Penman Collection Helios 8 Скачать руководство пользователя страница 1


 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

HELIOS 8 

MULTI FUEL STOVE 

 

 

 

APPROVED - CONFORMING TO EN13240:2001 and 

EN13240 A2:2004 

 

 
 
 

 
 

 
 

 

INSTALLATION AND OPERATING INSTRUCTIONS 

STOVES MUST BE FITTED BY APPROVED, QUALIFIED AND  

COMPETENT INSTALLERS 

 

PLEASE LEAVE THIS BOOKLET WITH THE HOUSEHOLDER 

Penman Stoves operate at very high temperatures.  All persons  

including children and the infirm should be warned of this and not  

allowed to touch any surfaces whilst in use.  The operator must use  

the glove provided. 

 

www.penmancollection.com 

 

   HELIOS 8 INSTRUCTIONS – REV. 0 – JULY 2016 

Содержание Helios 8

Страница 1: ...QUALIFIED AND COMPETENT INSTALLERS PLEASE LEAVE THIS BOOKLET WITH THE HOUSEHOLDER Penman Stoves operate at very high temperatures All persons including children and the infirm should be warned of thi...

Страница 2: ...CONTENTS STOVE CONTROLS OUTPUT EFFICIENCY PAGE 03 COMPONENT PARTS PAGE 04 INSTALLATION PAGE 05 OPERATION PAGE 10 GENRAL MAINTENANCE PAGE 16 SAFETY NOTES TROUBLESHOOTING PAGE 18 STOVE ACCESSORIES PAGE...

Страница 3: ...ronmental Services in the Netherlands Variations may occur due to installation atmospheric conditions and fuel quality HELIOS 8 FUEL WOOD ANTHRACITE EFFICIENCY 80 81 2 FLUE GAS TEMPERATURE 309 C 287 C...

Страница 4: ...made specifically for your stove ITEM DESCRIPTION ITEM DESCRIPTION 1 Stove body 8 Flue blanking plate 2 Hinge set 9 Primary air slide assembly 3 Door casting 10 Fuel retaining bar 4 Side brick 11 Baff...

Страница 5: ...SUPPLIERS ACCEPT NO RESPONSIBILITY IF THIS ADVICE IS NOT FOLLOWED THIS APPLIANCE HAS BEEN EXTENSIVELY TESTED FOR SAFETY AND EFFICIENCY DO NOT ATTEMPT TO MODIFY IT ALWAYS USE GENUINE REPLACEMENT PARTS...

Страница 6: ...m If any of these requirements are not met the chimney should be lined by a suitable method When installing your Helios stove a 150mm flue liner may be used in accordance with the Building Regulations...

Страница 7: ...remove the baffle plates bricks and door Place in a secure place to avoid damage Refit after installation Upon completion of installation the appliance should be checked under fire for soundness of j...

Страница 8: ...ireplace built from non combustible materials but a permanent free air gap of at least 100mm should be left around the sides and top to obtain maximum heat output and for access to the rear of the sto...

Страница 9: ...talling without a flue draft stabiliser into houses built before 2008 at least 2200mm2 additional means of permanent ventilation direct to outside is required For houses built after 2008 at least 4950...

Страница 10: ...to the environment Slide to the right to open and to the left to close Use this to control wood fires It should be closed when burning solid fuels other than wood for the best efficiency after the fi...

Страница 11: ...fficiency when a bright fire is achieved using minimum air inlet and the Penman Stove Thermometer purchased separately registers within the Best Burn range Wood Burning Wood burns best on a bed of ash...

Страница 12: ...ar chamber brick are not covered by the fuel Of course best burning depends on the type of fuel being burnt draft and stove settings so please do experiment to find your own best settings De ashing Du...

Страница 13: ...pliance is designed to be operated with the door closed except for refuelling Not only is it unsafe to operate with the door open but the appliance efficiency will be significantly reduced and excess...

Страница 14: ...sh such that the new fuel ignites in a reasonable period If there are too few embers in the fire bed add kindling to prevent excessive smoke Fuel overloading The maximum amount of fuel specified in th...

Страница 15: ...nested in the chimney or the masonry may have cracked Both chimney and flue pipe must be swept at least once a year It is recommended that you have your chimney swept every six months It may be necess...

Страница 16: ...then your stove needs to be dried and the cause of the problem rectified After a shut down and before reuse the appliance should be cleaned again and the chimney swept it is essential to have the chi...

Страница 17: ...d doors must not be tolerated If fume emission does persist then the following immediate action should be taken 1 Evacuate the room opening doors and windows on your exit to ventilate the room 2 Let t...

Страница 18: ...up or furniture blocking vents Poor quality fuel Only burn dry seasoned timber soft woods have a lower heat output than hard woods Use the Penman Moisture Meter Solid fuels vary in heat value check w...

Страница 19: ...tailer will be able to supply Penman matching graphite high temperature paint Stove Glass Cleaner Spare Rope Rope Seal Adhesive CO Detector Penman Stove Fan Penman Stove Thermometer Wood Moisture Mete...

Страница 20: ...20 Brought to you by Percy Doughty Co Imperial Point Express Trading Estate Stone Hill Road Farnworth Bolton BL4 9TN 01204 868 550 www penmancollection co uk...