— Chapter 1. Overview
RF-7000E Operations Manual
16
Table 7 Coaxial Attenuator Pads
Part Number
Attenuation
Part Number
Attenuation
149-0128-01
1.0 dB
149-0128-11
11.0 dB
149-0128-02
2.0 dB
149-0128-12
12.0 dB
149-0128-03
3.0 dB
149-0128-13
13.0 dB
149-0128-04
4.0 dB
149-0128-14
14.0 dB
149-0128-05
5.0 dB
149-0128-15
15.0 dB
149-0128-06
6.0 dB
149-0128-16
16.0 dB
149-0128-07
7.0 dB
149-0128-17
17.0 dB
149-0128-08
8.0 dB
149-0128-18
18.0 dB
149-0128-09
9.0 dB
149-0128-19
19.0 dB
149-0128-10
10.0 dB
149-0128-20
20.0 dB
Coaxial Attenuator Pads: equipped with SMA male and female connectors and rated to 18 GHz.
May be inserted in receive or transmit lines for RF level coordination. Transmission engineering will determine
attenuator requirements.
Table 8 Spare and Accessory Equipment
Part Number
Description
090-0168-02
Amplifier, Standard Power Level 1, for High Capacity Repeater
090-0168-02L
Amplifier, Standard Power Level 1, for Low ~ Medium Capacity Repeater
090-0168-04
Amplifier, Higher Power Level 2, for High Capacity Repeater
090-0168-04L
Amplifier, Higher Power Level 2, for Low ~ Medium Capacity Repeater
090-0286-02
DC-DC Converter Assembly, +24VDC to +11.5VDC
175-0028-01
Fuse, Blade Type, 3-Ampere, DC
550-0156-01
Manual, Operations, RF-7000E Microwave RF Repeater
Table 9 Alarm System Options, High Capacity Repeaters
Standard Assembly
Part Number
Description
RMAS-120-01
900-0782-01
Standard Telemetry, 1+0, for 1 ~ 2-amplifier repeaters
RMAS-120-02
900-0782-02
Standard Telemetry, 1+1, for 3 ~ 4-amplifier repeaters
RMAS-120-81
900-0782-81
UHF Telemetry, 1+0, for 1 ~ 2-amplifier repeaters
RMAS-120-82
900-0782-82
UHF Telemetry, 1+1, for 3 ~ 4-amplifier repeaters
RMAS-120-83
900-0782-83
UHF Te2ANL, 1+0, for 1 ~ 2-amplifier repeaters
Table 10 Alarm System Options, Low ~ Medium Capacity Repeaters
Standard Assembly
Part Number
Description
RMAS-120L-01
900-0782-01L
Standard Telemetry, 1+0, for 1 ~ 2-amplifier repeaters
RMAS-120L-02
900-0782-02L
Standard Telemetry, 1+1, for 3 ~ 4-amplifier repeaters
RMAS-120L-81
900-0782-81L
UHF Telemetry, 1+0, for 1 ~ 2-amplifier repeaters
RMAS-120L-82
900-0782-82L
UHF Telemetry, 1+1, for 3 ~ 4-amplifier repeaters
RMAS-120L-83
900-0782-83L
UHF Te2ANL, 1+0, for 1 ~ 2-amplifier repeaters
UHF Radio Kits including antennas, feedlines and lightning protection are available from Peninsula Engineering
Solutions.
Alarm closures can be adapted to SNMP reporting over IP networks using Peninsula Engineering’s SNMP-SL10
equipment.
Contact Peninsula Engineering Solutions for details and assistance.