35
FREIGHT DOORS
I
CAR GATES
I
CAR ENCLOSURES
T
ECHNICAL
S
UPPORT
1-800-787-5020 ext 275
THE PEELLE COMPANY
®
Guide No.
VERSION:
Date:
254-EN
WIRELESS CONTROLLER & BRIDGE
INSTALLATION & INTERFACE GUIDE
Mar 07 / 2018
6.0 CONTROLLER SETTINGS
6.1 DOOR MOTION PROFILES
6.2 CAR & LANDING DOOR CONTROLLER PARAMETERS
Parameter Description
Range
Landing Pre Set
Car Pre Set
1
Reset Overload (00 = Do not reset, 01 = Reset)
00-01
00
00
2
Controller Type: Car Door, Landing Door, Slave
Cd,Ld,SL
Ld
Ld
3
Channel: set a unique Channel for each line of doors
11-22
15
15
Floor: set a unique Floor address for each Landing Door
(note: 00 is not a valid address)
10
Learn Command: used to learn the opening
Lr or --
--
--
11
Learn Speed: set learn and power-up speed
40-70
40
40
Car Door Duty: increase the car door duty
Sd = Standard Duty, Hd = Heavy Duty
23
Open High Speed: set the opening high speed
20-99
99
99
24
Open Deceleration Zone: set distance of deceleration ramp
00-30
10
10
25
Open Low Speed: set low speed open
20-99
50
30
26
Open Low Speed Zone
00-30
10
10
27
Open Hold Torque: set the hold open torque
00-50
25
20
41
Close High Speed: set the closing high speed
20-99
99
85
42
Close High Speed Torque Limit
30-99
99
99
43
Close Nudging Speed
30-70
N/A
50
44
Close Nudging Speed Torque Limit
30-99
N/A
99
45
Close Deceleration Zone: set distance of deceleration ramp
00-30
10
10
46
Close Low Speed: set low speed close
20-99
50
30
N/A
12
Sd-Hd
N/A
Sd
4
00-30
00
Содержание 254-EN