31
CLEANING/INST
ALLA
TION
Fig. 7c
■
Remove the filter group by pulling the
handle (A).
■
Press on the two clips (B) and remove the
filter (C) straight out.
■
Press on the two clips (E) and remove the
filter mesh (D) straight out..
■
Clean filter mesh and filter with a brush
under running water.
■
Reassemble the filter mesh and filter in
reverse order.
Installation
Electrical connection
230 V – 50 Hz
General
When the appliance does not have a
connecting cable and plug, then it may be
connected to the mains only by an approved
installer.
Note:
The power rating and required mains voltage
are shown on the rating plate. Connection
should take place according to national and
local regulations.
If the input of the appliance exceeds 3 kW, the
appliance has to be connected to an outlet
with a rated current exceeding 13 Amp.
Technical information
Connected load
kW
see identification
plate
Dimensions:
Max. height
mm
870
Min. height
mm
820
Width
mm
596
Depth
mm
550
Door panel:
Max. height*
mm
600
Min. height
mm
500
Depth
mm
598
Control panel
Max. height
mm
155
Min. height
mm
115
Plinth:
Max. height
mm
170
Min. height
mm
100
* at minimal control panel height
What else you should watch out for
■
Always fit tap, drainage and earthed
plug/wall socket within reach.
■
Make sure that the skirting-board can be
removed. It must be possible to take the
dishwasher out of its recess for
maintenance or repair work.
D
E