![Pelgrim GVW820 Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/pelgrim/gvw820/gvw820_manual_1522472044.webp)
39
CLEANING/INST
ALLA
TION
■
Remove the microfilter (D) by unscrewing
the bayonet catch.
■
Remove the filter mesh by squeezing the
filter housing (see fig. 13c). Simultaneously,
pull out the filter mesh vertically.
■
Clean filter mesh and filter with a brush
under running water.
■
Reassemble the filter mesh and filter in
reverse order.
Installation
Electrical connection
230 V – 50 Hz
General
If the appliance does not have a connecting
cable and plug, then it may only be connected
to the mains by an approved installer.
Note:
The power rating and required mains voltage
are shown on the rating plate. Connection
should take place according to national and
local regulations.
If the input of the appliance exceeds 3 kW, the
appliance has to be connected to an outlet
with a rated current exceeding 13 Amp.
Technical information
Connected load
kW
see identification
plate
Dimensions:
Max. height
mm
870
Min. height
mm
820
Width
mm
596
Depth
mm
550
Door panel:
Max. height*
mm
600
Min. height
mm
500
Depth
mm
598
Control panel
Max. height
mm
155
Min. height
mm
115
Plinth:
Max. height
mm
170
Min. height
mm
100
* at minimal control panel height
What else you should watch out for
■
Always fit tap, drainage and earthed
plug/wall socket within reach.
■
Make sure that the skirting-board can be
removed. It must be possible to take the
dishwasher out of its recess for
maintenance or repair work.
■
Connect water inlet hose/aquastop to a
self-venting water tap with a 3/4" screw
connection.
Make sure that no dirt remains in a newly-
installed water pipe.
Содержание GVW820