![PEM SprayWand P-500 Скачать руководство пользователя страница 35](http://html.mh-extra.com/html/pem/spraywand-p-500/spraywand-p-500_manual_1523646035.webp)
33 |
P a g e
Figure 20:
Removing the manifold head
Caution
: When sliding the head from the crankcase, be careful
not to damage the plungers.
3.
The V-packing assemblies may come off with the head. If not, slide them
off and examine the ceramic plungers. Their surface should be smooth
and not scored or pitted. Clean them if necessary, and replace them if
they are damaged as follows:
Replacing plungers
1.
Using a 10-mm socket, remove the ceramic plunger and plunger
retainer from the piston rod (see Figure 21).
Figure 21:
Removing plunger
2.
If the barrier slinger or keyhole washer comes off with the plunger,
replace them before installing a new plunger.
3.
Separate the plunger retainer from the plunger.
4.
Install a new seal washer on the plunger retainer. Use a small dab of
grease on the outside of the seal washer to ensure better installation.
5.
Carefully press the plunger retainer into the new plunger.
Содержание SprayWand P-500
Страница 2: ......
Страница 37: ...35 P a g e Figure 23 Pump exploded view ...
Страница 52: ...50 P a g e Figure 27 Electrical diagram ...