background image

4 of 9

ISSUED: 08-02-05  SHEET #: 202-9010-1

Installation to Single Wood Stud Wall

1

Use a stud finder to locate the edges of the stud. Use of an edge-to-edge stud finder is highly recommended. Based
on its edges, draw a vertical line down the stud’s center. Place wall plate (

AA

) on wall as a template, making sure

that the three mounting holes are over the stud centerline. The top mounting hole should be 2.5" above the desired
screen center as shown in figure 1.1. Level plate, and mark the center of the three holes. Drill three 5/32" (4 mm) dia.
holes 2-1/2" (65 mm) deep. Make sure that the wall plate is level, secure it using three #14 x 2.5" wood screws (

CC

)

as shown in figure 1.2.

Skip to step 2 on page 7.

• Installer must verify that the supporting surface will safely support the combined weight of all attached equipment and

hardware.

WARNING

• Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the

screws, greatly reducing their holding power.

• Never tighten in excess of 80 in. • lb (9 N.M.).

• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud finder is

highly recommended.

• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Installers

are responsible to provide hardware for other types of mounting situations.

WARNING

CC

AA

fig. 1.1

fig. 1.2

2.5"

(64 mm)

CS = center of screen

CS

Содержание SMART MOUNT SF 16D

Страница 1: ... 8870 Fax 708 865 2941 www peerlessmounts com ISSUED 08 02 05 SHEET 202 9010 1 Installation and Assembly Dedicated Flat Wall Mount for Flat Panel Screens Models SF 16D Features Ultra slim design holds the screen flat against the wall Integrated security features provide effective theft deterrence ...

Страница 2: ...ccessories Metal Stud Fastener Kit ACC 415 Do not begin to install your Peerless product until you have read and understood the instructions and warnings contained in this Installation Sheet If you have any questions regarding any of the instructions or warnings please call Peerless customer care at 1 800 729 0307 This product should only be installed by a qualified professional Make sure that the...

Страница 3: ...iption Qty Part AA wall plate 1 200 1797 BB interface plate 1 200 0860 CC 14 x 2 5 wood screw 4 5S1 015 C03 DD Alligator anchor 4 590 0097 EE M10 x 1 5 x 15 mm socket head screw 4 520 9262 FF 4 mm security allen wrench 1 560 1146 Parts List AA EE FF BB ...

Страница 4: ...sing three 14 x 2 5 wood screws CC as shown in figure 1 2 Skip to step 2 on page 7 Installer must verify that the supporting surface will safely support the combined weight of all attached equipment and hardware WARNING Tighten wood screws so that wall plate is firmly attached but do not overtighten Overtightening can damage the screws greatly reducing their holding power Never tighten in excess o...

Страница 5: ...all plate is level secure it using four 14 x 2 5 wood screws CC as shown in figure 1 4 Skip to step 2 on page 7 Installer must verify that the supporting surface will safely support the combined weight of all attached equipment and hardware WARNING Tighten wood screws so that wall plate is firmly attached but do not overtighten Overtightening can damage the screws greatly reducing their holding po...

Страница 6: ...vity Concrete must be 2000 psi density minimum Lighter density concrete may not hold concrete anchor Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard ware and components WARNING CUTAWAY VIEW INCORRECT concrete surface 1 3 2 DD Drill holes and insert anchors DD CORRECT Place plate AA over anchors DD and secure with screws CC Tighten ...

Страница 7: ... screws EE as shown in figures 2 1 portrait or 2 2 landscape 2 Installing Interface Bracket to PLP Adapter Plate Tighten screws so adapter brackets are firmly attached Do not tighten with excessive force Overtightening can cause stress damage to screws greatly reducing their holding power and possibly causing screw heads to become detached Tighten to 40 in lb 4 5 N M maximum torque WARNING fig 2 1...

Страница 8: ...ate as shown in figures 2 3 portrait or 2 4 landscape 2 Installing Interface Bracket to LC Adapter Plate Tighten screws so adapter brackets are firmly attached Do not tighten with excessive force Overtightening can cause stress damage to screws greatly reducing their holding power and possibly causing screw heads to become detached Tighten to 40 in lb 4 5 N M maximum torque WARNING fig 2 3 portrai...

Страница 9: ...horizontally if desired Note To lock the screen down tighten security screw to wall plate using security allen wrench as shown in detail 1 To remove screen from mount loosen security screw swing screen away from mount and lift screen off of mount 3 Always use an assistant or mechanical lifting equipment to safely lift and position the plasma television WARNING DETAIL 1 SECURITY SCREW 2005PeerlessI...

Отзывы: