background image

- 7 - 

The box contents above are for reference only and the actual items shall depend on the product package you obtain. 
The box contents are subject to change without notice. 

The motherboard image is for reference only. 

Relion 2908GT Chassis Manual 

 

Box Contents 

Relion 2908GT System 

Содержание Relion 2908GT

Страница 1: ...Relion 2908GT Power E cient Intel based HPC Server Designed for Next generation Datacenters Technical Guide Rev 1 0 PENGUIN COMPUTING www penguincomputing com 1 888 PENGUIN 736 4846 twitter PenguinHPC...

Страница 2: ...tures in this manual may be made by Penguin Computing without prior notice No part of this manual may be reproduced copied translated transmitted or published in any form or by any means without Pengu...

Страница 3: ...ill NOT be covered in this generic service guide In suchcases please contact your regional offices or the responsible personnel channel to provide youwith further technical details 2 Please note WHEN...

Страница 4: ...emory Configuration 21 2 5 2 Installing a Memory 22 2 6 Installing the PCI Expansion Card 23 2 6 1 Installing Add on Card MNXE2 MEZZ_2 Optional 28 2 6 2 Installing Add on Card MLIZS MEZZ_2 Optional 29...

Страница 5: ...nabling 113 5 5 2 3 5 2 4 5 2 5 5 2 6 5 2 7 5 2 8 5 9 Network Stack 63 CSM Configuration 64 Post Report Configuration 6 6 Trusted Computing 67 USB Configuration 68 Chipset Configuration 69 SIO Configu...

Страница 6: ...5 1 Secure Boot menu 121 5 5 1 1 Key Management 122 6 Boot Menu 124 7Save Exit Menu 126 5 8 BIOS POST Codes 128 5 9 BIOS POST Beep code 132 5 9 1 PEI Beep Codes 132 5 9 2 DEX Beep Codes 132 5 10 BIOS...

Страница 7: ...ence only and the actual items shall depend on the product package you obtain The box contents are subject to change without notice The motherboard image is for reference only Relion 2908GT Chassis Ma...

Страница 8: ...cover these openings Make sure youprovide adequate space around the system for ventilation when you set up your work area Never insertobjects of any kind into the ventilation openings To avoid electri...

Страница 9: ...t may cause undesired opera tion Canadian Department of Communications Compliance Statement This digital apparatus does not exceed the Class A limits for radio noise emissions from digitalapparatus as...

Страница 10: ...tails of environmentally safe recycling w When your electrical or electronic equipment is no longer useful to you take it back to your local or regional waste collection administration for recycling w...

Страница 11: ...ep your hands dry and first touch a metal object to eliminate static electricity Prior to installing the motherboard please have it on top of an antistatic pad or within an electrostatic shielding con...

Страница 12: ...t Expansion Slot 8 x PCI Express x16 slots running at x16 Gen3 PCIE_1 PCIE_2 PCIE_3 PCIE_4 1 x PCI Express x16 slot running at x8 Gen3 MEZZ_1 Proprietary slot 1 x PCI Express x8 slot running at x8 Gen...

Страница 13: ...LAN1 LAN2 Front Panel LED Buttons 1 x Power button LED 1 x ID button LED 1 x Reset button 2 x LAN LED 1 x HDD Status LED 1 x System LED I O Controller ASPEED AST2400 BMC chip Hardware Monitor System...

Страница 14: ...Hardware Installation 14 Relion 2908GT Chassis Manual 1 3 System Block Diagram...

Страница 15: ...he notches on both sides of the CPU and alignment keys on the CPU socket Apply an even and thin layer of thermal grease on the surface of the CPU Do not turn on the computer if the CPU cooler is not i...

Страница 16: ...you remove or install the system cover Make sure the system is not turned on or connected to AC power Follow these instructions to remove the system cover 1 Loosen and remove the screws securing the...

Страница 17: ...2 Removing and Installing the Fan Duct Follow these instructions to remove install the fan duct 1 Lift up to remove the fan duct 2 To install the fan duct align the fan duct with the guiding groove Pu...

Страница 18: ...from their ports Place the system unit on a flat and stable surface Open the system according to the instructions WARNING Failure to properly turn off the server before you start installing component...

