background image

Models ZQ80L-GPE 

n

 ZQ110L-GPE

Multi-Speed Ventilation 

Fan with Dimmable Light

INSTALLATION GUIDE

READ AND SAVE THESE INSTRUCTIONS 

Installer: leave this guide with homeowner.

Easy installation in both  
new construction and retrofit

Table of Contents

Warnings and Cautions 

2

Typical Installation 

2

New Construction Installation 

3

Retrofit Installation 

7

Operation 12
Cleaning and Maintenance 

12

Troubleshooting 12

TM

Содержание ZQ110L-GPE

Страница 1: ... SAVE THESE INSTRUCTIONS Installer leave this guide with homeowner Easy installation in both new construction and retrofit Table of Contents Warnings and Cautions 2 Typical Installation 2 New Construction Installation 3 Retrofit Installation 7 Operation 12 Cleaning and Maintenance 12 Troubleshooting 12 TM ...

Страница 2: ...CI Ground Fault Circuit Interrupter protected branch circuit 9 This unit must be grounded Typical Installation CAUTION 1 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 This product is designed for installation in ceilings up to a 12 12 pitch 45 degree angle Duct connector must point up DO NOT MOUNT THIS PRODUCT IN A WALL 3 To avoid motor bearin...

Страница 3: ... bit Phillips screwdriver Flathead screwdriver Pliers Wire insulation stripper Wire cutter Materials needed 6 round metal ducting recommended for best performance Use of other ducting is acceptable but may impact performance Roof cap or wall cap built in damper recommended Tape to seal duct connections Electrical wiring and supplies per local code requirements 1 Remove Packaging 2 Install Mounting...

Страница 4: ...on Housing between joists and crimp channel on both sides of Mounting Frame to lock Housing in place Do not crimp Housing Screws from Parts Bag Top and bottom flanges go outside Housing Insert tab into slot inside Housing Screw from Parts Bag 6 to 4 Reducer provided in select models Tape Tape Tape 6 Ducting 4 Ducting snap ...

Страница 5: ... MODE SELECT SWITCH LIGHT LIGHT WITH DIMMER SWITCH New Construction Installation 5 Connect Wires and Install Knockout Plate Run 120VAC electrical wiring to the installation location Use proper UL approved connectors to secure wiring to the Knockout Plate provided in Parts Bag Connect wires as shown in wiring diagram Screw from Parts Bag Attach cable clamps to Knockout Plate Knockout Plate mounts t...

Страница 6: ...move before installing Grille Install ceiling material Cut out around Housing CAUTION If the blower was unplugged power must be disconnected see page 2 WARNING item 2 before inserting motor plugs into control assembly IN ORDER TO PREVENT MOTOR CONTROL DAMAGE 1 2 3 1 See Page 12 for Operations Cleaning and Maintenance and Troubleshooting ...

Страница 7: ...o make sure it is not damaged If any damage is found DO NOT CONTINUE INSTALLATION of this product Contact a qualified person s for repair Remove Instruction Sheet Punch out Mask from packaging See Step 12 1 Remove Packaging 2 Switch Off Power 4 Examine Wiring 3 Enlarge Ceiling Opening and Remove Existing Fan Ruler Pencil Drywall saw Claw hammer or pry bar Utility knife Materials needed Tape to sea...

Страница 8: ...trofit Installation 5 Remove Blower Assembly 6 Remove Wiring Panel 7 Insert Mounting Frame Both sides Set aside Blower Assembly Set aside Wiring Panel Set aside screw Bend up four tabs Remove screws from Mounting Frame and set aside ...

Страница 9: ...xisting wiring into Housing as it is inserted into Mounting Frame Pull existing ductwork into Housing Insert tab into slot inside Housing 10 Attach Ducting and Duct Connector 8 Secure Mounting Frame 9 Snap in Housing snap 6 to 4 Reducer provided in select models Tape Tape Tape 6 Ducting 4 Ducting ...

Страница 10: ... in wiring diagram Attach cable clamps to Knockout Plate Knockout Plate mounts to inside of Housing and may be oriented as desired LINE IN GRD WHT BLK GRD WHT WHT WHT BLK BLK BLU RED BLK LIGHT SWITCH FAN SWITCH FAN LIGHT UNIT SWITCH BOX RED WHT 14 2 14 3 MANUAL ON DIMMER SWITCH LINE IN GRD WHT BLK GRD WHT WHT WHT BLK BLK BLU RED BLK MASTER ON OFF SWITCH FAN UNIT SWITCH BOX RED WHT 14 2 14 3 FAN SW...

Страница 11: ...pairs are needed place Mask in Housing after Blower Assembly is secured See New Construction Installation Step 6 Remove Mask before installing Grille Screws from Parts Bag CAUTION Power must be disconnected see page 2 WARNING item 2 before inserting motor plugs into control assembly IN ORDER TO PREVENT MOTOR CONTROL DAMAGE ...

Страница 12: ...ning and Maintenance To Clean For quiet and efficient operation long life and attractive appearance remove Grille and vacuum interior of unit with a dusting brush attachment The Motor is permanently lubricated and never needs oiling If the motor bearings are making excessive or unusual noises replace the Control Assembly and Motor Troubleshooting Symptom The fan does not run Check for an open fuse...

Отзывы: