump at the circuit breaker before servicing the pump. Failure to do so could result in death or serious
injury to serviceman, pool users or others due to electric shock.

WARNING

Risk of Electrical Shock. Connect only to a grounding type receptacle protected by a ground-fault circuit-interrupter (GFCI). Contact a qualified electrician
if you cannot verify that the receptacle is protected by a GFCI.

WARNING

Do not bury the electrical cord. Locate the cord to minimize the abuse from lawn mowers, hedge trimmers, and other equipment.

WARNING

To reduce the risk of electrical shock, replace damaged cord immediately.

Содержание 4HP-VD - 3' STD

Страница 1: ...3 or 805 553 5000 Visit us on the Internet at www pentairpool com or www staritepool com IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Thismanualcontainsimport...

Страница 2: ...TYINSTRUCTIONS When installing and using this electrical equipment basic safety precautions should always be followed including the following WARNING RISK OF ELECTRICAL SHOCK OR ELECTROCUTION Thispool...

Страница 3: ...eller to turn and this causes the water to flow The water flows into the hair and lint pot inlet and through the basket assembly to pre strain large particles The flow then enters the center of the pu...

Страница 4: ...PRODUCTS 11 Avoid over tightening the pipe threads when connecting fittings to the pump Proper procedure is to apply a pipe sealant to the thread and then install hand tight plus 1 1 2 turns DO NOT O...

Страница 5: ...d from the accessible wire connector on the motor shell to all metal parts of the swimming pool spaorhottubstructureandtoallelectricalequipment metalconduitandmetalpipingwithin5feetoftheinside walls o...

Страница 6: ...the pump will prime The time to prime will depend on the suctionliftandthedistanceandsizeofsuctionpiping Turnoffpowerifthepumpdoesnotprimewithinfive minutes and refer to the Troubleshooting Guide sect...

Страница 7: ...vertightenthebolts Graduallybringboltsuptofinaltightnessbymovingacrossinacriss cross pattern 11 Check the position of the mechanical seal set in the seal plate and ensure the motor shaft is in the cen...

Страница 8: ...n line Open return line restriction Low flow low filter pressure Strainer basket or skimmer basket Clean basket clogged Clogged impeller Clean obstruction Air leak in suction line Find and fix leak Re...

Страница 9: ...11 355667 Basket 12 357215 Seal Plate 13 350103 O ring 14 98209000 1 4 20 x 1 5 Machine Screw 4 req 15 Motor s 356597 Motor TB 3 4 hp 1ph 60hz 115V w switch 356595 Motor TB 1 hp 60hz 115V w switch 35...

Страница 10: ...No Description 1 354621 Enclosure Housing 2 356436 Motor 3 4 hp 48 Frame 2 356437 Motor 1 hp 48 Frame 2 356440 Motor 1 1 2 hp 48 Frame 3 354881 Cap CSA Mtr Enclsr w 3 Screws 4 154716 Screw Self Tappi...

Страница 11: ...METERS OF WATER CUBIC METERS PER HOUR 3 4 HP 3 4 HP 1 HP 1 HP 1 5 HP 1 5 HP 3 4 HP 1 HP 1 5 HP 0 2 4 6 8 10 0 5 10 15 Pentair Pool Products OptiFlo Series 60 Hz Pump Curves 0 10 20 30 40 50 60 0 10 2...

Страница 12: ...QXQ ZQ Q K QXQ ZQ Q QXQ ZQ Q K QXQ ZQ Q QXQ ZQ Q K QXQ ZQ Q QXQ ZQ Q K QXQ ZQ Q QXQ ZQ Q K ZQ Q ZQ Q K SAVE THESE INSTRUCTIONS 2006 Pentair Water Pool and Spa Inc All rights reserved This document is...

Отзывы: