Penguin P-HF Series Скачать руководство пользователя страница 4

P-7 1/2A-HF thru P-15A-HF

DISASSEMBLY 

1.  Unscrew and remove discharge piping. Remove the six (6) snap ring bolts (

Item 16).

 

Now the snap ring 

(Item 12)

 can be removed using a screwdriver or a pair of pliers.

2.  With a rubber mallet, gently hit the back of the suction casing (Item 10).

  Alternating blows from one side to the other until the suction casing comes off. 

  Suction casing O-ring can easily be replaced.

3.  Unscrew the impeller nut using a 3/4 inch socket wrench in a counterclockwise rotation. 

Impeller nut O-ring can be replaced.

4.  Thread a 3/4-10UNC bolt into the hole in the center of the impeller eye. Holding the 

impeller, using an appropriate wrench turn the bolt clockwise until the impeller slips off 

the shaft. 

ASSEMBLY

1.  Unscrew the fan cover screws and remove the fan, fan cover, and drip shield assembly. 

In order for the motor to stand on end, the fan shaft must be placed in a hole deep 

enough for it to sit flat on the end bell. With the motor in a vertical position, shaft 

upwards, place the four motor spacers over the motor bolt holes. Place housing over 

shaft, lining up motor bolt holes in the mounting bracket with holes in the motor. Be 

sure the slinger is properly in place. Screw the motor bolts into the holes beneath the 

mounting bracket in a diagonal sequence. 

 

Be sure motor screws are tight.

2.  Using loctite or other type of thread-locker, secure key into keyway on shaft. Insert the 

impeller into the housing. Rotate to engage key and slide or lightly tap into place until 

it bottoms out. Do not hammer the impeller and sleeve down on the shaft. Screw the 

impeller nut clockwise holding impeller. Be sure impeller nut O-ring is properly in place. 

After hand-tight, turn with wrench 180 degrees (10-15 inch lbs). 

 

DO NOT OVERTIGHTEN.

4.  Place the pump upright resting on the motor. Look down into the housing and, 

while rotating the impeller, check to see that the impeller is centered. The impeller 

must not be touching the side of the housing.

5.  Lubricate support casing and casing O-ring. Be sure casing O-ring is properly in 

place. Slide suction casing over support casing, lining up timing marks to assure 

proper fit. Using a soft mallet, tap suction casing down onto support casing until 

snap ring groove is exposed. Line up through holes in snap ring with the threaded 

holes in the support casing by rotating the snap ring clockwise. Insert and tighten 

the six (6) snap ring screws.

    I n s t a l l a t i o n   &   M a i n t e n a n c e

P E N G U I N

P E N G U I N

14

15

10

8

12

16

9

7

x

13

3/4-10 UNC Bolt

To help in disassembly, note 4

Fan Cover 

w/Drip Shield

External Fan

Motor

Assembly - Step 1

Motor Parts

Pad with hole used for 

protection.

Fan Shaft

Отзывы: