51
3.
The display will alternate between “VAL 51” the current coin value. The
appropriate LED will also be lit. Key in the value of the coin if different, and press
the PRINT button to continue.
4.
The display will alternate between “SS 52” and the current sample size. Key in the
number of coins in the sample. (Max sample size is 250).
5.
The display will alternate between “nol 53” and “0.0”. Make sure that no weight
is on the platform and press the PRINT button to enter the “no load” condition.
6.
The display will alternate between “add” and the sample size entered in step 5
above. Place the indicated number of coins on the platform, and press the PRINT
button to enter the sample weight.
7.
The display will show calculated piece weight, in grams, for two seconds. The
scale will then be at Configuration Group 60. You may now key in “0” to exit
calibration, return to step 2 above and key in “50” to re-calibrate another coin
piece weight, or press PRINT to enter Configuration Group 60.
8.
When you exit calibration, the new piece weights will be stored in the scale
memory. The display will blank, and then the diagnostics countdown will begin.
9.
To restore the default coin piece weights and values (Quarter, Dime, Nickel,
Penny), Unplug the scale and press the internal calibration button while plugging
the scale back in. NOTE: This will also restore the default RS-232 setup (300
baud, 7 data bits, 1 stop bit, odd parity) and print formats.
The following RS-232 Interface Commands have been added or modified for this application:
SCM
– Select Coin Mode – Same as pressing the COIN button on the keypad.
SWM
– Select Weigh Mode – Same as pressing the UNITS button on the keypad.
IPW
[coin] [pc wt] – Input piece weight – Modified to require specifying the coin for which
the piece weight is being entered, using 0 for Coin A, 1 for Coin B, 2 for Coin C, and 3
for Coin D. For example, entering “IPW 2 5.00” enters a piece weight of 5.00 grams for
Coin C. (NOTE: the piece weight is always specified on grams.)
SGW
– Send Gross Weight _ Modified to send the Gross value of the coins on the platform,
if the scale is in the coin mode.
SNW
– Send Net Weight – Modified to send the Net value of the coins on the platform, if the
scale is in the Coin mode.
SCO
– Send Count – Modified to include a suffix indicating the current Coin selected.
SPW
– Send Piece Weight – Modified to include a suffix indicating the current Coin
selected.
The following Print Format Codes have been added or modified for this application: