background image

GB - 1

PEHA Elektro GmbH & Co. KG

Postfach 1727 • D-58467 Lüdenscheid • Tel.: (02351)185-0 • Fax: (02351)27666 • e-mail: [email protected] • Internet: www.peha.de

 

PEHA_M_941_24_EM (Rev05_130308)

126096-04

coDInG swITch

The input module‘s address is set by the coding switch built into the PHC control 

module. The setting of the coding switch is presented in the PHC software under the 

menu item „

Components 

g

 Edit Modules

“.

Make sure that no identical module addresses are given for PHC input modules. 

The setting of the coding switch may be carried out by technicians only. For this the 

PHC module needs to be switched off and it must be ensured that there can be no 

electrical discharge.

currenT consumPTIon

The current consumption of the input module depends on the type and number of the 

connected command devices:

Own consumption: 10 mA

Input with switch:  8 mA

TechnIcaL DaTa

Power supply 

Phc system (Phc bus)

Nom. 24 V DC

21-28 V  DC (ripple voltage 5 %)

own consumption

10-60 mA (after input switching)

number of inputs

16 inputs (

I

0- 

I

15)

Input resistance

1 kΩ

Length of signal line

max. 400m (at d = 0.8 mm)

Input signals

> 40ms

Time for interpreting 

an input signal

The following signals are interpreted:

On  >  0 Sec

On  >  1 Sec

On  >  2 Sec

Off  <  1 Sec

Off  >  1 Sec

contact resistance when 

activating inputs

Max. 33 Ohm (corresponds to < 1V DC at 24 mA)

connection possibilities

2 modular sockets for PHC bus

16  screw terminals for input signals 

I

0-

I

15

8 screw terminals for 0 V

coding

DIP switch, 5-pin (Module address)

ambient temperature

+10° to +50°C

storage temperature

-20° to +60°C

screw terminals

max. 2 x 1,5 mm²

Test specifications

EN 60669-2-1

approbationen

CE   KEMA/KEUR   CEBEC

Protection level

IP 20

Dimensions

Width  = 72 mm

Height = 55 mm

warranTy conDITIons

These operating instructions are an integral part of both the device and our terms of 

warranty. They must be handed over to the user. The technical design of the appliance 

is  subject  to  change  without  prior  notification. 

PEHA

 products are manufactured 

and quality-checked with the latest technology according to applicable national and 

international regulations. Nevertheless, if a product should exhibit a defect, 

PEHA

 

warrants to make remedy as follows (regardless of any claims against the dealer to 

which the end user may be entitled as a result of the sales transaction):

In the event of a justified and properly established claim, 

PEHA

 shall exercise its 

prerogative to either repair or replace the defective device. Further claims or liability 

for consequential damage are explicitly excluded. A justifiable deficiency is deemed to 

exist if the device exhibits a structural, manufacturing, or material defect that makes it 

unusable or substantially impairs its utility at the time it is turned over to the end user. 

The warranty does not apply to natural wear, improper usage, incorrect connection, 

device tampering or the effects of external influences. The warranty period is 24 months 

from the date of purchase by the end user from a dealer and ends not later than 36 

months after the device’s date of manufacture. German law shall be applicable for the 

settlement of warranty claims.

DIsPosaL oF The DevIce

Do not dispose of old devices in the household waste! The device must be 

disposed of in compliance with the laws and standards of the country in which it 

is operated! The device contains electrical components that must be disposed of 

as electronics waste. The enclosure is made from recyclable plastic.

DescrIPTIon

The PHC 940/24 EM input module has 16 inputs 

(

I

0-

I

15)

, which are switched to 

earth (0V) by switches or buttons. The 24 V direct current of the inputs are provided 

by the module. 

All inputs can be used with switches or buttons without feedback signals (LED).

connecTIon DIaGram

On 0 V port (earth) is intended for each 2 

button inputs. The 0 V ports are internally 

connected in the module. It needs to be 

ensured that the button is operated with 

the earth of the module to which they are 

connected.

Please note! 

The buttons are connected with the 24 

V power supply of the PHC system. 

It therefore needs to be ensured that 

no connection is established to 230 

V alternating current circuits. Such a 

connection can make the entire PHC 

system defective.

mounTInG

The installation of the PHC modules may be carried out by authorised technicians only. 

During installation the system‘s electricity has to be switched off. The PHC module is 

designed for mounting on a 35mm top hat rail acc. EN 50022 in  in-/on-wall distribution 

housing. The devices can be mounted directly next to each other.

attention!!

 The PHC modules may 

not

 be employed in connection with devices that 

may endanger people, animals or property when operated.

The following points must be observed:

-  the valid laws, standards and regulations

-  the technical state of the art during installation

-  the PHC manual and the operating instructions of the PHC modules.

-  Operating instructions can only cite general stipulations. These are to be viewed in  

  the context of a specific system.

The following systems may not be switched by Phc output modules:

-  safety switches such as EMERGENCY OFF

-  emergency power supplies

-  fire alarm systems

-  emergency lighting systems

DaTa connecTIon

The connection between PHC control unit and other PHC modules is established by 

the PHC bus line and the modular connectors of the modules. The module connectors 

are switched parallel in the modules (except in the PHC power supply unit) and 

therefore freely selectable as in- or output. Thus the PHC module can be positioned 

anywhere in the data line.

A PHC bus line of 30 cm length is included with every PHC module. It is needed for 

connecting a neighbouring module or for connecting a module in the next distributor 

row. The modules are supplied with voltage by the bus line. Power needs to be 

switched off before disconnecting the bus line.

941_24EM - GEHB - 01

Eingangsmodul 24V f. Schalter

Gehäusebeschriftung

1
1

8 x Input

0 0V 1

2 0V 3

4 0V 5 6 0V 7

I

I

I

I

I

I

I

I

8 x Input

8 0V 9 10 0V 11

12

14

0V

0V

13

15

I

I I

I

I

I

I

I

Art. Nr.: 941/24 EM

16 Eingänge

Schaltschwelle < 1V/30mA
ohne Ansteuerung von Rückmelde-LEDs

Eingangsmodul 24V
für Schalter oder Taster

CEBEC

29

F

ü

r

d

ie

se

Z

e

ic

h

n

u

n

g

b

e

a

n

sp

ru

ch

e

n

w

ir

a

lle

U

rh

e

b

e

r-

re

ch

te

,

a

u

ch

r

d

e

n

F

a

ll

d

e

r

P

a

te

n

ta

n

m

e

ld

u

n

g

o

d

e

r

G

e

-

b

ra

u

ch

sm

u

st

e

re

in

tr

a

g

u

n

g

.

V

e

rv

ie

lf

ä

lt

ig

u

n

g

o

d

e

r

W

e

it

e

r-

g

a

b

e

a

n

D

ri

tt

e

n

u

rn

a

ch

u

n

se

re

rv

o

rh

e

ri

g

e

n

Z

u

st

im

m

u

n

g

.

Infratec

Datentechnik GmbH

D a t u m

N o r m

Ä n d e r u n g

Name

Dateiname:

Blatt

Bl.

Urspr.:

Format DIN A4H

Datum

Zust.

G e p r.

Bearb.

N a m e

941/24 EM

16 Inputs 30mA/1V DC for Switches or Pushbuttons

PHC System

Datum

Name

Kniedruck und Geräteaufkleber

Bearb.

24.01.12

Kai Imorde

Gepr.
Norm

 

 

Gevener Weg 38 · 58809 Neuenrade 

Ein Betrieb der Unternehmensgruppe 

 

PHC Input Module 941/24 EM

Seite

1

Zust.

Änderung

Datum Name

Urspr.: Format DIN A4

Dateiname: GAK 941 24 EM (Rev01_120124)

Für 

diese 

Z

eichnu

ng 

beanspruchen

 

wir alle 

Urheberrechte, 

auch für den F

all 

der P

atentanmeldung 

oder Gebr

auchsmus

-

tereintr

agung. V

ervielfältigung 

oder 

W

eitergabe an 

Dritte 

nur 

nach 

unserer 

vorherigen 

Zustimmung.

coding switch 

module address

InsTaLLaTIon anD oPeraTInG InsTrucTIon
Phc input modul 941/24 em

16 inputs (24 v Dc)
941/24 em

Gb

Отзывы: