17-00001-C
Page | 51
Step 3: Non-conductive mode test
There are three (3) Steps in this
testing procedure.
Do not skip or ignore any of them!
2.
If you have just completed Step 2:
a. The machine is
On
and the green light in the
On
Switch is still illuminated. If not, return to Step 1
Safety switch test procedure
and restart the machine by following
Instruction in
Steps 1 and 2
.
b. The Conductive/Non-Conductive mode is displayed in the
Conductive selection
. Select
Non-conductive
from the touch screen display.
c. Verify Auto
Run
is selected.
d. The machine
’
s Force has been set to deliver 3,000 lb/13 Kn. If this has been changed, repeat
the instructions in
Step 2, Instruction 4.
e. Verify the 1 in./25 mm Flat Anvils are installed in both the Upper and Lower Tool Holders
.
3.
Turn the Conductive/Non-Conductive
Switch to the Non-Conductive position.
4.
Keep your hands away from the tooling area.
Depress the Down Footswitch. The Upper Tool Holder
should move down, the flat Anvils will contact, and the Upper Tool Holder should
stop immediately
.
If this machine completes the above sequence correctly, go to
Instruction 4.
When operating this Hardware
Insertion Machine in the Non-
Conductive Mode, be very careful! Do not depress the Down
Footswitch a second time after the
Upper Tool Holder has
stopped on the down stroke with any part of
your body near
the tooling area.
a.
If the machine
does not
complete the above sequence correctly, check the touch screen
settings. If they are not correct, reset them and repeat the test. If the machine performs
correctly, go to
Instruction 3.
b.
If the machine
does not
complete the above sequence correctly, there is a
failure
in the
machine
’
s control circuit and it must be corrected by qualified personnel. Immediately
turning the machine
Off
by pressing the red
Off
Switch and turn the Main Disconnect
Switch to the Off position. The machine
’
s Main Disconnect Switch must be locked in the
Off
position until repairs are begun. Do not operate this machine until qualified personnel
have repaired the machine and the Non- Conductive Mode has been properly tested.
4. Remove your foot from the Foot pedal switch box.
Содержание Haeger 824 WindowTouch-4e
Страница 1: ...17 00001 C Page 1 824 WindowTouch4e Operation Manual ...
Страница 40: ...17 00001 C Page 40 Lockout Tagout continued 3 4 5 Touch on Exit Touch on Shut Down Turn OFF Computer ...
Страница 111: ...17 00001 C Page 111 155 Program Ends and returns to Main Screen ...
Страница 128: ...17 00001 C Page 128 Diagnostics From Main Screen 156 157 Select Administrator Then touch on OK Touch on ADMIN ...
Страница 136: ...17 00001 C Page 136 Parts List Main Assembly ...
Страница 138: ...17 00001 C Page 138 Parts List MAS 350 Bowl Assembly ...
Страница 141: ...17 00001 C Page 141 Parts List Quick Mount Assembly ...
Страница 143: ...17 00001 C Page 143 Parts List Muti Shuttle 2 Assembly ...
Страница 145: ...17 00001 C Page 145 Parts List HMI Arm Assembly ...
Страница 147: ...17 00001 C Page 147 Parts List TIS Assembly ...
Страница 153: ...17 00001 C Page 153 Parts List Hydraulic Cylinder Main Assembly ...
Страница 155: ...17 00001 C Page 155 Parts List Electrical Cabinet High Low Voltage Assembly ...
Страница 158: ...17 00001 C Page 158 Parts List Hydraulic Reservoir Assembly ...
Страница 161: ...17 00001 C Page 161 Parts List Hydraulic Manifold Assembly ...