Troubleshooting the System 

Problem:  

Leaks between cap and bottom of filter housing 

Correction: 

Turn off water supply and turn on drinking water faucet to release pressure in 
system.  Remove bottom of housing.  Clean O-ring groove (located directly 
beneath threads of housing). Lubricate O-ring with silicone grease and replace 
securely into groove.  Screw bottom of housing onto cap and hand-tighten.  DO 
NOT OVER-TIGHTEN.  Turn on water supply and check for leaks 

Problem:  

Leaks on system inlet/outlet connections 

Correction: 

Turn off water supply and turn on drinking water faucet to release pressure in 
system.  Remove tubing from fitting and make sure end of tubing is cut squarely 
and free of burrs.  Reinsert tubing into fitting, making sure to push tubing to a 
hard stop.  Hand-tighten compression nut first, then tighten 1 to 1 1/2 turns for 
new compression nut.  Tighten only 1/2 to 1 turn with wrench for previously 
tightened compression nut.  
NOTE:  If leaks persist, or if there are other leaks in system, turn off water supply. 

Problem: 

Leaks on faucet / tubing connection 

Correction: 

Turn off water supply and turn on drinking water faucet to release pressure in 
system.  Loosen and remove compression nut fitting on faucet stem. Make sure 
tubing is inserted firmly into end of faucet stem, then retighten compression nut 
with fingers until secure.  Turn on saddle valve, and then turn off faucet to check 
for leaks.  
NOTE:  If leaks persist, or if there are other leaks in system, turn off water supply. 

Problem: 

No water or decreased water flow. 

Correction: 

Check flow at faucet. The PDF-1000VF system should fill a gallon jug in 
approximately 2 minutes.  Flow rates will vary with individual household water 
pressure. 

Correction: 

Check filter cartridge installation.  Make certain all filter cartridges are properly 
oriented in filter housings. 

Correction: 

Replace filter cartridges. 

Parts List 

ITEM# 

QTY 

PART# 

DESCRIPTION 

ITEM# 

QTY 

PART# 

DESCRIPTION 

4002991 

MTG BRACKET, 3 HOUSING WHITE 

15 

PDF-VF-R03 

FILTER 

144169-02 

MTG BRACKET, 3 HOUSING WHITE 
(ALTERNATIVE) 

16 

PDF-VF-R02 

 

FILTER

SH244788 

ELBOW, 1/4" NPT X 1/4" QC WH PP 

17 

PDF-VF-R01 

 FILTER 

SH244791 

NIPPLE, MALE HEX 1/4" NPT X 1/4" NPT 

20 

161123 

FILTER TIMER MONITOR, 12 MONTH 

158125 

1/4" #10 SL WHITE WO/PR 12/C 

21 

161125 

INSTRUCTION SHEET, TIME STRIP 

SH143263 

SCREW #6X 1/4" LG PHIL PAN 

22 

0.0240 

RL 

SH144223 

MACHINE TAPE, TEFLON 1/4" WIDE 

42561 

LUBRICANT, SILICONE, PACKET 

25 

1611161 

MANUAL, PELICAN PDF-1000VF 

150539 

WRENCH SW-1A 

26 

10.000 

FT 

SH243244 

TUBE, 1/4" OD WHITE PE 

12 

PW-80-09 

SCREW, #10 - 32 X 3/4" PAN HEAD 

27 

161143 

DM FITTING; 1/4" X 1/4" QC; NPT 

4002987 

VALVE, SADDLE 1/4 COMPRESSION 

24 

N/A 

10 

SH243249 

SCREW #10-12 X 1.5 TYPE A 

32 

0.1250 

FT 

SH243244 

TUBE, 1/4" OD WHITE PE 

11 

C143026 

LOCAL "O-RING" 

33 

0.4583 

FT 

SH243244 

TUBE, 1/4" OD WHITE PE 

13 

701-DBXX

FAUCET 

34 

244985 

INLINE FLOW RESTRICTOR, 0.5 GPM 

14 

161127 

METER, 1800 GALLON, 1/4 NPT 

Содержание PDF-1000VF

Страница 1: ...ed by Pelican Water Systems 3060 Performance Circle Suite 2 DeLand FL 32723 Toll Free 877 842 1635 Rev Date 3 11 2016 Installation and Operation Manual System tested and certified to meet the requirem...

Страница 2: ...place the defective product or part Pelican Water Systems will consider the customer s preference in good faith All claimed defective product must 1 be authorized for return by Pelican Water Systems w...

Страница 3: ...ation source such as contamination by raw sewage Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts System is not intended to convert wastewater o...

Страница 4: ...nstallation on 3 8 inch 10mm cold water line Numbered diagrams correspond with numbered steps Step 1 Installing the Saddle Valve Use of a cordless drill is recommended To protect yourself from serious...

Страница 5: ...washer and lock washer on the threaded shaft e Thread on the lock nut Tighten lock nut by hand until tight Caution Do not over tighten the lock nut Hand tighten only Do not use pliers or wrench to ti...

Страница 6: ...etting the Effective Life Indicator NOTE The effective life indicator is the white dial located on the center of the mounting bracket Each black mark on the dial represents 100 gallons 378 5L a Move t...

Страница 7: ...f household bleach and scrub to disinfect 5 Lubricate O rings with clean silicone grease Insert each O ring in groove and press into place NOTE This step is important to ensure a proper housing seal M...

Страница 8: ...nd then turn off faucet to check for leaks NOTE If leaks persist or if there are other leaks in system turn off water supply Problem No water or decreased water flow Correction Check flow at faucet Th...

Страница 9: ...EXPLODED PARTS VIEW 9...

Страница 10: ......

Страница 11: ......

Отзывы: