background image

Page 10  

Removing Collected Water

There are three ways to remove collected water:

1. Use the bucket

When the unit is off, if the bucket is full, the Full
indicator light will light.

When the unit is on, if the bucket is full, the
compressor and the fan turn off, and the Full
indicator light will light, the digital display shows
P2.

Slowly pull out the bucket. Grip the left and right
handles securely, and carefully pull out straight so
water does not spill. Do not put the bucket on the

floor 

as because the bottom of the bucket is

uneven.

 

Otherwise water may be spilled.

Empty the water and reposition the bucket.

The unit will restart operation when the bucket is
back in place.

1. Pull out the bucket.

2. Hold both sides of the

bucket evenly, and pull
it out from the unit.

3. Pour the water out.

Fig. 5

Fig. 6

NOTES

• When you remove the bucket, do not touch any

parts inside the unit. Doing so may damage the
product.

• Be sure to push the bucket gently all the way into

the unit.

• If the pump hose falls off when you remove the

bucket (see Fig. 7), you must reinstall the pump
hose properly to the unit before replacing the
bucket into the unit (see Fig. 8).

• When the unit is on, if the bucket is removed, the

compressor and the fan turn off, then the unit will
beep 8 times and the digital display shows Eb.

• When the unit is off, if the bucket is removed,

the unit will beep 8 times and the digital display
shows Eb.

Fig. 8

Fig. 7

Pump hose drops

Reinstall pump 
hose properly

Oper

ating

Ins
tructions

Содержание PAD20C1AWT

Страница 1: ...it for future reference The design and specifications are subject to change without prior notice for product improvement Consult with your dealer or manufacturer for details Rated voltage 115V Frequen...

Страница 2: ...product Contact an authorized service technician for repair or maintenance of this unit The unit is not designed to be used by young children or people with reduced physical sensory or mental capabil...

Страница 3: ...ay cause electric shock Do not allow water to enter into electric parts It may cause failure or electric shock Do not use the power outlet if it is loose or damaged It may cause fire and electric shoc...

Страница 4: ...ion to avoid injuries to hand and fingers Clean filter once every two weeks If water enters the unit turn the unit off and disconnect the power contact a qualified service technician Do not place flow...

Страница 5: ...fic to this unit Be sure the unit is properly grounded To minimize shock and fire hazards proper grounding is important The power cord is equipped with a three prong grounding plug for protection agai...

Страница 6: ...er cord buckle into the unit Fig 2 Power cord buckle 1 pc Control panel Panel Water level window Water bucket Water bucket Handle both sides Handle both sides Air outlet grille Air outlet grille Conti...

Страница 7: ...ary slightly Functions will be similar CAUTION Clean your unit occasionally to keep it looking new Be sure to unplug the unit before cleaning to prevent shock or fire hazards When you push the button...

Страница 8: ...n level To exit comfort mode adjust the humidity to desired level FILTER Button This feature is a reminder to clean the Air Filter for more efficient operation The LED light will flash after 250 hours...

Страница 9: ...s illuminate identifying both ON and OFF times are now programmed Turning the unit ON or OFF at any time or adjusting the timer setting to 0 0 will cancel the Timer function When LED display window di...

Страница 10: ...ation when the bucket is back in place 1 Pull out the bucket 2 Hold both sides of the bucket evenly and pull it out from the unit 3 Pour the water out Fig 5 Fig 6 NOTES When you remove the bucket do n...

Страница 11: ...draining to start Fig 10 Fig 9 Remove the plastic cover rotating counter clockwise Drain hose When the continuous draining feature is not being used remove the drain hose from the outlet and dry the w...

Страница 12: ...the following items Cleaning the pump filter Remove the bucket from the unit take out the pump and clean the pump filter See Fig 12 Check if the drain hose is clean and free of debris Empty the water...

Страница 13: ...idential applications only This dehumidifier should not be used for commercial or industrial applications Place the dehumidifier on a smooth level floor strong enough to support the unit with a full b...

Страница 14: ...vacuum cleaner or brush to clean 2 Clean the bucket Every few weeks clean the bucket thoroughly to prevent growth of mold mildew and bacteria Partially fill the bucket with clean water and mild deterg...

Страница 15: ...the dehumidifier can properly function so restart the unit once the room is above that desired temperature There is a water vapor source in the room causing the humidity to constantly increase This w...

Страница 16: ...es not cover the following 1 Failure caused by damage to the unit while in your possession other than damage caused by defect or malfunction by its improper installation or by unreasonable use of the...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...PELONIS...