PenBarry ZQ110L-GPE Скачать руководство пользователя страница 12

Page 12

WARNING

 

Before servicing or cleaning unit, 

switch power off at service panel and lock the service 
disconnecting means to prevent power from being 
switched on accidentally. When the service disconnecting 
means cannot be locked, securely fasten a prominent 
warning device, such as a tag, to the service panel. 

Operation

To Turn Fan ON

Turn the master switch ON.
It is normal for this ventilation fan to take approximately 5 
seconds to start running after it is turned on.
•  Fan will run at the certified airflow rate if the mode 

select switch is ON.

•  Fan will run at the user-adjustable airflow rate if the 

mode select switch is OFF.

To Use Fan Time Delay Airflow Rate Change

1.  Turn the master switch ON.
2.  Turn the mode select switch ON - fan will run at the 

certified airflow rate.

3.  When the mode select switch is turned OFF, fan will 

continue to run at the certified airflow rate until the 

user-adjustable time delay has elapsed, and then will 

automatically change to the user-adjustable airflow rate.

To Set the User-Adjustable Airflow Rate*

Using a small, flat-blade screwdriver, carefully rotate the 

CFM adjustment until the arrow points to the desired 

airflow rate.

To Set the User-Adjustable Time Delay*

Using a small, flat-blade screwdriver, carefully rotate the 

TIME adjustment until the arrow points to the desired time 

delay, shown in minutes.

*  The user-adjustable controls are located in one corner 

of the Fan Housing, behind the Grille.

To Turn Fan OFF

Turn the master switch OFF. 

To Operate Lights

The fan and light can be operated independently, using 
separate switches. The light may be operated with a 
dimmer switch. See wiring diagrams.

Cleaning and Maintenance

To Clean

For quiet and efficient operation, long life and attractive 

appearance, remove Grille and vacuum interior of unit 

with a dusting brush attachment.  
The Motor is permanently lubricated and never needs 

oiling. If the motor bearings are making excessive or 

unusual noises, replace the Control Assembly and Motor.

Troubleshooting

Symptom: The fan does not run. 

•  Check for an open fuse or circuit breaker in the 

building’s service panel. 

•  Check that the two (2) plug-in connections for the Motor 

and the Control are seated firmly in place. 

•  Check that the Blower Wheel spins freely.

Symptom: The fan runs erratically. 

•  Check that the Blower Wheel is firmly attached to the 

Motor shaft and both spin freely. 

Symptom: The fan seems noisy. 

•  Check that the back draft damper in the fan’s Duct 

Connector pivots freely. Screws used to attach the duct 

to the Duct Connector may be preventing the damper 

from opening. 

•  Check that the back draft damper in the wall or roof cap 

pivots freely. These dampers are sometimes mistakenly 

painted shut or obstructed by bird and insect debris.

Symptom: The fan does not properly ventilate the room.

•  For spot ventilation, turn both the master switch and the 

mode select switch ON to enable the fan to run at the 

certified airflow rate. 

•  For spot ventilation followed by continuous ventilation, 

increase the “TIME” setting of the user-adjustable time 

delay. 

•  For continuous ventilation, increase the “CFM” setting of 

the user-adjustable airflow rate. 

          

ZQ80L User-adjustable controls

 

          

ZQ110L User-adjustable controls

 

CAUTION

IN ORDER TO PREVENT MOTOR/CONTROL DAMAGE:

DO NOT remove motor plug to stop spinning motor.
Power must be disconnected (see WARNING at top left of 

this page) before motor plug is removed or inserted into 

control assembly.

 

1100453A

PennBarry | 605 Shiloh Rd. | Plano, TX 75074 | 972.212.4700 | 

www.pennbarry.com

TM

Содержание ZQ110L-GPE

Страница 1: ... SAVE THESE INSTRUCTIONS Installer leave this guide with homeowner Easy installation in both new construction and retrofit Table of Contents Warnings and Cautions 2 Typical Installation 2 New Construction Installation 3 Retrofit Installation 7 Operation 12 Cleaning and Maintenance 12 Troubleshooting 12 TM ...

Страница 2: ...CI Ground Fault Circuit Interrupter protected branch circuit 9 This unit must be grounded Typical Installation CAUTION 1 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 This product is designed for installation in ceilings up to a 12 12 pitch 45 degree angle Duct connector must point up DO NOT MOUNT THIS PRODUCT IN A WALL 3 To avoid motor bearin...

Страница 3: ... bit Phillips screwdriver Flathead screwdriver Pliers Wire insulation stripper Wire cutter Materials needed 6 round metal ducting recommended for best performance Use of other ducting is acceptable but may impact performance Roof cap or wall cap built in damper recommended Tape to seal duct connections Electrical wiring and supplies per local code requirements 1 Remove Packaging 2 Install Mounting...

Страница 4: ...on Housing between joists and crimp channel on both sides of Mounting Frame to lock Housing in place Do not crimp Housing Screws from Parts Bag Top and bottom flanges go outside Housing Insert tab into slot inside Housing Screw from Parts Bag 6 to 4 Reducer provided in select models Tape Tape Tape 6 Ducting 4 Ducting snap ...

Страница 5: ... MODE SELECT SWITCH LIGHT LIGHT WITH DIMMER SWITCH New Construction Installation 5 Connect Wires and Install Knockout Plate Run 120VAC electrical wiring to the installation location Use proper UL approved connectors to secure wiring to the Knockout Plate provided in Parts Bag Connect wires as shown in wiring diagram Screw from Parts Bag Attach cable clamps to Knockout Plate Knockout Plate mounts t...

Страница 6: ...move before installing Grille Install ceiling material Cut out around Housing CAUTION If the blower was unplugged power must be disconnected see page 2 WARNING item 2 before inserting motor plugs into control assembly IN ORDER TO PREVENT MOTOR CONTROL DAMAGE 1 2 3 1 See Page 12 for Operations Cleaning and Maintenance and Troubleshooting ...

Страница 7: ...o make sure it is not damaged If any damage is found DO NOT CONTINUE INSTALLATION of this product Contact a qualified person s for repair Remove Instruction Sheet Punch out Mask from packaging See Step 12 1 Remove Packaging 2 Switch Off Power 4 Examine Wiring 3 Enlarge Ceiling Opening and Remove Existing Fan Ruler Pencil Drywall saw Claw hammer or pry bar Utility knife Materials needed Tape to sea...

Страница 8: ...trofit Installation 5 Remove Blower Assembly 6 Remove Wiring Panel 7 Insert Mounting Frame Both sides Set aside Blower Assembly Set aside Wiring Panel Set aside screw Bend up four tabs Remove screws from Mounting Frame and set aside ...

Страница 9: ...xisting wiring into Housing as it is inserted into Mounting Frame Pull existing ductwork into Housing Insert tab into slot inside Housing 10 Attach Ducting and Duct Connector 8 Secure Mounting Frame 9 Snap in Housing snap 6 to 4 Reducer provided in select models Tape Tape Tape 6 Ducting 4 Ducting ...

Страница 10: ... in wiring diagram Attach cable clamps to Knockout Plate Knockout Plate mounts to inside of Housing and may be oriented as desired LINE IN GRD WHT BLK GRD WHT WHT WHT BLK BLK BLU RED BLK LIGHT SWITCH FAN SWITCH FAN LIGHT UNIT SWITCH BOX RED WHT 14 2 14 3 MANUAL ON DIMMER SWITCH LINE IN GRD WHT BLK GRD WHT WHT WHT BLK BLK BLU RED BLK MASTER ON OFF SWITCH FAN UNIT SWITCH BOX RED WHT 14 2 14 3 FAN SW...

Страница 11: ...pairs are needed place Mask in Housing after Blower Assembly is secured See New Construction Installation Step 6 Remove Mask before installing Grille Screws from Parts Bag CAUTION Power must be disconnected see page 2 WARNING item 2 before inserting motor plugs into control assembly IN ORDER TO PREVENT MOTOR CONTROL DAMAGE ...

Страница 12: ...ning and Maintenance To Clean For quiet and efficient operation long life and attractive appearance remove Grille and vacuum interior of unit with a dusting brush attachment The Motor is permanently lubricated and never needs oiling If the motor bearings are making excessive or unusual noises replace the Control Assembly and Motor Troubleshooting Symptom The fan does not run Check for an open fuse...