5 of 6

 ISSUED: 12-16-16   SHEET NO: 128-9180-1

Cut tie wire (

G

)

 

into four pieces of equal length. Insert wires through ends of turnbuckles. Twist each wire around 

itself at least four times.  Drill holes for four ceiling anchors (see “Various Anchoring Methods"). Position the holes 
so that when the tie wires (

G

) when attached and taut will angle out at 15

O

. Drill a fi fth anchor hole directly above 

the 

center

 of the ceiling tray.  Pull tie wires tight and attach to ends of ceiling anchors (or truss).  Again twist each 

wire around itself at least four times.  When this step is complete, the weight of the ceiling tray should be supported 
by the tie wires.  

Note: 

20’ (6.1 m) of tie wire (

G

) is provided. If space between the true ceiling and suspended 

ceiling is more than 36" (914 mm), additional wire (12 gauge annealed, steel, black) will be needed.

VARIOUS ANCHORING METHODS Max. UL Load Capacity : 250 lbs. (113 kg) 

Solid Concrete

Drill 1/4" (6 mm) dia. holes 1.5" (38 mm) 
deep.  Hammer in Concrete Anchor (

K

) using 

Rawl #3250 setting tool or equivalent.

J

K

Truss Ceiling

No anchor required. After attaching tie 
wire to turnbuckle loop upper end around 
ceiling truss. Pull tie wire tight and twist it 
around itself at least four times.

4

Run the safety cable (

H

) through the remaining 

ceiling anchors. Pass each end through holes in 
ceiling plate reinforcements and join with cable 
clamp (

I

). 

DO NOT TIGHTEN YET!

Suspended Ceiling Kit installation is now complete. 
After all components (Mount, Extension Column, 
etc.) and equipment (monitor, VCR, etc.) have 
been attached, tension the tie wires by adjusting 
turnbuckles (

F

). 

Load must be carried by tie wires 

- not suspended ceiling runners

. Finally, take up 

the slack in safety cable

 

(

H

) leaving it slightly loose. 

Tighten both safety cable clamps (

I

). 

5

A

G

G

G

G

DETAIL 1

Ceiling Runner

DETAIL 2

Safety Cable and 

Cable Clamp

H

I

H

Knockout panels are 
provided for electrical outlet 
boxes and antenna leads.

F

•  When installing Peerless ceiling mounts on 

wood joist/beam covered with gypsum board 
(drywall), verify that the joists or beams are a 
minimum of 2" x 4" nominal size. Do not install 
over gypsum board thicker than 5/8".

WARNING

•  Installer must verify that the ceiling will safely 

support four times the combined weight of all 
attached equipment and hardware.

WARNING

•  When installing Peerless ceiling mounts on a 

concrete ceiling, the ceiling must be at least 8" 
thick with a minimum compressive strength of 
2000 psi. Never attach expansion anchors to 
concrete covered with plaster, drywall or other 
fi nishing material.

WARNING

Wood Joists or Beams

Use stud fi nder to locate and mark 
stud center lines. Drill 5/32" (4 mm) 
dia. holes 2" (51 mm) deep.  Fully 
insert eye bolts (

J

). Mounting hole 

must center on stud.

© 2016, Peerless Industries, Inc. All rights reserved.

 