26
7081-148H
www.pelprostoves.com
Feed Rates 1 & 2
Operation Instructions
OPERATING IN THERMOSTAT ON / OFF
(Flashing 1 & 2)
This also requires purchasing the optional “Wall Thermostat Add-on Kit”
This mode of operation is best suited for those “Take off the Chill” nights of spring,
summer , fall. The thermostat should be set for the desired room temperature. If the room
temperature drops below the level on the thermostat the stove will automatically begin the
start-up cycle, as explained in the manual operation section.
In this mode the life of the IGNITER is reduced and the power consumption will be higher. If
the thermostat calls for heat while the stove is still cooling down, the stove will go through
the START-UP cycle.
TO START
Once this mode has been selected, you simply press the START touch pad to Activate the
stove. Once the start-up cycle is completed the stove run on the pre-selected “HIGH”
(number 2,3 or4) setting, till the temperature is reached.
TO ADJUST HEAT
You can select the HIGH heat output level (2,3 or 4) by pushing the START touch pad, you can also select the FAN setting
you desire. The stove will now go through its normal start up cycle. Once completed the appliance is now in the ON / OFF
mode.
For optimum heat transfer, the FAN setting should be set at LOW or MEDIUM. The appliance will run the FAN at HIGH
speed when needed, automatically.
TO SHUT DOWN
The thermostat will shut the stove down when the desired room temperature is reached. The Feed Rate numbers 1 & 2 will
flash while the appliance is in the OFF part of this mode to give you a visual indication that the appliance is still active and
in the ON / OFF cycle.
HINT:
If you find that the stove turns off and on repeatedly, you may wish to turn the FEED RATE to a lower setting. The lower setting
will provide a more consistent heat output over time, eliminating the need for the thermostat to repeatedly turn the stove off.
HI
MED
LOW
FAN SPEED
OFF
FAN
SPEED
AUGER
CYCLE
FINE TUNE ADJUSTMENTS
1
4
FAN
Increase
Decrease
Understanding the Control
TRIM POTS
(Fine Tune Adjustments) –
Factory Settings
DO NOT ADJUST
unless necessary or directed so by Hearth & Home Technologies Customer Service.
FUEL FEED
rates
at the Lowest (number 1) and highest (number 4) settings can be adjusted by
adjusting the fine tune trim pots located on the control panel. To
raise fuel feed
turn trim pot
counter
clockwise
and to
lower
turn
clockwise
. To assist in knowing what the change is you should note the
amount of time the light on the AUGER CYCLE LED stays OFF.
(Note: The light stays on when ever
the fuel feed motor, AUGER CYCLE, is running).
Lengthening the time this LED stays OFF lowers
the fuel feed and shortening the off-time increases the fuel feed
.
FAN (Combustion) TRIM
;
this trim may be used to raise or lower the amount of air moving
through the burn grate for the cleanest burn,
ONLY
when the control is on the Low Feed Rate (1),
and only after the Air Inlet damper has been set during the High Feed Rate (4)..
Note:
If you attempt to adjust the Fuel Feed Trim Pots, use a small precision screwdriver. The Trim Pots do not
make a full rotation. If using a metal screwdriver, be gentle as the plastic trim pot slot can be damaged or stripped.
AUGER CYCLE
The
AUGER CYCLE
LED indicates when a electrical signal is being sent to the auger motor. It is NOT
used to indicate the actual movement of the auger. When the signal is being sent the LED will be solid
for 3 seconds. When the LED is off no signal is being sent
.
FAN SPEED
(Convection or heating)
The
FAN SPEED
controls the speed of the room air fan. This fan blows room air through the heat
exchange tubes and back into the room. The FAN SPEED has 5 different speeds, these are controlled
by pushing the FAN SPEED touch pad. The Low LED will be solid when on the lowest fan speed, the
LOW & MED will both be solid when the next highest speed is selected and so on. When the
FEED
RATE
is set to a higher position, the
FAN SPEED
should be set higher and visa versa.