Do Not Over-Fire
It is possible to fire the stove beyond its design capacity, this could damage the
stove, so watch for signs of over-firing – if any part of the stove starts to glow
red, the fire is in an over fire situation, and the controls should be adjusted
accordingly. Never leave the stove unattended for long periods without
adjusting the controls to a safe setting – careful air supply control should be
exercised at all times and only add the recommended quantity of fuels.
Smoke and Fumes Entering the Room
When properly installed and operated, this appliance will not emit fumes into
the room. Occasional fumes from de-ashing and refuelling may occur and is
normal. Persistent fume emission with closed doors must not be tolerated.
If fume emission does persist, then the following immediate action should be
taken:
1.
Evacuate the room, opening doors and windows on your exit to
ventilate the room.
2.
Let the fire go out, or eject and safely dispose of fuel from the appliance.
3.
Check for a flue blockage and clean if required.
Do not attempt to relight the fire until the cause has been identified and
corrected. If necessary, seek professional advice.
These situations are very dangerous and must NOT be tolerated. A list of
Qualified Engineers is available from
UK Solid Fuel Association
R. o. I.
7 Swanwick Court
Irish National Fireplace Organisation
Alfreton
162 Chapel Street
Derbyshire
Dublin
DE55 7AS
Ireland
Tel. 0845 601 4406
Tel. 01 801 5959
Chimney Fire
Identified by loud roaring sounds, dense smoke and sparks exiting chimney.
Shut down all air supply to stove by closing air vents, ensure the stove door fully