PeerlessBoilers WBV-03-060 Скачать руководство пользователя страница 1

WBV/WV

Boilers

Series

Oil

I n s t a l l a t i o n ,
O p e r a t i o n   &
M a i n t e n a n c e
M a n u a l

As an ENERGY STAR

®

Partner, PB Heat, LLC has determined that 

this product meets the ENERGY STAR guidelines for energy efficiency.

Plastic Jacket

Содержание WBV-03-060

Страница 1: ...WV Boilers Series Oil Installation Operation Maintenance Manual As an ENERGY STAR Partner PB Heat LLC has determined that this product meets the ENERGY STAR guidelines for energy efficiency Plastic Ja...

Страница 2: ...COVERPLATE 9 G CONTROLS 9 4 BURNER SETUP BOILER OPERATION 11 A BURNER INSTALLATION 11 B BURNER START UP AND ADJUSTMENT 11 C CHECK BOILER CONTROLS 11 D PURGE AIR FROM THE SYSTEM WATER BOILERS ONLY 12 5...

Страница 3: ...is equipped with an override which is provided primarily to permit the use of an external energy management system that serves the same function THIS OVERRIDE MUST NOT BE USED UNLESS AT LEAST ONE OF T...

Страница 4: ...is boiler must be installed by a qualified contractor The boiler warranty can be voided if the boiler is not installed maintained and serviced correctly Figure 1 1 Appliance Installation Clearances Th...

Страница 5: ...system and installation must be in accordance with the current edition of the American National Standard ANSI NFPA 211 Chimneys Fireplaces Vents and Solid Fuel Burning Appliances or applicable provisi...

Страница 6: ...ler system operation in general You can also use this survey to locate system problems which will have to be corrected To obtain copies of these Surveys contact your PB Heat representative or download...

Страница 7: ...e installed as a rear flue outlet unit or a top flue outlet unit Packaged WBV 03 and WBV 04 boiler models are shipped as rear flue outlet and may be converted The WV 05 boiler model is only available...

Страница 8: ...er forced circulation However there is no minimum water flow rate for this boiler B SYSTEM COMPONENTS Figure 3 1 shows the symbol key for the piping diagrams in this section The following are brief de...

Страница 9: ...he boiler pressure relief valve is shipped separately for field installation On the WBV WV boiler this can be piped into the connection provided next to the boiler supply outlet connection or alternat...

Страница 10: ...8 WATER PIPING Figure 3 3 Recommended Water Piping...

Страница 11: ...he cooling coil in the airstream F TANKLESS HEATER OR COVERPLATE 1 If a tankless coil is used item 9 install as pictured On water boilers install in opening in front section 2 If not using a tankless...

Страница 12: ...10 Figure 3 7 Tankless Coil Piping Water Boiler WATER PIPING Figure 3 6 WBV WV Piped with a Chiller...

Страница 13: ...down the thermostat and moving the main boiler service switch to the off position 4 See burner manufacturer s manual for further information regarding the burner C CHECK BOILER CONTROLS 1 Limit and O...

Страница 14: ...purging Pumps will hold air in the eye of the impeller 2 Allow the system to reach 180 F and use manual vents if installed to remove any remaining air Watch the pressure gauge as the system approaches...

Страница 15: ...BURNER SPECIFICATIONS Boiler Model No Burner Model No Burner Series Nozzle Size Pump Pressure Start Up Settings Turbulator Air Damper WBV 03 060 F3 Series 40 0 50 90 B 145 PSI 0 0 2 9 WBV 03 085 F5 S...

Страница 16: ...ective devices shall not be wired in a grounded line B WIRING 1 See Section 4 for mounting burner 2 For complete information on servicing and adjustment of controls refer to the attached control speci...

Страница 17: ...15 ELECTRICAL Figure 4 1 Water Boilers Beckett 7600A Limit Control Figure 4 1a Beckett AquaSmart 7600A Limit Control Wiring Details...

Страница 18: ...16 Figure 4 2 Water Boilers Hydrolevel 3250 Limit Control ELECTRICAL Figure 4 2a Hydrolevel HydroStat 3250 Limit Control Wiring Details...

Страница 19: ...de adequate ventilation Wear a NIOSH MSHA approved respirator Wear long sleeved loose fitting clothing and gloves to prevent skin contact Wear eye goggles Minimize airborne dust prior to handling and...

Страница 20: ...fety relief valve Boiler temperature should never be higher than 250 F 4 Check for water leaks in boiler and system piping C WEEKLY MAINTENANCE WITH BOILER OPERATING 1 Flush float type low water cut o...

Страница 21: ...n the city water inlet valve to assure required system pressure usually about 12 psi Close the inlet valve if it is necessary to open the inlet water valve frequently a substantial leak may be the cau...

Страница 22: ...oiler Dimensions Water Boiler Boiler Model Number Jacket Depth A Jacket Width B Jacket Height C Rear of Jacket to c l of Vent D Vent Size Diameter E WBV 03 085 110 18 3 8 23 5 8 39 1 4 7 6 WBV 04 125...

Страница 23: ...ating Capacity and Annual Fuel Utilization Efficiency AFUE ratings are based on U S Government tests with 13 CO2 and 0 02 w c draft over fire Before purchasing this appliance read important informatio...

Страница 24: ...arts are available from your local PB Heat LLC distributor or from Parts To Your Door at 1 610 916 5380 www partstoyourdoor com Note Remember to include the boiler model number and serial number when...

Страница 25: ...less Coil WV 05 Water 90534 10 Flue Collector Plate Blanket Seal 90999 11 Flue Collector Cover Plate WBV 03 90565 Flue Collector Cover Plate WBV 04 90566 11A Top Outlet Flue Collector Plate WV 05 9056...

Страница 26: ...Operation Maintenance Manual TO THE INSTALLER This manual is the property of the owner and must be affixed near the boiler for future reference TO THE OWNER This boiler should be inspected annually by...

Отзывы: