Installation
Calcite Tank Installation
Figure 3
Distributor Tube
MENU
SET
1. Level the
Calcite Tank
Notice:
If the tank is not level, lift the tank straight up 6 inches and tap it on the ground until the tank stands
vertical. The bottom of the tank is round and the boot allows the tank to stand upright.
2. Determine the size and material of your incoming water supply line
and choose the
appropriate fittings required to connect it to the Bypass Valve.
CAUTION:
Do not over-tighten any of the fittings during installation.
Table 2: Bypass Valve Fittings
Part
Description
Qty.
1" PVC Tail Adaptor for
Electronic Head Bypass
2
Clip Channel
O-Ring
3.
Remove the gray cap from the top of the
Calcite
T
ank.
4.
Screw the Electronic Head onto the tank hand-tight.
5.
Install the fittings onto the inlet and outlet, following the
labels
on the
H
ead.
6.
Connect the incoming water supply to the fitting on the inlet side of the Bypass Valve.
7.
Connect the outgoing water supply to the outlet side of the Bypass Valve.
8.
Firmly press one end of the
PVC
Tubing Drain Line onto the
Drain Line B
arb, and secure the
other end of the line to a drain.