Страница 19: ...ks 1 Apply thermal compound evenly on the top of the CPU 2 Remove the protective cover from the underside of the heat sink 3 Place the heat sink s on top of the CPU and tighten the four positioning sc...

Страница 20: ...Hardware Installation 20 Relion 2908GT Chassis Manual CPU0 CPU1 P N 25ST1 523200 C1R P N 25ST1 443101 T4R...

Страница 21: ...y bandwidth The twenty four DDR4 memory sockets are divided into three channels each channel has two memory sockets as following Channel 1 DIMM_P0_A0 DIMM_P0_A1 DIMM_P0_A2 For pimary CPU DIMM_P1_E0 DI...

Страница 22: ...llow these instructions to install the Memory 1 Insert the DIMM memory module vertically into the DIMM slot and push it down 2 Close the plastic clip at both edges of the DIMM slots to lock the DIMM m...

Страница 23: ...Failure to observe these warnings could result in personal injury or damage to equipment For GPU0 GPU1 GPU6 GPU7 Follow these instructions to install PCI Expansion card 1 Loosen and remove the screws...

Страница 24: ...PCIE_2 Slot 2 2 x 3 Power cable 2 x 4 Power cable For Slot 2 If the GPGPU card supports 225W connect 2 x 4 power cable If the GPGPU card supports 300W connect 2 x 4 and 2 x 3 power cables 3 4 2 x 3 P...

Страница 25: ...PCI cage 2 Pull the two plastic handles to lift up the PCI cage from the system 3 Insert the card into the selected slot and secure the expansion card with screw Make sure that the card is properly s...

Страница 26: ...Hardware Installation 26 Relion 2908GT Chassis Manual 2 1 3 4...

Страница 27: ...e If the GPGPU card supports 300W connect 2 x 4 and 2 x 3 power cables 2 x 3 Power cable 2 x 4 Power cable For Slot 1 Please insert the PCI cage into the selected slot with the correct orientation See...

Страница 28: ...have been disconnected from the server prior to installing a PCI card Failure to observe these warnings could result in personal injury or damage to equipment Follow these instructions to install Add...

Страница 29: ...to installing a PCI card Failure to observe these warnings could result in personal injury or damage to equipment Follow these instructions to install Add on card 1 Remove the rear bracket 2 Attach th...

Страница 30: ...Hardware Installation 30 Relion 2908GT Chassis Manual 3 7 5 6 4...

Страница 31: ...ot fit back into the bay if inserted incorrectly Make sure that the HDD is connected to the HDD connector on the backplane Follow these instructions to install the Hard disk drive 1 Press the release...

Страница 32: ...ed on or connected to the AC power Disconnect all necessary cable connections Failure to observe these warnings could result in personal injury or damage to the equipment GPU56E_FAN GPU12E_FAN GPU56_F...

Страница 33: ...Hardware Installation 33 Relion 2908GT Chassis Manual 3 Airflow direction...

Страница 34: ...N1 SYS_FAN2 Follow these instructions to replace the fan assembly 1 Disconnect fan cable Lift up the fan assembly from the chassis 2 Attach the four rubbers on the system fan 3 Reverse the previous st...

Страница 35: ...hese instructions to replace the fan assembly 1 Loosen and remove the screws securing the fan cage 2 Remove the fan cage out of the system 3 Loosen and remove the screws securing the fan 4 Reverse the...

Страница 36: ...36 Hardware Installation Relion 2908GT Chassis Manual CAUTION To avoid fan cable damages please make sure the fan cables are firmly seated in the groove...

Страница 37: ...he system Follow these instructions to replace the power supply 1 Disconnect all power cables 2 Pull up the power supply handle and press the retaining clip on the right side of the power supply along...

Страница 38: ...1 Front panel LED and buttons 2 System fan GPU78_FAN 3 2 5 inch hard disk drive 1 4 2 5 inch hard disk drive 2 5 2 5 inch hard disk drive 3 6 2 5 inch hard disk drive 4 7 2 5 inch hard disk drive 5 8...

