System Components 

The Photoreactor m2 is comprised of the following components: 

 

Base Unit 

 

450nm LED Module* 

 

8ml Reflector 

 

40ml Reflector 

 

gc Vial Holder 

 

4ml Vial Holder 

 

8ml Vial Holder 

 

20ml/40ml Vial Holder 

 

Power Supply 

 

Power Cable 

 

*420nm and 365nm wavelength LED modules are separately available 

 

Choosing a Location 

Set the Photoreactor m2 horizontally

 

on its four neoprene feet

 

on a flat surface in a place that allows for 

adequate air ventilation on the back and bottom.  Do not place the Photoreactor m2 on top of paper or 
loose material that may be drawn into any ventilation port. Do not position the unit so that the back of 
the unit is obstructed. The Photoreactor m2 should only be transported in the horizontal position. 

 

NOTE: 

For adequate ventilation, maintain at least 4” of 

clearance around all sides of the unit in an unenclosed 
space.  

 

Connecting the Power Cord 

Insert the power supply receptacle-end into the receptacle on the side of the unit.  Insert the power cord 
plug into a standard AC outlet.  
 

 

Warning:  To  avoid  risk  of  electric  shock,  this 
equipment must only be connected to a supply mains 
with a protective earth. 

 

Содержание Photoreactor m2

Страница 1: ...User Manual Rev C Penn Photon Devices LLC 1055 Mensch Dam Road Pennsburg PA 18073 USA Tel 011 267 923 8798...

Страница 2: ...nents 6 4 2 Choosing a Location 6 4 3 Connecting the Power Cord 6 5 Operation 7 5 1 Setup 7 5 2 Performing a Photoredox Cycle 9 5 3 Termination Turning the Unit Off 11 6 System Information 12 7 Proper...

Страница 3: ...parameters Intertek ETL CE and CB approved User defined parameters including temperature light intensity fan speed and stirring Auto stop pause and reset options Supports vial sizes gc 4 8 20 40 ml T...

Страница 4: ...supply may cause damage to the device and or power supply and may result in injury It is the responsibility of the user to assess and mitigate any hazards that may result from a mixing interruption I...

Страница 5: ...5 3 System Overview Light Shield LED Module Touchscreen Base Unit Reflector Vial Holder...

Страница 6: ...ack and bottom Do not place the Photoreactor m2 on top of paper or loose material that may be drawn into any ventilation port Do not position the unit so that the back of the unit is obstructed The Ph...

Страница 7: ...onitoring or control is desired connect a K type thermocouple to the K type connector Pass the thermocouple through the opening at the rear of the light shield see below and place the distal end withi...

Страница 8: ...8 Warning To avoid damage to the device ensure the thermocouple does not come into contact with any moving parts i e stir magnet motor or fan Thermocouple path...

Страница 9: ...press Start To customize set points press Change Settings on the main display The user interface opens the settings screen shown left The following set points can be customized Duration HH MM SS up t...

Страница 10: ...all values can still be edited by changing the parameters as described above Changes in set points will take effect as soon as the DONE button is pressed on the dial or keypad screens with the excepti...

Страница 11: ...ton will reset the device to the parameters set for the last cycle Parameters may be changed as described previously and another reaction may be initiated During a cycle the Stop button will immediate...

Страница 12: ...bserve all labeling Immediately notify the manufacturer of any defects Cleaning Disinfection and Disposal Clean and disinfect the external housing of the Photoreactor m2 with a mild detergent Wipe wit...

Страница 13: ...2 cm 4 8 inches Height 33 8 cm 13 3 inches Depth 42 67 cm 16 8 inches Weight Approximately 2 kg 4 4 lbs Operating mode Continuous Main cable 10 A 250 V Power supply 85 264V 50 60 Hz 120VA Expected Se...

Страница 14: ...14 10 Product Ratings For all CE compliance questions EU customers may contact Necsel IP Inc an Ushio Group company 101 Panton Road Vergennes VT 05491 USA Tel 011 802 877 2182...

Отзывы: