Pecron E2000 LFP Скачать руководство пользователя страница 13

Q1: What kind of battery is used in E2000 LFP? How long it can last?

  A: E2000 LFP utilizes high quality UL certified automotive LiFePO4 battery, it can retain 80% of its original capacity at 

         3500 complete charge cycles.

Q2: What devices can E2000 LFP power?

  A: E2000 LFP can power most devices with power consumption less than 2000 watts.

Q3: Can the E2000 LFP be used as UPS?

  A: The UPS function is not supported.

Q4: Can the E2000 LFP be charged while discharging?

  A: Yes, E2000 LFP can run devices while it is being charged. The battery will eventually run out if the discharging is 

         greater than the charging during the pass through charging.

Q5: How to calculate the E2000 LFP running time?

  A: Running Time=Total Capacity(1920Wh) * 0.85 (Depth of Discharge)/Loading Power(Watts)

Q6: Can I use the E2000 LFP indoors and charge the E2000 LFP indoors?

  A: Yes, the E2000 LFP  is safe to use indoors.

Q7: Does E2000 LFP have built-in MPPT controller?

  A: Yes, there are two independent 600W(PV 32V-95V) MPPT charge controllers inside, and one step up 100W(PV 18V) 

         MPPT charge controller, The Voc ( Open Circuit Voltage) of the solar panels should not exceed 95V.

Q8: How to store the E2000 LFP?

  A: Please turn off the unit and then store it in a dry, ventilated place at normal room temperature. Do not place this unit 

         near water sources or a wet/moist environment. For long-term storage, it is recommended to discharge the battery to 
         30% every three months and recharge it to 60% to prolong the battery life.

FAQS

[email protected]

Please read the user manual thoroughly before using this product, and keep this manual in a safe place for future reference. 
Failure to follow the instructions for proper set up, use, and care for the device can increase the risk of serious personal 

injury, death, or property damage. Once you use this device, you are deemed to have understood, recognized and accepted 

all terms and contents of this document. The user shall be responsible for his own actions and all consequences arising from 

failure to use the device in accordance with the “User Manual”, or as authorized in Pecron's current product literature.

In compliance with laws and regulations, Pecron reserves all rights for final explanation, and to change these terms and 
conditions at any time without prior notice. In the event that any revisions are made, the revised terms and conditions shall 
be posted on our website immediately, please visit our website to inform yourself of any changes.

DISCLAIMER

Содержание E2000 LFP

Страница 1: ...Please read the user manual thoroughly before using support pecron com USER MANUAL E2000 LFP...

Страница 2: ...NTRODUCTION DC 12V 18V Charging Port DC 32V 95V Charging Port DC 12V USB Wireless Switch AC 100V 120V Switch DC12V Auxiliary Output AC 100V 120V Output DC12V 5525 Output LCD Display USB A USB C Ports...

Страница 3: ...4 Battery Retain 80 Original Capacity At 3500 Cycles L16 1 W10 H11 6 in 3 5 4H Standard 1 5 2H Fast Charging 1920Wh 25 6V75Ah Over Voltage Overheat Overload Short Circuit Self Recovery L409 W256 H297...

Страница 4: ...mperatures ranging from 20 45 If your working temperature is more than 45 the temperature alarm will flash the unit may stop working Time Indicator DC Out AC Out press and hold to turn on off DC USB W...

Страница 5: ...pecron com EXPANDABLE BATTERY Require Pecron battery expansion cable to expand the capacity by adding extra Pecron 24V battery Do not expand with any battery modules other than the Pecron s this coul...

Страница 6: ...ger Around 3 5 4 Hours Around 1 5 2Hours 2 adapters Car Charging Cable 1 SOLAR CHARGE TIME Pecron E2000 LFP 1 E2000 LFP MC4 Solar Charging Cable pecron 200W 200W 1 400W 2 600W 3 1200W 6 15 16 Hours Th...

Страница 7: ...OC open circuit voltage of solar panel array must be than 95V otherwise it will damage the unit Do not wire more than two 36V AKA 24V solar panels in series or more than four 18V AKA 12V solar panels...

Страница 8: ...Using the pecron 100W 18V 1 100W to charge the E2000 LFP 18V USING SOLAR PANELS TO CHARGE THE E2000 LFP pecron 100W pecron 100W 1 18V is the operating voltage of the solar panels 36V 36V MC4 Solar Cha...

Страница 9: ...0W to charge the E2000 LFP Using the pecron 200W 36V 2 400W to charge the E2000 LFP MC4 Solar Charging Cable 1 36V is the operating voltage of the solar panels pecron 200W 2 36V 36V 72V MC4 Solar Char...

Страница 10: ...to charge the E2000 LFP MC4 Solar Charging Cable 2 36V is the operating voltage of the solar panels pecron 200W 3 36V 36V 72V 36V 36V DO NOT wire three solar panels in series PV GX16MF 5 Port Only wo...

Страница 11: ...charge the E2000 LFP DO NOT wire four solar panels in series 72V 72V MC4 Solar Charging Cable 2 36V is the operating voltage of the solar panels pecron 200W 4 PV GX16MF 5 Port Only work within 32V 95...

Страница 12: ...pecron com Using the pecron 200W 36V 6 1200W to charge the E2000 LFP MC4 Solar Charging Cable 2 Y Branch MC4 Charging Cable 2 Y Branch MC4 Charging Cable 2 pecron 200W 6 36V is the operating voltage o...

Страница 13: ...Q8 How to store the E2000 LFP A Please turn off the unit and then store it in a dry ventilated place at normal room temperature Do not place this unit near water sources or a wet moist environment For...

Страница 14: ...k heavy objects on this product 9 Do not block the air vents during use or leave the device in a non ventilated or dusty space 10 Please avoid impacts fall off and violent vibration Please turn off th...

Страница 15: ...on battery recycling and disposal 2 If the battery cannot be completely discharged due to the failure of the product itself please do not dispose of the battery directly in the battery recycling box a...

Страница 16: ...POWER IT POSSIBLE www pecron com support pecron com...