Страница 39: ...switch button 6 Reset button top NMI button buttom 7 System status LED 8 LAN1 Active Link top Speed buttom LEDs 9 Dual 10G SFP LAN port 10 LAN2 Active Link top Speed buttom LEDs 11 10 100 1000 Server...

Страница 40: ...tive N A Off System identification is disabled 3 LAN1 Activity LED Green Solid On Link between system and network Green Blink Network access N A Off Disconnect Idle 4 LAN2 Activity LED Green Solid On...

Страница 41: ...he processor if the multiple bit ECC errors occur which effectively halt the server System 5 Status LED Green Solid On N A Running or normal operation Amber Solid On There is at least one sensor that...

Страница 42: ...frequncy about 2 Hz RAID Color Locate HDD Fault Rebuilding HDD Access HDD Present No Access No RAID configuration via HBA PCH Disk LED LED on Back Panel Green On 1 Off Blink 2 Off Amber Off Off Off O...

Страница 43: ...Installation 43 Relion 2908GT Chassis Manual 3 6 Hard Disk Back Plane Board Jumper Setting SAS_4 7 SAS_0 3 BPB_PWR BPB_CN_2 BPB_CN_2 A_SEL B_SEL A_SEL B_SEL 1 2Close SATA_HDD SATA_HDD 2 3 Close SAS_HD...

Страница 44: ...9 9 9 9 9 3 10 10 3 8 9 9 4 No Suggest Cable No Suggest Cable 1 System main power cable 2 CPU 0 12V power cable 3 CPU 1 12V power cable 4 Front panel cable 5 Mini SAS cable 1 6 Mini SAS cable 2 7 HDD...

Страница 45: ...rts 13 LED_LAN2 LAN2 Active Link top Speed buttom LEDs 14USB3_MLAN 15SSATA_SGP 16 SSATA0 1 2 3 17 FP_1 18 SATA_SGP 19 SATA0 1 2 3 4 5 20 ATX1_2 21 F_USB3 22 ATX1_1 23 DIMM_P0_A0 24 DIMM_P0_A1 25 DIMM_...

Страница 46: ...Select jumper 45 PCIE_2 PCI E slot 2 x16 slot 46 DIMM_P1_F2 Channel 2 slot 2 for secondary CPU 47 DIMM_P1_F1 Channel 2 slot 1 for secondary CPU 48 DIMM_P1_F0 Channel 2 slot 0 for secondary CPU 49 DIMM...

Страница 47: ...ual 70 ME_UPDATE ME update jumper 71 CASE_OPEN Chassis intrusion header 72 MEZZ_1 Mezzine slot 1 x16 slot Proprietary Running at x8 73 LED_BMC BMC firmware readiness LED On BMC frmware is initial Blin...

Страница 48: ...ing BIOS_WP 4 BIOS Write Protect Jumper 1 2 Close Normal operation Default setting 2 3 Close Enable BIOS write protect function BIOS_PWD 5 Clearing Supervisor Password Jumper 1 2 Close Normal operatio...

Страница 49: ...OS do it with caution Inadequate BIOS flashing may result in system malfunction It is recommended that you not alter the default settings unless you need to to prevent system instability or other unex...

Страница 50: ...enabled disabled setup menus Security Change set or disable supervisor and user password Configuration supervisor password allows you to restrict access to the system and BIOS Setup A supervisor pass...

Страница 51: ...tup option is displayed on the bottom line of the Main Menu Submenu Help While in a submenu press F1 to display a help screen General Help of function keys available for the menu Press Esc to exit the...

Страница 52: ...e Firmware setup utility SDR Version Display the SDR version information FRU Version Display the FRU version information Processor Information CPU Brand String Max CPU Speed CPU Signature Processors C...

Страница 53: ...Manual Onboard LAN Information LAN1 LAN2 MAC Address Display LAN1 LAN2 MAC address information System Date Set the date following the weekday month day year format System Time Set the system time fol...

Страница 54: ...n 2908GT Chassis Manual 5 2 Advanced Menu The Advanced menu display submenu options for configuring the function of various hardware components Select a submenu item then press Enter to access the rel...

Страница 55: ...55 BIOS Setup Relion 2908GT Chassis Manual 5 2 1 Serial Port Console Redirection...

Страница 56: ...BIOS Setup 56 Relion 2908GT Chassis Manual...

Страница 57: ...Mark parity bit is always 1 Space Parity bit is always 0 Mark and Space Parity do not allow for error detection Options available None Even Odd Mark Space Default setting is None Flow Control Flow con...

Страница 58: ...unctionKey and KeyPad on Putty Options available VT100 LINUX XTERMR6 SCO ESCN VT400 Default setting is VT100 Redirection After BIOS POST Note This option allows user to enable console redirection afte...

Страница 59: ...rd LAN devices and initialize device expansion ROM Options available Enabled Disabled Default setting is Disabled PCI Devices Common Settings PCI Latency Timer Value to be programmed into PCI Latency...

Страница 60: ...upport If system has SR IOV capable PCIe Devices this option enables or disables Single Root IO Virtualization Support Options available Enabled Disabled Default setting is Disabled PCI Express Settin...

Страница 61: ...Options available Enabled Disabled Default setting is Enabled Maximum Playload Set maximum playload for PCI Express Device or allow system BIOS to select the value Options available Auto 128 Bytes 256...

Страница 62: ...Training bit in Link Status register Press keys to increase or decrease the desired values Value rang is from 10 to 10000 us Unpopulated Links When this item is set to Disable Link the system will op...

Страница 63: ...ult setting is Disabled Ipv4 PXE Support Note Enable Disable Ipv4 PXE feature Options available Enabled DIsabled Default setting is Enabled Ipv6 PXE Support Note Enable Disable Ipv6 PXE feature Option...

Страница 64: ...services Always Do not allow disabling GA20 this option is useful when any RT code is executed above 1MB Options available Upon Request Always Default setting is Upon Request Option ROM Messages Optio...

Страница 65: ...ntrols the execution UEFI and Legacy Storage OpROM Options available Do not launch UEFI Legacy Default setting is Legacy Video Controls the execution UEFI and Legacy Video OpROM Options available Do n...

Страница 66: ...908GT Chassis Manual 5 2 5 Post Report Configuration Post Report Configuration Error Message Report Post Error Message Enable Disable Info Error Message support Options available Enabled Disabled Defa...

Страница 67: ...al 5 2 6 Trusted Computing Configuration Security Device Support Select Enabled to activate TPM support feature Options available Enabled Disabled Default setting is Disabled Current Status Informatio...

Страница 68: ...fault setting is Enabled EHCI Hand off Enable Disable EHCI USB 2 0 Hand off function Options available Enabled Disabled Default setting is Disabled USB Mass Storage Driver Support Note Enable Disable...

Страница 69: ...tate prior to shutdown When set to Stay Off the system remains off after power shutdown Options available Last State Stay Off Power On The default setting depends on the BMC setting Deep Sleep EuP Ena...

Страница 70: ...BIOS Setup 70 Relion 2908GT Chassis Manual 5 9 SIO Configuration...

Страница 71: ...items Serial Port 1 Configuration Use This Device When enabled allows you to configure the serial port 1 settings When set to Disabled displays no configuration for the serial port Options available...

Страница 72: ...erial port 2 settings When set to Disabled displays no configuration for the serial port Options available Enabled Disabled Default setting is Enabled Logical Device Settings Current Display the Seria...

Страница 73: ...5 2 10 iSCSI Configuration iSCSI Initiator Name Add an Attempts Press Enter for configuration of advanced items Delete Attempts Press Enter for configuration of advanced items Change Attempt Order Pre...

Страница 74: ...tel RC Setup Menu Intel RC Setup menu displays submenu options for configuring the function of North Bridge and South Bridge Select a submenu item then press Enter to access the related submenu screen...

Страница 75: ...75 BIOS Setup Relion 2908GT Chassis Manual 5 3 1 Processor Configuration...

Страница 76: ...ble Disable Intel Trusted Execution Technology support function Options available Enabled Disabled Default setting is Disabled VMX Vanderpool Technology Enable Disable Vanderpool Technology This will...

Страница 77: ...Prefetch Delay Options available Disabled 8 16 24 32 40 48 56 64 72 80 88 96 104 112 Default setting is 32 X2APIC Options available Enabled Disabled Default setting is Disabled AES NI Enable Disable A...

Страница 78: ...BIOS Setup 78 Relion 2908GT Chassis Manual 5 3 1 1 Pre Socket Configuration...

Страница 79: ...is Manual CPU Socket 0 1 Configuration Press Enter for configuration of advanced items Cores Enabled for CPU socket 0 1 Number of Cores to enable 0 means all cores 14 Cores is available Press the nume...

Страница 80: ...ent Custom Default setting is Custom Config TDP Options available Enabled Disabled Default setting is Enabled Config TDP Level Options available Nominal Default setting is Nominal CPU P State Control...

Страница 81: ...ailable Enabled Disabled Default setting is Enabled P state coordination In HW_ALL mode the processor hardware is responsible for coordinating the P state among logical processors dependencies The OS...

Страница 82: ...ult setting is C6 non Retention state CPU C3 C6 Report Allows you to determine whether to let the CPU enter C3 C6 mode in system halt state When enabled the CPU core frequency and voltage will be redu...

Страница 83: ...etup Relion 2908GT Chassis Manual 5 3 2 3 CPU T State Control ACPI T States Enable Disable CPU throttling by OS Thorttling reduces power comsumption Options available Enabled Disabled Default setting...

Страница 84: ...Manual 5 3 3 Common RefCode Configuration Common RefCode Configuration Isoc Mode Options available Enabled Disabled Default setting is Disabled Numa Non Uniform Memory Access Options available Enabled...

Страница 85: ...85 BIOS Setup Relion 2908GT Chassis Manual 5 3 4 QPI Configuration...

Страница 86: ...on Press Enter for configuration of advanced items QPI Status Press Enter to view QPI status Link Speed Mode Options available Slow Fast Default setting is Fast Link Frequency Select Options available...

Страница 87: ...333 1400 1600 1800 1867 2000 2133 Default setting is Auto ECC Support Options available Auto Disabled Enabled Default setting is Auto Rank Margin Tool Options available Auto Disabled Enabled Default s...

Страница 88: ...BIOS Setup 88 Relion 2908GT Chassis Manual Memory RAS Configuration Press Enter for configuration of advanced items...

Страница 89: ...89 BIOS Setup Relion 2908GT Chassis Manual 5 3 5 1 Memory Topology...

Страница 90: ...emory Thermal Set Throttling Configure Thermal Throttling Mode Select OLTT or CLTT mode Options available Disabled OLTT CLTT Default setting is CLTT MEMHOT Throttling Mode Options available Disabled O...

Страница 91: ...a chunk of local memory below 4GB Options available Disabled Enabled Default setting is Disabled Channel Interleaving Options available Auto 1 way Interleave 2 way Interleave 3 way Interleave 4 way I...

Страница 92: ...s set to enabled Sparing will be selected Options available Disable Mirror Lockstep Mode Default setting is Disabled Lockstep x4 DIMMs Options available Auto Disabled Enabled Default setting is Disabl...

Страница 93: ...on EV DFX Features Set this option to allow DFX Lock Bits to remain clear Options available Enabled Disabled Default setting is Disabled IOAT Configuration Press Enter for configuration of advanced it...

Страница 94: ...iguration Enable IOAT Control to enable disable IOAT Intel I O Acceleration Technology device Options available Enabled Disabled Default setting is Disabled No Snoop Enable Disable PCI Express Device...

Страница 95: ...for Directed I O VT d Enable Disable Intel VT for Directed I O VT d support function Options available Enabled Disabled Default setting is Enabled Interrupt Remapping Enable Disable interrupt remappin...

Страница 96: ...l 5 3 7 PCH Configuration PCH Configuration PCH Devices Press Enter for configuration of advanced items PCH SATA Configuration Press Enter for configuration of advanced items USB Configuration Press E...

Страница 97: ...97 BIOS Setup Relion 2908GT Chassis Manual 5 3 7 1 PCH Devices PCH CRID Enable Disable Intel Compatible Revision ID Options available Enabled Disabled Default setting is Disabled...

Страница 98: ...BIOS Setup 98 Relion 2908GT Chassis Manual 5 3 7 2 PCH sSATA Configuration...

Страница 99: ...You will be allows access the RAID setup utility at boot time ACHI Mode When set to AHCI the SATA controller enables its AHCI functionality Then the RAID function is disabled and cannot be access the...

Страница 100: ...hard disk that are installed in the computer System will automatically detect HDD type Port 0 1 2 3 Enable Disable Port 0 1 2 3 device Options available Enabled Disabled Default setting is Enabled Hot...

Страница 101: ...908GT Chassis Manual 5 3 7 2 1 SATA Mode Options When SATA Type is set to IDE AHCI Mode SATA LED locate When this option is enabled LED SGPIO hardware is attached Options available Enabled Disabled De...

Страница 102: ...Intel Rapid Recovery Technology support function Options available Enabled Disabled Default setting is Enabled RAID Option ROM UI banner Options available Enabled Disabled Default setting is Enabled...

Страница 103: ...BIOS Setup 103 Relion 2908GT Chassis Manual 5 3 7 3 PCH SATA Configuration...

Страница 104: ...e This is not allowed to access RAID setup utility RAID Mode When set to RAID the SATA controllerenables both its RAID and AHCI functions You will be allows access the RAID setup utility at boot time...

Страница 105: ...ategory identifies sSATA type of hard disk that are installed in the computer System will automatically detect HDD type Port 0 1 2 3 4 5 Enable Disable Port 0 1 2 3 device Options available Enabled Di...

Страница 106: ...908GT Chassis Manual 5 3 7 3 1 SATA Mode Options When SATA Type is set to IDE AHCI Mode SATA LED locate When this option is enabled LED SGPIO hardware is attached Options available Enabled Disabled De...

Страница 107: ...e Intel Rapid Recovery Technology support function Options available Enabled Disabled Default setting is Enabled RAID Option ROM UI banner Options available Enabled Disabled Default setting is Enabled...

Страница 108: ...ndition Precondition work on USB host conteoller and root ports for faster enumeration Options available Enabled Disabled Default setting is Disabled xHCI Mode Enable Disable xHCI USB 3 0 support func...

Страница 109: ...Relion 2908GT Chassis Manual 5 3 8 Miscellaneous Configuration Miscellaneous Configuration Active Video Select active Video type Options available Onboard Device Offboard Device Default setting is Of...

Страница 110: ...Recovery Firmware Version Display Recovery Firmware Version information ME Firmware Features Display ME Firmware features information ME Firmware Status 1 2 Display ME Firmware status information Cur...

Страница 111: ...abled Default setting is Enabled S W Error Injection Support Enable Disable software injection error logging function Options available Enabled Disabled Default setting is Enabled Whea Settings Press...

Страница 112: ...2 BIOS Setup Relion 2908GT Chassis Manual 5 3 10 1 Whea Setting WHEA Support Windows Hardware Error Architecture Enable Disable WHEA Support Options available Enabled Disabled Default setting is Enabl...

Страница 113: ...3 10 2 Memory Error Enabling Memory Error Enabling Un Correctable Errors disable Memory Options available Enabled Disabled Default setting is Disabled Memory corrected Errors enabling Options availabl...

Страница 114: ...114 BIOS Setup Relion 2908GT Chassis Manual 5 3 10 3 PCI PCI Error Enabling PCI Ex Error Enable Options available Yes No Default setting is No...

Страница 115: ...m is configurable when FRB 2 Timer is set to Enabled OS Watchdog Timer Enable Disable OS Watchdog Timer function Options available Enabled Disabled Default setting is Disabled OS Wtd Timer Timeout Con...

Страница 116: ...2908GT Chassis Manual System Event Log Press Enter for configuration of advanced items View FRU Information Press Enter to view the advanced items BMC network configuration Press Enter for configurat...

Страница 117: ...sing SEL Choose options for erasing SEL Options available No Yes On next reset Yes On every reset Default setting is No When SEL is Full Choose options for reactions to a full SEL Options available Do...

Страница 118: ...etup Relion 2908GT Chassis Manual 5 4 2 View FRU Information The FRU page is a simple display page for basic system ID information as well as System product information Items on this window are non co...

Страница 119: ...ly DHCP Do nothing option willnot modify any BMC network parameters during BIOS phase Options available Unspecified Static DynamicBmcDhcp Default setting is Unspecified Static Station IP Address Displ...

Страница 120: ...access and change all settings in the Setup Utility User Password Entering this password will restrict a user s access to the Setup menus To enable or disable this field a Administrator Password must...

Страница 121: ...led Secure Boot Mode Secure Boot requires all the applications that are running during the booting process to be pre signed with valid digital certificates This way the system knows all the files bein...

Страница 122: ...All Factory Default Keys Press Enter to install all factory default keys Save All Secure Boot Variables Press Enter to save all Secure Boot Variables Platform Key PK Display the status of Platform Key...

Страница 123: ...lete DB Press Enter to delete the db from your system Set new DB Press Enter to configure a new db Append aVar to DB Press Enter to load additional db from a storage devices Forbidden Signature Databa...

Страница 124: ...means indefinite waiting Press the numberic keys to input the desired value Bootup NumLock State Enable or Disable Bootup NumLock function Options available On Off Default setting is On Quiet Boot Ena...

Страница 125: ...BIOS Setup 125 Relion 2908GT Chassis Manual Hard Drive BBS Priorities Press Enter to configure the boot priority...

Страница 126: ...S setup Options available Yes No Save Options Save Changes Saves changes made in the BIOS setup Options available Yes No Discard Changes Discards changes made and close the BIOS setup Options availabl...

Страница 127: ...BIOS Setup Relion 2908GT Chassis Manual Boot Override Press Enter to configure the device as the boot up drive UEFI Built in in EFI Shell Press Enter on this item to Launch EFI Shell from filesystem d...

Страница 128: ...e 0x30 PEI_MEMORY_INSTALLED 0x31 PEI_CPU_INIT 0x32 PEI_CPU_CACHE_INIT 0x33 PEI_CPU_BSP_SELECT 0x34 PEI_CPU_AP_INIT 0x35 PEI_CPU_SMM_INIT 0x36 PEI_MEM_NB_INIT 0x37 reserved for NB 0x38 0x3A PEI_MEM_SB_...

Страница 129: ...1 DXE_PCI_BUS_BEGIN 0x92 DXE_PCI_BUS_HPC_INIT 0x93 DXE_PCI_BUS_ENUM 0x94 DXE_PCI_BUS_REQUEST_RESOURCES 0x95 DXE_PCI_BUS_ASSIGN_RESOURCES 0x96 DXE_CON_OUT_CONNECT 0x97 DXE_CON_IN_CONNECT 0x98 DXE_SIO_I...

Страница 130: ...PEI_MEMORY_INVALID_SPEED 0x50 PEI_MEMORY_SPD_FAIL 0x51 PEI_MEMORY_INVALID_SIZE 0x52 PEI_MEMORY_MISMATCH 0x52 PEI_MEMORY_NOT_DETECTED 0x53 PEI_MEMORY_NONE_USEFUL 0x53 PEI_MEMORY_ERROR 0x54 PEI_MEMORY_...

Страница 131: ...0xEF DXE_STATUS_CODE DXE_CPU_ERROR 0xD0 DXE_NB_ERROR 0xD1 DXE_SB_ERROR 0xD2 DXE_ARCH_PROTOCOL_NOT_AVAILABLE 0xD3 DXE_PCI_BUS_OUT_OF_RESOURCES 0xD4 DXE_LEGACY_OPROM_NO_SPACE 0xD5 DXE_NO_CON_OUT 0xD6 D...

Страница 132: ...e in PEI Core called twice 2 Recovery started 3 DXEIPL was not found 3 DXE Core Firmware Volume was not found 4 Recovery failed 4 S3 Resume failed 7 Reset PPI is not available of Beeps Description 1 I...

Страница 133: ...n embedded recovery technique In the event that the BIOS becomes corrupt the boot block can be used to restore the BIOS to a working state To restore your BIOS please follow the instructions listed be...

Отзывы: