ENG - When installing Peerless wall mounts on a concrete wall, the wall must be at least 8" thick with a minimum
compressive strength of 2000 psi. When installing Peerless wall mounts on a cinder block wall, the cinder blocks
must meet ASTM C-90 specifications and have a minimum nominal width of 8". Do not drill into mortar joints!
Be sure to mount in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. It is
suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid
breaking out the back of the hole when entering a void or cavity. Never attach concrete expansion anchors to
concrete or cinder block covered with plaster, drywall or other finishing material.
WARNING
Mark mounting holes.
ENG
cover line
ENG
2.5"
(64mm)
5/16"
(8mm)
Do not drill into mortar joints.
ENG
Drill mounting holes into supporting surface
(2.5" (64mm) minimum depth required).
ENG
1/16"
B
F
cover line
ENG