34
FREIGHT DOORS
I
CAR GATES
I
CAR ENCLOSURES
T
ECHNICAL
S
UPPORT
1-800-787-5020 ext 275
THE PEELLE COMPANY
®
Guide No.
Date:
224-EN
WIRELESS CONTROLLER
INSTALLATION & INTERFACE GUIDE
May 13 / 2021
FREIGHT DOORS
I
CAR GATES
I
CAR ENCLOSURES
T
ECHNICAL
S
UPPORT
1-800-787-5020 ext 275
THE PEELLE COMPANY
®
224
WIRELESS CONTROLLER
INSTALLATION & INTERFACE GUIDE
Motor Overload / Over Duty
OVERLOAD is ON solid when over current exists
at motor output
Check for shorts on motor line
Check for shorts to ground
Reset of overload is required; set parameter 01
to 01 and press ENTER to clear (must go to IND
mode)
OVERLOAD is flashing when motor run time
exceeds duty
Let motor reset for 5 minutes
Over Duty does not require reset
•
•
•
•
•
•
•
Input Indicators
1
DO - Door open command from elevator
2
DC - Door closed command from elevator
3
SE - Close nudging command from elevator
4
DCM - Fast close command from elevator
5
RC - Retiring cam command from elevator
6
BUZZ - Close warning buzzer command
from elevator
7
AUX2 - Not Used
8
RE - Reversing edge input from car door
Door Stop Sign
Door Stop Sign
is ON whenever
motor is not
running
Door Stop Sign is
OFF when power
is being applied to
motor
•
•
Landing Zone
Zone is ON solid when
elevator is at a floor with
retiring cam extended
and door unlocked
Zone is OFF when all
doors are locked and / or
car is moving between
floors
Doors will not run if
ZONE is not made
Check ZNS and zone
switch
•
•
•
•
Emergency Unlocking Device
EUD is flashing when an EUD
has been
STOP
EUD is OFF when all landing
doors have been
RUN
Floor addresses where EUD is
S
TOP
are shown in the Number
Display
Doors will not run if any EUD is
ST
OP
on the same channel
•
•
•
•
Radio Communication
Antenna is ON solid when elevator is at a floor and
door is ZONED
Antenna is OFF when elevator is travelling
Antenna is Flashing Constant when elevator is not
ZONED
For intermittent flashing in ZONE adjust channel
selection
•
•
•
•
Multiple Zone
MULTIZONE error is shown when
two or more landing door controllers
are ZONED on the same channel
ZONED floor addresses are shown
in Number Display
Check ZONE switches and ZNS
inputs at landings
•
•
•
Number Display
Number display show
encoder count (car door
position)
Approximately 0-50 for
car door closed position
Full count for open
position
Will show floor addresses
in MULTIZONE error
Shows floor addresses
when and EUD is SET
May flash fault codes for
Peelle Use
•
•
•
•
•
•
7.6 CAR DOOR LCD
Содержание 224-EN
Страница 2: ......