ISSUED: 03-30-07  SHEET #: 124-9052-1

Installation to Solid Concrete Column

1

Make sure that column plate (A) is level, use it as a
template to mark four mounting holes. Drill four 1/4"
(6 mm) dia. holes to a minimum depth of 2-1/2"
(64 mm). Insert anchors (B) in holes flush with
column as shown (right). Place column plate over
anchors and secure with four #14 x 2-1/2" screws
(C). Level, then tighten all fasteners.

• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.

• Make sure that the column will safely support the combined load of the equipment and all attached hardware and

components.

WARNING

CUT

A

W

A

Y

 VIEW

INCORRECT

concrete
surface

1

3

2

Drill holes and insert anchors (B).

CORRECT

Place plate (A)

 

over anchors (B) and secure with screws (C).

column

plate

plaster/

dry wall

concrete

column

plate

concrete

plaster/

dry wall

• Always attach concrete expansion anchors directly to

load-bearing concrete.

• Never attach concrete expansion anchors to concrete

covered with plaster, drywall, or other finishing mate-
rial. If mounting to concrete surfaces covered with a
finishing surface is unavoidable, the finishing surface
must be counterbored as shown below. Be sure
concrete anchors do not pull away from concrete
when tightening screws. If plaster/drywall is thicker
than 5/8", custom fasteners must be supplied by
installer.

WARNING

A

• Tighten screws so that column plate is firmly attached,

but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.

• Never tighten in excess of 80 in. • lb (9 N.M.).

WARNING

B

C

B

Note: Two Alligator® anchors and two #14 x 2-1/2
hex head wood screws from ST 630 fastener pack are
required to complete assembly.

B

A

C

concrete
column

Содержание MIS374

Страница 1: ... North Ave Melrose Park IL 60160 800 729 0307 or 708 865 8870 Fax 708 865 2941 www peerlessmounts com ISSUED 03 30 07 SHEET 124 9052 1 Installation and Assembly 20 Column Tilt Mount for 10 24 LCD Flat Panel Screens Using ST 630 Model MIS374 ...

Страница 2: ...fied professional Make sure that the column will safely support the combined load of the equipment and all attached hardware and components Never exceed the Maximum Load Capacity of 80 lb 36 3 kg Always use an assistant or mechanical lifting equipment to safely lift and position equipment Tighten screws firmly but do not overtighten Overtightening can damage the items greatly reducing their holdin...

Страница 3: ...cure with screws C column plate plaster drywall concrete column plate concrete plaster drywall Always attach concrete expansion anchors directly to load bearing concrete Never attach concrete expansion anchors to concrete covered with plaster drywall or other finishing mate rial If mounting to concrete surfaces covered with a finishing surface is unavoidable the finishing surface must be counterbo...

Страница 4: ...ips screws D two split washers F and two flat washers E 2 E F D A TILT ASSEMBLY Refer to Attaching Adapter Plate to Flat Panel Screen section of ST 630 instruction manual to complete assembly 2007 Peerless Industries Inc All rights reserved Allotherbrandandproductnamesaretrademarksorregisteredtrademarksoftheirrespectiveowners Installation of ST 630 Tilt Assembly ...

Отзывы: