Страница 1: ...TION INTERFACE GUIDE Aug 30 2022 FREIGHT DOORS I CAR GATES I CAR ENCLOSURES TECHNICAL SUPPORT 1 800 787 5020 ext 275 THE PEELLE COMPANY USING AS REPLACEMENT CONTROLLER Confirm software version on exis...

Страница 2: ......

Страница 3: ...HT CURTAIN OPTIONAL 10 3 0 CAR DOOR GATE CONTROLLER INSTALLATION 11 3 1 CAR DOOR LOCATION AND WIRING LAYOUT 11 3 2 CAR DOOR POWER CONNECTIONS 12 3 3 CAR DOOR ENCODER 13 3 4 CAR DOOR GATE OPERATOR 14 3...

Страница 4: ...IRELESS CONTROLLER INSTALLATION INTERFACE GUIDE Aug 30 2022 7 0 TROUBLESHOOTING 29 7 1 INDEPENDENT MODE 29 7 2 AUTOMATIC MODE 30 7 3 ELEVATOR INTERFACE OPERATION 31 7 4 ERROR CODES 32 7 5 LANDING DOOR...

Страница 5: ...he door controllers See job specific wiring diagrams for disconnect and fuse requirements 1 0 SAFETY WARNING Enclosure Conduit Connections TYPE 1 4 4X Indoor Use Only CAUTION Non metallic enclosure do...

Страница 6: ...de No Date 265 EN WIRELESS CONTROLLER INSTALLATION INTERFACE GUIDE Aug 30 2022 Mount the Landing door Controller to the hoistway wall Use 1 4 inch hardware 2 0 LANDING DOOR CONTROLLER INSTALLATION 2 1...

Страница 7: ...TROLLER INSTALLATION INTERFACE GUIDE Aug 30 2022 2 2 LANDING DOOR WIRING LAYOUT STANDARD OPERATORS Operator Encoder Interlock Operator Landing Door Junction Box or Trough EUD Hall Pushbuttons H O I S...

Страница 8: ...e room disconnect 10 amp circuit for each line of doors Use 14AWG 2mm copper wire for power connection ON OFF switch disconnects both lines If neutral is not used main disconnect must break both lines...

Страница 9: ...e No Date 265 EN WIRELESS CONTROLLER INSTALLATION INTERFACE GUIDE Aug 30 2022 GND COMM B A 12V 2 4 LANDING DOOR ENCODER Install and wire encoder same side as the controller Do not extend the encoder w...

Страница 10: ...E Aug 30 2022 2 5 LANDING DOOR OPERATORS STANDARD OPERATORS Wire both door motors in parallel Use 18AWG 1mm wire in conduit for motor connection Do not combine motor wires with control wires in same c...

Страница 11: ...STOP AUX1 INPUT COM V V AUX2 1 2 3 4 5 6 7 Emergency Unlocking Device Add jumper where EUD s are not provided For automatic door operation ALL the EUD switches have to be in the RUN position as shown...

Страница 12: ...X2 1 2 3 4 5 6 7 Door Lock Contact DI connect to elevator controller The ZONE indicator will go ON solid when the ZNS contact is made for the door connected to that controller when elevator is at the...

Страница 13: ...BUTTON HDC 2 Where provided wire landing station door CLOSE pushbutton as shown When elevator car is within floor ZONE pushbutton inputs will be transmitted to the Car Door controller for connection t...

Страница 14: ...ALLATION INTERFACE GUIDE Aug 30 2022 2 9 LANDING DOOR LIGHT CURTAIN OPTIONAL Install and wire Landing Door Light Curtain where provided Note V to RE contact must close when beams are blocked RE 8 V Se...

Страница 15: ...LLATION INTERFACE GUIDE Aug 30 2022 3 0 CAR DOOR GATE CONTROLLER INSTALLATION 3 1 CAR DOOR LOCATION AND WIRING LAYOUT Mount the Car Door Controller to the car door rail spreader Mount to same side as...

Страница 16: ...e room disconnect 10 amp circuit for each line of doors Use 14AWG 2mm copper wire for power connection ON OFF switch disconnects both lines If neutral is not used main disconnect must break both lines...

Страница 17: ...ext 275 THE PEELLE COMPANY Guide No Date 265 EN WIRELESS CONTROLLER INSTALLATION INTERFACE GUIDE Aug 30 2022 3 3 CAR DOOR ENCODER Install and wire encoder Do not extend the encoder wire GND COMM B A 1...

Страница 18: ...ERFACE GUIDE Aug 30 2022 Car Door Controller 3 4 CAR DOOR GATE OPERATOR Use 18AWG 1mm wire in conduit for motor connection Do not combine motor wires with control wires in same conduit Note Low speed...

Страница 19: ...AM MOTOR Use 18AWG lmm wire in conduit for motor connection Do not combine motor wires with control wires in same conduit 4 5 6 Where provided on wide landing doors wire opposite side retiring cam mot...

Страница 20: ...1 800 787 5020 ext 275 THE PEELLE COMPANY Guide No Date 265 EN WIRELESS CONTROLLER INSTALLATION INTERFACE GUIDE Aug 30 2022 3 6 CAR DOOR REVERSING EDGE OPTIONAL Wire reversing edge as shown where pro...

Страница 21: ...N WIRELESS CONTROLLER INSTALLATION INTERFACE GUIDE Aug 30 2022 3 7 WARNING BUZZER Install and wire door close warning buzzer as shown See parameter 94 for constant or pulsing tone BUZZER RED BLACK BUZ...

Страница 22: ...ACE GUIDE Aug 30 2022 4 0 COMMISSIONING Make sure all Landing Doors and Car Doors are adjusted and run freely by hand in the door guides without binding or sticking 4 1 INSTALL BATTERIES Install NIMH...

Страница 23: ...cess the setting for that parameter Change the setting by pressing the buttons Once the desired setting is displayed press the ENTER button to save the setting Parameters can only be modified in IND m...

Страница 24: ...parameter Change the setting by pressing the buttons Once the desired setting is displayed press the ENTER button to save the setting Parameters can only be modified in IND mode 5 Change parameter 02...

Страница 25: ...the following Sequence of Operation using the OPEN CLOSE and RETCAM buttons 1 Remove elevator control inputs to DO DC SE DCM 2 Make sure the controllers are set to AUTO 3 Use the OPEN CLOSE and RETCAM...

Страница 26: ...LONG TERM POWER LOSS In the event of an extended power loss battery backup power will be lost After power up with the elevator car at a landing and upon automatic initiation of either open or close t...

Страница 27: ...r according to elevator control prints Do not use V or V DO Door Open 1 Constant signal required to open doors DC Door Close 2 Constant signal required to close doors SE Nudging 3 Constant signal requ...

Страница 28: ...ing door and car door are open DOOR CLOSED output relay Normally open contact closes and normally closed contact opens when landing door and car door are closed USER 1 output relay Default Normally op...

Страница 29: ...are closed 2 All DI hoistway door lock contacts should be connected in series and the contacts be made when all doors are locked When the elevator controller is signaled all doors closed through the D...

Страница 30: ...11 Learn Speed set learn and power up speed 40 70 40 40 12 Torque Boost 10 40 40 10 23 Open High Speed set the opening high speed 35 99 99 99 24 Open Deceleration Zone set distance of deceleration ra...

Страница 31: ...Setting 00 01 N A 00 00 landing door USER limit car door USER limit sets USER relay output on car door controller 01 car door USER limit sets USER relay output on car door controller 65 USER 1 options...

Страница 32: ...or Close Option 00 Constant DO and DC operation 01 Momentary DO and DC operation 00 01 N A 00 93 Power Up landing door speed unzoned only 00 learn speed until final open close limit 01 normal profile...

Страница 33: ...ng Operational profile not learned Set parameter P10 to Lr to initiate learn sequence Encoder set screw loose Ensure set screw is tight on encoder shaft See Landing Door encoder wiring See Car Door en...

Страница 34: ...n at Landing Door controller and corresponding Car Door controller Check all interlock zone micro switches Only one zone micro switch can be on at a time on one channel Duty timer for motor has been e...

Страница 35: ...open or final close increase the following parameter s in multiples of 5 until fixed Open direction P27 Close direction P48 Elevator controller is sending outputs to Peelle controller but no Landing C...

Страница 36: ...rror codes first two digits 01 Landing door motor run error 02 Car door motor run error 04 Car motor over duty 08 retiring cam motor over duty Landing door error codes first two digits 01 Landing door...

Страница 37: ...g applied to motors Landing Zone Zone is ON solid when elevator is at a floor with retiring cam extended and door unlocked Input indicator 3 ZNS is ON when door is ZONED Zone and 3 are OFF when doors...

Страница 38: ...ning Door Stop Sign is OFF when power is being applied to motor Landing Zone Zone is ON solid when elevator is at a floor with retiring cam extended and door unlocked Zone is OFF when all doors are lo...

Страница 39: ...nt Class Digital Transmission System Wireless Network 802 15 4 LR WPAN standard Wireless Frequency 2 4GHz Wireless Output 0 094 Watts Wireless Range 100m floor to floor up to 99 floors User Interface...

Страница 40: ...ser s authority to operate the equipment under FCC This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment The user should avoid prolonged exposure within...

Страница 41: ...product is used as intended and the following standards applied Product Wireless Freight Door Controller 2 4GHz 802 15 4 Transceiver Module Manufactured by The Peelle Company Ltd Trade mark Peelle Mo...

Страница 42: ...38 FREIGHT DOORS I CAR GATES I CAR ENCLOSURES TECHNICAL SUPPORT 1 800 787 5020 ext 275 THE PEELLE COMPANY Guide No Date 265 EN WIRELESS CONTROLLER INSTALLATION INTERFACE GUIDE Aug 30 2022...