background image

Contact

PELA Tools

 

Solängsvägen 13

 

SE-513 70  Borås

Phone: 033-202650 

E-mail: [email protected]

Environmental protection / 

Scrapping

Recycle any unwanted material, 

 

do not throw it in the household 

 

rubbish. All machines, accessories 

and packaging must be sorted and left 

at a recycling center and disposed 

 

of in an environmentally friendly 

 

manner.

Description

1.  Parts are washed in large closed cabinets, with 

high protection against splashes and odors 

from solvents.

2.  Pneumatic washing gun suitable for fast

 

cleaning.

3.  Extra heating system that delivers max. 

 

50-degree solvent which increases the 

 

efficiency of the purification.

4.  Fluorescent lighting system for clear light.

5.  External air fan provides excellent ventilation.

6.  Washing pressure: 70-120 PSI bar.

7.  Washing circulation flow: 0.8 liters / min.

8.  Working area: 74 * 56 * 45 cm.

9.  Solution amount: 8-14 L. 

10. Air demand: 70-120 PSI bar @ 5CFM.

General safety information

1.  Check that the horizontal deviation of the 

 

workbench is less than a 2 degree angle.

2.  Keep the work area clean. Messy areas and 

benches xan lead to accidents.

3.  Keep children away. All visitors should be kept 

at a safe distance from the work area.

4.  Use the right tools. Do not force the washing 

machine or accessories to do a job for which it 

was not designed.

5.  Equip with our approved hose parts when you 

use organic cleaning solution.

6.  Wear protective gloves. Do not use broken 

gloves.

7.  Disconnect the washing machine from the 

power supply before service and when 

 

changing accessories.

8.  Make sure that the heating switch is ”OFF” 

before starting the machine.

9.  Do not start heating when the volume of 

 

solvent is lower than 8 liters.

10. Do not use if the cabinet door is open.

11. Use only recommended detergent. Not diesel, 

petrol, thinner, degreaser or other unintended 

agent.

12. Do not use solvents whose ignition temperature 

is lower than 120 ° C.

13. Do not use an operating temperature higher 

than 50 degrees celsius.

Содержание 507493

Страница 1: ...Parts washer with heater Verkstadstv tt med v rme Item No 507493...

Страница 2: ...I bar 5CFM Allm n s kerhetsinformation 1 Kontrollera att arbetsb nkens horisontella avvikelse r mindre n 2 graders vinkel 2 H ll arbetsomr det rent R riga omr den och b nkar inbjuder till olyckor 3 H...

Страница 3: ...Styrenhet f r digital temperatur V rme P av kontakt Lufttrycksm tare Str m p av kontakt Luftregulator Reng ringspistol brytare Luft p av brytare L sningmedelslang Snabbkontakt Fast bult Indikator f r...

Страница 4: ...med 4 M12 skruvar och plana brickor 2 Montera benf rst rkningar 22 f r att st dja benen 23 med hj lp av 2 M10 skruvar och plana 3 F st 4 fotkuddar 24 p botten av st dbenen 23 4 V nd p maskinen och st...

Страница 5: ...r ckligt med l snings medel 3 Absorbtionsr ret r blockerat 1 Sl p den 2 L gg till mer l sningsmedel i tanken 3 Kontrollera och reng r absorbtionsr ret Ljuset fungerar inte men fl kten fungerar fortfar...

Страница 6: ...l ktk pa 15 Framd rrst ng 16 Ventilerad fl kt 17 Reng ringspistol 18 Sk p 19 Ryggskydd 20 Sidost d 21 Sidoskydd 22 Benet f rst rker 23 St dben 24 Fotplatta Termostat instruktion 1 Tryck p OK f r att s...

Страница 7: ...esg ovan n mnt direktiv har f ljande harmoniserade standarder anv nts Standard EN 60204 1 2018 Notified body Intertek Certifikatsnummer 211000603HZH V1 Denna produkt var CE m rkt r 2021 Person som r b...

Страница 8: ...nd 70 120 PSI bar 5CFM General safety information 1 Check that the horizontal deviation of the workbench is less than a 2 degree angle 2 Keep the work area clean Messy areas and benches xan lead to ac...

Страница 9: ...her Digital temperature control unit Heat on off contact Air pressure gauge Power on off connector Air regulator Cleaning gun switch Air on off switch Solvent hose Quick contact Fixed bolt Water level...

Страница 10: ...flat washers 2 Install leg reinforcements 22 to support the legs 23 using 2 M10 screws and flat 3 Attach 4 foot pads 24 to the bottom of the support legs 23 4 Turn the machine over and adjust the hei...

Страница 11: ...cient solvent 3 The absorption tube is blocked 1 Turn it on 2 Add more solvent to the tank 3 Check and clean the ab sorption tube The light does not work but the fan still works 1 The light is broken...

Страница 12: ...d 16 Ventilated fan 17 Cleaning gun 18 Cabinet 19 Back protective shield 20 Side support 21 Side protective shield 22 Leg reinforces 23 Support leg 24 Foot pad Thermostat instruction 1 Press OK to sta...

Страница 13: ...following harmonized standards have been applied Standards EN 60204 1 2018 EN 60335 1 2012 A11 2014 A13 2017 A1 2019 A2 2019 A14 2019 Notified body Intertek Certificate number 211000603HZH V1 This pr...

Страница 14: ...Verktygsboden Erfilux AB K llb cksrydsgatan 1 SE 507 42 Bor s Verktygsboden Bor s Sweden 0120504 03...