Guide No.

VERSION:

Date: 

254-EN

WIRELESS CONTROLLER & BRIDGE 

INSTALLATION & INTERFACE GUIDE

Mar 07 / 2018

FREIGHT DOORS

I

CAR GATES

I

CAR ENCLOSURES

T

ECHNICAL 

S

UPPORT

 1-800-787-5020 ext 275

THE PEELLE COMPANY

®

254

-EN

WIRELESS CONTROLLER

& BRIDGE

INSTALLATION &

INTERFACE GUIDE

Содержание 254-EN

Страница 1: ...THE PEELLE COMPANY Guide No VERSION Date 254 EN WIRELESS CONTROLLER BRIDGE INSTALLATION INTERFACE GUIDE Mar 07 2018 FREIGHT DOORS I CAR GATES I CAR ENCLOSURES TECHNICAL SUPPORT 1 800 787 5020 ext 275...

Страница 2: ......

Страница 3: ...ANDING DOOR EMERGENCY UNLOCKING DEVICE EUD 9 2 9 LANDING DOOR ZONE SWITCH ZNS 10 2 10 LANDING DOOR HALL PUSHBUTTONS 11 2 11 LANDING DOOR LIGHT CURTAIN OPTIONAL 12 3 0 CAR DOOR GATE CONTROLLER INSTALLA...

Страница 4: ...R 32 5 4 SEQUENCE OF OPERATION 32 5 5 POWER UP MODE LOSS OF POWER 32 5 6 BRIDGE COMMISSIONING 33 5 7 LANDING AND CAR DOOR INTERLOCKING CIRCUITS 34 6 0 CONTROLLER SETTINGS 35 6 1 DOOR MOTION PROFILES 3...

Страница 5: ...ed for the door controllers See job specific wiring diagrams for disconnect and fuse requirements 1 0 SAFETY WARNING Enclosure Conduit Connections TYPE 1 4 4X Indoor Use Only CAUTION Non metallic encl...

Страница 6: ...E GUIDE Mar 07 2018 Mount the Landing door Controller to the hoistway wall Use 1 4 inch hardware 2 0 LANDING DOOR CONTROLLER INSTALLATION 2 1 LANDING DOOR CONTROLLER MOUNTING Alternate Location Lowest...

Страница 7: ...ONTROLLER BRIDGE INSTALLATION INTERFACE GUIDE Mar 07 2018 2 2 LANDING DOOR WIRING LAYOUT STANDARD OPERATORS OPTION Operator Encoder Interlock Operator Landing Door Junction Box or Trough EUD Hall Push...

Страница 8: ...BRIDGE INSTALLATION INTERFACE GUIDE Mar 07 2018 2 3 LANDING DOOR WIRING LAYOUT EXTRA HIGH TORQUE OPERATORS Operator Encoder Interlock Operator Landing Door Junction Box or Trough EUD Hall Pushbuttons...

Страница 9: ...machine room disconnect 10 amp circuit for each line of doors Use 14AWG 2mm copper wire for power connection ON OFF switch disconnects both lines If neutral is not used main disconnect must break bot...

Страница 10: ...SION Date 254 EN WIRELESS CONTROLLER BRIDGE INSTALLATION INTERFACE GUIDE Mar 07 2018 GND COMM B A 12V 2 5 LANDING DOOR ENCODER Install and wire encoder same side as the controller Do not extend the en...

Страница 11: ...ar 07 2018 2 6 LANDING DOOR OPERATORS STANDARD OPERATORS Wire both door motors in parallel Use 18AWG 1mm wire in conduit for motor connection Do not combine motor wires with control wires in same cond...

Страница 12: ...1mm wire in conduit for motor connection Do not combine motor wires with control wires in same conduit Connect CAN and COMM wires between controllers Notes 1 Low speed winding is not used Cap black wi...

Страница 13: ...ZNS EUD STOP AUX1 INPUT COM V V AUX2 1 2 3 4 5 6 7 Emergency Unlocking Device Add jumper where EUD s are not provided For automatic door operation ALL the EUD switches have to be in the RESET positio...

Страница 14: ...6 7 Door Lock Contact DI connect to elevator controller The ZONE indicator will go ON solid when the ZNS contact is made for the door connected to that controller when elevator is at the landing with...

Страница 15: ...BUTTON HDC 2 Where provided wire landing station door CLOSE pushbutton as shown When elevator car is within floor ZONE pushbutton inputs will be transmitted to the Car Door controller for connection...

