![Pelton & Crane Solaris Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/pelton-and-crane/solaris/solaris_use-and-care-manual_1523577017.webp)
17
042281 R03
Door Hinge adjustment
The doors are adjusted at the factory so the doors open and
close properly. However, an occasional adjustment may be
required over a period of usage.
Unsnap hinge cover from hinge. Using a green handle screw
driver from grass or a #2 posi-drive
driver only
, adjust doors
as follows:
Screw
1
will move the door SIDE to SIDE. Clockwise pulls
the hinge in, lowering the far corner of the door. Counter-
clockwise pushes the door outward, raising the far corner of
the door.
Screw
2
allows the door to be moved UP & DOWN.
Screw
3
will move the door TOWARD and AWAY from the
module.
Drawer Adjustment
The drawers are adjusted at the factory. However, an
occasional adjustment may be required over a period of
usage. These adjusting screws are located in each front
corner of the drawer.
Using a #2 posi-drive
driver only
, adjust doors as follows:
1.
Vertical adjustment
: Lightly loosen screws (
2
)
counterclockwise, adjust screw (
1
) up or down, tighten
screws (
2
).
2.
Horizontal Adjustment
:
Lightly loosen screws (
2
),
adjust front to desired position, tighten screws (
2
).
3.
angle Correction
: Loosen top screw or bottom screw (
2
)
according to your needs. Push angle correction wedge
(type 6155) in between, tighten screws (
2
) and tear off
wedge. Angle correction ±1.
1.
2.
3.