PEERLESS COL 510P Скачать руководство пользователя страница 2

ISSUED: 11-24-99   SHEET #: 200-9192-2   07-23-04

Visit the Peerless Web Site at www.peerlessindustries.com

For customer service call 1-800-729-0307 or 708-865-8870.

2 of 6

O

A

F

E

D

H

A

C

B

Attach column bushing (

O

) to support column (

A

) using two

screws (

T

). The screws control swivel action, so do not

tighten until product is fully assembled and flat panel is in
viewing position.

Insert rubber grommet (

G

) into hole in bottom of support

column (

A

).

At all three support legs attach support column (

A

) to base

plate (

B

) using fastener plates (

C

), M10-1.5 x 20 mm

socket head screws (

D

), lock washers (

E

), and flat

washers (

F

). 

Note:

 Leave screws slightly loose until all are

attached, then tighten all screws securely.

Attach base plate (

B

) to concrete floor. Use six Rawl-Bolt

concrete expansion anchors (

H

). Drill 3/8" dia. holes to a

minimum depth of 2".

G

T

• Flat panel weight is restricted to a maximum of 150 lb

(68 kg). Interfacing flat panel into electrical system at
installation site must conform to local electrical codes
governing such installations and be done by a qualified
electrician / electrical contractor.

• Installer must verify that mounting surface will safely

support the combined weight of all attached equipment
and hardware.

WARNING

• For attachment to concrete floor only! All six concrete

expansion anchors must be used.

• Tighten to 420 IN • LB (47.6 N.M.) torque.

WARNING

Содержание COL 510P

Страница 1: ...94 1 adapter mount M 200 1093 1 swivel bracket N 200 1517 1 neck tube O 590 1111 1 column bushing P 520 9263 16 M10 x 1 5 x 15 mm penta pin screw Q 530 9310 2 3 8 x 16 nylock nut R 520 1015 2 3 8 x 16 x 3 socket screw bolt T 520 1065 2 M5 x 8 x 20 mm socket pin screw U 520 9260 1 M10 penta pin tool V 520 9525 3 M8 x 1 25 x 12 mm socket head screw W 530 9306 1 5 16 18 nylock nut X 500 1082 1 5 16 1...

Страница 2: ...shers E and flat washers F Note Leave screws slightly loose until all are attached then tighten all screws securely Attach base plate B to concrete floor Use six Rawl Bolt concrete expansion anchors H Drill 3 8 dia holes to a minimum depth of 2 G T Flat panel weight is restricted to a maximum of 150 lb 68 kg Interfacing flat panel into electrical system at installation site must conform to local e...

Страница 3: ...ket J to tube support K with four screws P using penta pin tool U Insert four screws and washers P F into tilt bracket J Do not fully tighten Leave 1 4 of exposed thread between tilt bracket J and washers F Q K N J P K Attach tube support K to neck tube N using two screw bolts R nuts Q and washers F as shown Insert rubber grommet G into neck tube N P F 1 4 EXPOSED THREAD G F F R ...

Страница 4: ... L to adapter bracket purchased separately and may appear different than illustrated with eight screws P shown right Attach swivel bracket M to adapter mount L using shoulder bolt X washers Y and nut W as shown below FOR HORIZONTAL MOUNT secure with three screws V shown below left FOR VERTICAL MOUNT secure with three screws V shown below right M L X Y Y W V SLOT V L P ADAPTER BRACKET ...

Страница 5: ...service call 1 800 729 0307 or 708 865 8870 5 of 6 Hook swivel bracket M onto tilt bracket J Adjust tilt 0 to 15 and tighten screws P using penta pin tool U Adjust swivel and tighten two screws T securing neck tube N J N T ADAPTER BRACKET AND FLAT PANEL MAY APPEAR SLIGHTLY DIFFERENT THAN ILLUSTRATED 360 SWIVEL P M ...

Страница 6: ... 90 without detaching swivel bracket M follow detail one through detail three REMOVETWO SCREWS V ROTATEMONITOR 90 AND TIGHTEN SCREW V INSERT AND TIGHTENTWO SCREWS V DETAIL 3 DETAIL 1 DETAIL 2 LOOSEN SCREW V 2004PeerlessIndustries Inc Allrightsreserved PeerlessisaregisteredtrademarkofPeerlessIndustries Inc Allotherbrandandproductnamesaretrademarksorregisteredtrademarksoftheirrespectiveowners M ...

Отзывы: