background image

#500964-001 - 

Product Manual: Model #SB-SM1 Fall Arrest Tower Base

 - Revision 01 - Date: 03-04-2010

Page 7

2.0 - Introduction & Product Information

MODEL:____________________________________________

Serial Number :_______________________________________ 

Date of Manufacture (DOM):____________________________

Congratulations on your choice of a 

Pelsue Model #SB-SM1 4-Arm Manway Mount 

to compliment your fall arrest 

system. This equipment has been designed and manufactured to exceed fall arrest requirements and regulations in 

order to meet the needs of the discriminating operator.

Safe, efficient and trouble-free operation and maintenance of the system requires that anyone who will be operating, 

maintaining, or inspecting the equipment, read, understand and follow all of the operation, safety, maintenance, and 

inspection instructions contained within this manual. This manual covers the Pelsue Model #SB-SM1 4-Arm Manway 

Mount. Use the Table of Contents as a guide to find specific information.

keep this manual available for future reference and for usage as a tool in the instruction of new operators. Establish a 

regular training program for all operators. Establish a regular maintenance and inspection program to keep the equip-

ment in top condition.

This product is a part of a complete Fall Arrest system. 

The user must read, understand and follow the instruc-

tions contained in this manual for each component or 

total  system  before  using  this  equipment.  Establish 

an appropriate training, maintenance and inspection 

program for your people and the equipment. Failure 

to  follow  these  instructions  could  result  in  serious 

injury or death.

2.1 - Serial Number

Product Serial Number

Always give your dealer the serial number of your Pelsue Fall 

Arrest product when ordering parts or requesting service or 

other information.
The serial number decal is permanently embossed with a 

serial number.  The serial number decal will appear as shown 

in 

Figure 2a at the right and is located on the top face of the  

base plate (see 

Figure 2b).  A space has been provided below 

for the recording of the serial number for future reference.

Figure 2a:

Serial Number Decal

#SB-SM1

Figure 2b:

 

Serial Number Decal Location

SERIAL

NUMBER

LOCATION

Содержание 500964-001

Страница 1: ... SB SM1 Fall Arrest Tower Base 4 Arm Manway Mount T A Pelsue Company 2500 South Tejon Street Englewood Colorado USA 80110 Tel 800 525 8460 or 303 936 7432 Fax 303 934 5581 Internet www pelsue com Email sales pelsue com ISO 9001 Certified ...

Страница 2: ... 500964 001 Product Manual Model SB SM1 Fall Arrest Tower Base Revision 01 Date 03 04 2010 Page 2 Page 2 ...

Страница 3: ... continuing reputation for excellence in the production of fine products for a broad spectrum of industry throughout the world Now in our second generation of family direction continued commitment to innovation and quality makes Pelsue a leading source of equipment for many types of confined spaces We specialize in safety retrieval fall arrest ventilation cable placing splicing and maintenance nat...

Страница 4: ...ormation 7 2 1 Serial Number 3 0 Configuration Assembly 8 4 0 Safety 9 4 1 Warning Statement 4 2 Safety Alert Symbol 4 3 General Safety Information 4 4 Operating Safety 4 5 Maintenance Safety 4 6 New Operator Safety Information 5 0 Product Operation 12 5 1 Product Description Capabilities 5 2 Product Installation Set Up 6 0 Maintenance Inspection 16 6 1 Maintenance 6 2 Inspection 6 3 Inspection Lo...

Страница 5: ...r satisfaction is one of the differentiators that sets you apart from the pack and yields a competitive advantage Therefore we will support total customer satisfaction by implementing the ISO 9001 Quality System and providing the necessary atmosphere and training to nurture this concept throughout our organization We will make every business decisionas though the quality of the part or service pro...

Страница 6: ...e of failure T A Pelsue Company s obligation hereun der shall be limited to the repair or replacement of the product or component as set forth above and shall not include any liability whatsoever for damages caused by such failure including but not limited to consequential or incidental damages flowing from use or lack of use of product Any replacement repair modification installation or other ser...

Страница 7: ...ilable for future reference and for usage as a tool in the instruction of new operators Establish a regular training program for all operators Establish a regular maintenance and inspection program to keep the equip ment in top condition This product is a part of a complete Fall Arrest system The user must read understand and follow the instruc tions contained in this manual for each component or ...

Страница 8: ...ct inspect all of the components for damage If damage to any of the components is discovered DO NOT USE THE PRODUCT Alert the shipping carrier immediately of the damage to the shipment 1 Ensure that the product has been shipped with all the necessary components and is in working order Refer to Fig 3a Refer to parts list above if replacement parts are required Replacement parts can be ordered from ...

Страница 9: ...rt of your safety program Be certain that everyone operating this equipment is familiar with the procedures recommended and follows safety precautions Remember most accidents can be prevented Do not risk injury or death by ignoring good safety practices System owners must give operating instructions to operators or employees before allowing them to use the equipment and at least annually thereafte...

Страница 10: ...ow how to use it 5 Provide a fire extinguisher for use in case of an accident Store in a highly visible place 6 Install and properly secure all guards and shields before operating 7 Wear appropriate protective gear This list includes but is not limited to A hard hat Protective shoes with slip resistant soles Heavy gloves Protective clothing Face Protection 8 Review and follow the Pre Operation Che...

Страница 11: ...anders and the area around the work site Untrained operators are not qualified to operate the equipment Many features incorporated into this equipment are the result of suggestions made by customers like you Read this manual carefully to learn how to operate install the equipment safely and as intended By following the operating instructions in conjunction with a good maintenance program your prod...

Страница 12: ...cessory The rating of a complete fall arrest system can only be rated to the capabilities of its lowest rated component WARNING The user must ensure that the manway to which the SB SM1 is attached is capable of withstanding all of the loads imparted to it by the device when proof loaded There is a limitless variety of manways and addressing each potential scenario is beyond the scope of this manua...

Страница 13: ...actures b Ensure that all product rating warning labels are clear and legible c Check that the arms pivot freely and that the slider blocks are able to slide throughout the arms interference of the slider blocks can be indicative of a defect d All hardware has not been damaged and is in working condition 5 1 Product Description Capabilities continued 5 2 Product Installation Set up Prior to Operat...

Страница 14: ...ting base of the SB SM1 is as close to the center of the manway as possible e Tighten all hardware to standard dry torques according to the size of the mounting hardware WARNING Mounting hardware must be greater or equal to 1 2 in diameter f Check to see and ensure that the arms of the manway mount sit flush to the manway cover and all hardware is tightened 5 2 Product Installation Set up continue...

Страница 15: ... systems when placed in a vertical position f Utilize the installed fall arrest tower within the limits of and according to the instructions provided within the Model FT C70 fall arrest tower s product manual Figure 5 2h SB SM1 FT C70 Completely Installed Figure 5 2f SB SM1 FT C70 Installation WARNING The FT C70 Fall Arrest Tower utilized in conjunction with the SB SM1 4 Arm Manway Mount must be i...

Страница 16: ... to all threads in order to extend the working life of these components 3 Complete Inspection Perform a thorough inspection paying attention to the bullet points provided within section 6 2 Record results and keep documentation A log has been provided in section 6 3 specifically for the recording of the dates results of annual system inspections Periodic Factory Service Inspection It is recommende...

Страница 17: ... If there is any uncertainty with regards to cracks contact the Pelsue service department for assistance and or recommenda tions Ensure that the sections of the device can freely move and be adjusted as intended without interference Binding or interference of any kind may be indicative of structural damage and must be cause for further inspection 4 Slider blocks Ensure that when the slider blocks ...

Страница 18: ...rms Mounting Blocks Notes Inspector print sign Inspector print sign Inspector print sign Inspector print sign Inspector print sign Inspector print sign Inspector print sign Inspector print sign Place a check in the box if item is acceptable place an x X in the box if item requires maintenance or repair Model Number Serial Number Date Purchased SB SM1 ...

Страница 19: ... sales pelsue com Prior to storage the product should be thoroughly inspected and maintained Repair or replace any worn or damaged components to prevent any unnecessary down time at the next use Follow this procedure 1 Thoroughly clean the entire unit using a mild soap on the frame and labels 2 Perform a complete inspection of the unit and document the results prior to storage 3 Ensure that the un...

Страница 20: ...ISO 9001 Certified T A Pelsue Company 2500 South Tejon Street Englewood Colorado USA 80110 Toll free 800 525 8460 or 303 936 7432 Fax 303 934 5581 Internet www pelsue com Email sales pelsue com ...

Отзывы: