5. Remove the O-Ring and wipe the groove and O-Ring clean. Lubricate the O-Ring with a coating of
clean silicone grease. Replace O-Ring and press the O-Ring down into the groove with two fingers.
Note: This step is important to ensure the proper filter seal. Make sure the O-Ring is seated level
in the groove. If the O-Ring appears damaged, stretched, or crimped it should be replaced at this
time.
6. Place a new Calcite Cartridge onto the Stand Pipe in the Filter Housing, ensuring the end labeled
“Top End Cap” is facing up.
7. Screw the Filter Housing onto the Housing Cover until hand-tight.
8. Turn on water supply slowly to allow the Calcite Cartridge System to fill with water.
9. Check for leaks.
Pelican