1. Install bracket to wall using appropriate fasteners (3 qty, 

5/16

” x 2” stainless lag bolts included).

2. Once the bracket is mounted you can now attach your plumbing to the INLET and OUTLET with 1” male threaded adaptions

(not included). (Plumbing a shut off valve prior and a bypass around the unit is recommended).

3. Apply corresponding decals to each of the covers as shown. (Sediment on Inlet side, Chlorine on Outlet side).
4. Unwrap cartridges and insert into each of the housings centering on the stand pipe.
5. Thread housings onto the corresponding covers counter clockwise. Snug housings (Do Not Overtighten).
6. Slowly turn on water main to fill housings.
7. Open the nearest faucet and run water for 10 minutes to expel any

carbon fines.

8. After 10 minutes turn off faucet.
9. Your system is now ready for use.

Installation

Top of Pelican EZ Connect PC-100

Front of Pelican EZ Connect PC-100

WARNING

:

If this or any other system is installed in a metal (conductive) plumbing system, i.e. copper or galvanized metal, the plastic 
components of the system will interrupt the continuity of the plumbing system. As a result any errant electricity from improperly 
grounded appliances downstream or potential galvanic activity in the plumbing system can no longer ground through 
contiguous metal plumbing. Some homes may have been built in accordance with building codes, which actually encouraged 
the grounding of electrical appliances through the plumbing system. Consequently, the installation of a bypass consisting of the 
same material as the existing plumbing, or a grounded “jumper wire” bridging the equipment and reestablishing the contiguous 
conductive nature of the plumbing system must be installed prior to your systems use.

Cartridge Replacement

1. Turn off main water supply
2. Open the nearest faucet (leave open)
3. Apply wrench to housing & turn clockwise to loosen (to the left)
4. Remove and discard old O-ring and cartridge
5. Unwrap and install a new cartridge centering on stand pipe
6. Install a new O-ring lubricated with food grade silicone grease
7. Re-install housing and tighten

(Do not over tighten)

8. Turn main water supply on slowly to allow the

system to fill, the air will expel through the open

faucet

*  When replacing the chlorine cartridge, you will need to run

water at the nearest faucet for 10 minutes to expel any carbon

fines.

9. Close faucet and check for leaks