Страница 16: ...LLATION INTERFACE GUIDE Mar 07 2018 2 11 LANDING DOOR LIGHT CURTAIN OPTIONAL Install and wire Landing Door Light Curtain where provided Note V to RE contact must close when beams are blocked RE 8 V Se...

Страница 17: ...ON INTERFACE GUIDE Mar 07 2018 3 0 CAR DOOR GATE CONTROLLER INSTALLATION 3 1 CAR DOOR LOCATION AND WIRING LAYOUT Mount the Car Door Controller to the car door rail spreader Mount to same side as the E...

Страница 18: ...machine room disconnect 10 amp circuit for each line of doors Use 14AWG 2mm copper wire for power connection ON OFF switch disconnects both lines If neutral is not used main disconnect must break bot...

Страница 19: ...THE PEELLE COMPANY Guide No VERSION Date 254 EN WIRELESS CONTROLLER BRIDGE INSTALLATION INTERFACE GUIDE Mar 07 2018 3 3 CAR DOOR ENCODER Install and wire encoder Do not extend the encoder wire GND COM...

Страница 20: ...ION INTERFACE GUIDE Mar 07 2018 3 4 CAR DOOR GATE OPERATOR Use 18AWG 1mm wire in conduit for motor connection Do not combine motor wires with control wires in same conduit Note Low speed winding is no...

Страница 21: ...5 RETIRING CAM MOTOR Use 18AWG lmm wire in conduit for motor connection Do not combine motor wires with control wires in same conduit 4 5 6 Y1 Y2 Y3 Where provided on wide landing doors wire opposite...

Страница 22: ...ON Date 254 EN WIRELESS CONTROLLER BRIDGE INSTALLATION INTERFACE GUIDE Mar 07 2018 3 6 CAR DOOR REVERSING EDGE OPTIONAL Wire reversing edge as shown where provided L LNote V to RE contact closes when...

Страница 23: ...DC D0 SE DCM RC BUZZ Car Door Panel Inside the Car 100 240 VAC Light Curtain 1 L1 N Power In LC 1 PLUG Light Curtain Power Supply LIGHT CURTAIN 1 SE 3 Wire light curtain RD1 output as shown use norma...

Страница 24: ...n 3 8 DUAL LIGHT CURTAINS OPTION LIGHT CURTAIN 1 SE 3 Wire light curtain RD1 output as shown use normally open NO signal from light curtain controller LIGHT CURTAIN 2 DCM 4 Wire light curtain RD2 outp...

Страница 25: ...EN WIRELESS CONTROLLER BRIDGE INSTALLATION INTERFACE GUIDE Mar 07 2018 3 9 WARNING BUZZER Install and wire door close warning buzzer as shown See parameter 94 for constant or pulsing tone BUZZER RED B...

Страница 26: ...OR CLOSE BUTTON DC 2 Wire car station door CLOSE pushbutton as shown CAR DOOR STOP BUTTON RC 5 Where provided wire car station door STOP pushbutton as shown The car door STOP button should be normally...

Страница 27: ...OMPANY Guide No VERSION Date 254 EN WIRELESS CONTROLLER BRIDGE INSTALLATION INTERFACE GUIDE Mar 07 2018 4 0 BRIDGE CONTROLLER INSTALLATION 4 1 BRIDGE CONTROLLER LOCATION AND WIRING LAYOUT Elevator Con...

Страница 28: ...machine room disconnect 10 amp circuit for each line of doors Use 14AWG 2mm copper wire for power connection ON OFF switch disconnects both lines If neutral is not used main disconnect must break bot...

Страница 29: ...eries as shown Use 2 shielded twisted pair in travel cable TERMINATING JUMPERS For elevators with front doors only do NOT remove terminating jumper For front rear doors remove terminating jumper on Fr...

Страница 30: ...r door operation A single Bridge Controller is used for front doors or for front and rear door arrangement INPUT COM Add jumper to the INPUT COM from V when car door controller V is used for the input...

Страница 31: ...r Signal should be low whenever car is stopped X11 Fire Service Phase 1 Recall Input required when Fire Service Phase 1 Recall is on X12 Designated Landing Door Input required when elevator is at desi...

Страница 32: ...oor are open Rear Door Closed Relay COM5 Normally open contact closes and normally closed contact opens when landing door and car door are closed USER 1 Relay COM6 Default Normally open contact closes...

Страница 33: ...ess the ENTER button to access the setting for that parameter Change the setting by pressing the buttons Once the desired setting is displayed press the ENTER button to save the setting Parameters can...

Страница 34: ...ION INTERFACE GUIDE Mar 07 2018 8 Set parameter 50 to 01 for CAN_Bridge Operation 9 Set parameter 52 to 00 for Front Car Door or 01 for Rear Car Door 10 Set parameter 65 to 07 for Dual Light Curtain T...

Страница 35: ...ess the ENTER button to save the setting Parameters can only be modified in IND mode 5 Change parameter 02 to Ld setting The LCD display should now read landing door If you have Extra High Torque Door...

Страница 36: ...and car door and retiring cam sequence of operation 4 Reconnect the CAN connector RET CAM CLOSE OPEN ENTER _ 5 4 SEQUENCE OF OPERATION After power up with the elevator car at a landing upon automatic...

Страница 37: ...press the ENTER button to save the setting Parameters can only be modified in IND mode 5 Set parameter 15 to desired Auto Close time Setting 00 Auto Close is disabled Auto Close set times 30 45 60 90...

Страница 38: ...d gates are closed 2 All DI hoistway door lock contacts should be connected in series and the contacts be made when all doors are locked When the elevator controller is signaled all doors closed throu...

Страница 39: ...alid address 10 Learn Command used to learn the opening Lr or 11 Learn Speed set learn and power up speed 40 70 40 40 Car Door Duty increase the car door duty Sd Standard Duty Hd Heavy Duty 23 Open Hi...

Страница 40: ...imit 70 99 75 75 User Limits Setting 00 landing door USER limit car door USER limit sets USER relay output on car door controller 01 car door USER limit sets USER relay output on car door controller 6...

Страница 41: ...A 00 89 Momentary Door Open Door Close Option 00 Constant DO and DC operation 01 Momentary DO and DC operation 00 01 N A 00 93 Power Up landing door speed unzoned only 00 learn speed until final open...

Страница 42: ...BE FRONT 04 DOOR OPEN POSITION FRONT 06 AUX 2 INPUT FRONT 07 LIGHT CURTAIN TEST OUTPUT BRIDGE OPTION ONLY 08 USER 1 POSITION REAR 09 USER 2 POSITION REAR 10 ZONE REAR 11 BUZZ STROBE REAR 12 DOOR OPEN...

Страница 43: ...ARN flashing Operational profile not learned Set parameter P10 to Lr to initiate learn sequence Encoder set screw loose Ensure set screw is tight on encoder shaft See page 5 for Landing Door encoder w...

Страница 44: ...LTIZONE icon on at Landing Door controller and corresponding Car Door controller Check all interlock zone micro switches Only one zone micro switch can be on at a time on one channel Duty timer for mo...

Страница 45: ...open or final close increase the following parameter s in multiples of 5 until fixed Open direction P27 Close direction P48 Bridge controller is sending signals to car door controller but no Landing...

Страница 46: ...door error codes first two digits 01 Landing door motor run error 02 Car door motor run error 04 Car motor over duty 08 retiring cam motor over duty Landing door error codes first two digits 01 Landi...

Страница 47: ...er is being applied to motors Landing Zone Zone is ON solid when elevator is at a floor with retiring cam extended and door unlocked Input indicator 3 ZNS is ON when door is ZONED Zone and 3 are OFF w...

Страница 48: ...not running Door Stop Sign is OFF when power is being applied to motor Landing Zone Zone is ON solid when elevator is at a floor with retiring cam extended and door unlocked Zone is OFF when all door...

Страница 49: ...020 ext 275 THE PEELLE COMPANY Guide No VERSION Date 254 EN WIRELESS CONTROLLER BRIDGE INSTALLATION INTERFACE GUIDE Mar 07 2018 7 7 BRIDGE LCD FRONT or REAR Selector LCD shows indicators according to...

Страница 50: ...up to 99 floors User Interface On board pushbuttons with visual display Visual Display 50mm x 40mm back lit LCD Parameters User adjustable with factory presets and defaults Learn Adjustment Automatic...

Страница 51: ...as the product is used as intended and the following standards applied Product Wireless Freight Door Controller 2 4GHz 802 15 4 Transceiver Module Manufactured by The Peelle Company Ltd Trade mark Pe...

Страница 52: ...FREIGHT DOORS I CAR GATES I CAR ENCLOSURES TECHNICAL SUPPORT 1 800 787 5020 ext 275 THE PEELLE COMPANY Guide No VERSION Date 254 EN WIRELESS CONTROLLER BRIDGE INSTALLATION INTERFACE GUIDE Dec 18 2017...

Отзывы: