Peavey PR 15P Скачать руководство пользователя страница 2

2

Intended to alert the user to the presence of uninsulated “dangerous voltage”  within the product’s
enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.

Intended to alert the user of the presence of important operating and maintenance (servicing)
instructions in the literature accompanying the product.

C

CA

AU

UT

TIIO

ON

N::

Risk of electrical shock — DO NOT OPEN!

C

CA

AU

UT

TIIO

ON

N::

To reduce the risk of electric shock, do not remove cover. No user serviceable parts inside.

Refer servicing to qualified service personnel.

W

WA

AR

RN

NIIN

NG

G::

To prevent electrical shock or fire hazard, do not expose this appliance to rain or moisture.

Before using this appliance, read the operating guide for further warnings.

Este símbolo tiene el propósito, de alertar al usuario de la presencia de “(voltaje) peligroso” sin
aislamiento dentro de la caja del producto y que puede tener una magnitud suficiente como para
constituir riesgo de descarga eléctrica.

Este símbolo tiene el propósito de alertar al usario de la presencia de instruccones importantes sobre la
operación y mantenimiento en la información que viene con el producto.

P

PR

RE

EC

CA

AU

UC

CIIO

ON

N::

Riesgo de descarga eléctrica ¡NO ABRIR!

P

PR

RE

EC

CA

AU

UC

CIIO

ON

N::

Para disminuír el riesgo de descarga eléctrica, no abra la cubierta. No hay piezas útiles

dentro. Deje todo mantenimiento en manos del personal técnico cualificado.

A

AD

DV

VE

ER

RT

TE

EN

NC

CIIA

A::

Para evitar descargas eléctricas o peligro de incendio, no deje expuesto a la lluvia o

humedad este aparato Antes de usar este aparato, Iea más advertencias en la guía de operación.

Ce symbole est utilisé dans ce manuel pour indiquer à l’utilisateur la présence d’une tension dangereuse
pouvant être d’amplitude suffisante pour constituer un risque de choc électrique.

Ce symbole est utilisé dans ce manuel pour indiquer à l’utilisateur qu’il ou qu’elle trouvera d’importantes
instructions concernant l’utilisation et l’entretien de l’appareil dans le paragraphe signalé.

A

AT

TT

TE

EN

NT

TIIO

ON

N::

Risques de choc électrique — NE PAS OUVRIR!

A

AT

TT

TE

EN

NT

TIIO

ON

N::

Afin de réduire le risque de choc électrique, ne pas enlever le couvercle. Il ne se trouve à

l’intérieur aucune pièce pouvant être reparée par l’utilisateur. Confiez I’entretien et la réparation de
l’appareil à un réparateur Peavey agréé.

A

AV

VE

ER

RT

TIIS

SS

SE

EM

ME

EN

NT

T

: Afin de prévenir les risques de décharge électrique ou de feu, n’exposez pas cet

appareil à la pluie ou à l’humidité. Avant d’utiliser cet appareil, lisez attentivement les avertissements
supplémentaires de ce manuel.

Dieses Symbol soll den Anwender vor unisolierten gefährlichen Spannungen innerhalb des Gehäuses
warnen, die von Ausreichender Stärke sind, um einen elektrischen Schlag verursachen zu können.

Dieses Symbol soll den Benutzer auf wichtige Instruktionen in der Bedienungsanleitung aufmerksam
machen, die Handhabung und Wartung des Produkts betreffen.

V

VO

OR

RS

SIIC

CH

HT

T::  

Risiko — Elektrischer Schlag! Nicht öffnen!

V

VO

OR

RS

SIIC

CH

HT

T::  

Um das Risiko eines elektrischen Schlages zu vermeiden, nicht die Abdeckung enfernen. Es

befinden sich keine Teile darin, die vom Anwender repariert werden könnten. Reparaturen nur von
qualifiziertem Fachpersonal durchführen lassen.

A

AC

CH

HT

TU

UN

NG

G::

Um einen elektrischen Schlag oder Feuergefahr zu vermeiden, sollte dieses Gerät nicht dem

Regen oder Feuchtigkeit ausgesetzt werden. Vor Inbetriebnahme unbedingt die Bedienungsanleitung lesen. 

Содержание PR 15P

Страница 1: ...PR 15P Powered bi amplified two way speaker system Operations Manual For more information on other great Peavey products go to your local Peavey dealer or online at www peavey com...

Страница 2: ...i n Ce symbole est utilis dans ce manuel pour indiquer l utilisateur la pr sence d une tension dangereuse pouvant tre d amplitude suffisante pour constituer un risque de choc lectrique Ce symbole est...

Страница 3: ...turer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over 14 Unplug this apparatus during lightning storms or when unuse...

Страница 4: ...pu ut t m mi ix xi in ng g b bu ui il lt t i in n M Mo ol ld de ed d i in n h ho or rn n w wi it th h e ex xc ce ep pt ti io on na al ll ly y s sm mo oo ot th h r re es sp po on ns se e a an nd d p pa...

Страница 5: ...ave a ground pin a suitable grounding adapter should be used and the third wire should be grounded properly To prevent the risk of shock or fire hazard always be sure that the mixer and all other asso...

Страница 6: ...sensitivity is set for line level input signals and when the white tab is closer to the front panel the sensitivity is increased by 30 dB so it is suitable for mic level signals 7 7 V VO OL LU UM ME E...

Страница 7: ...r rt ta an nt t S Sa af fe et ty y I In nf fo or rm ma at ti io on n f fo or r M Mo ou un nt ti in ng g t th he e P Pe ea av ve ey y P PR R 1 15 5P P s sp pe ea ak ke er r s sy ys st te em m C Ca au u...

Страница 8: ...ed 1 4 phone plug equipped cable will work well and the balanced input circuitry of the primary input 5 will provide some interference rejection a balanced cable using either the balanced TRS 1 4 phon...

Страница 9: ...hannel 1 can be used for either line level signals or as a mic input and mixed with two other line level signals The PR 15P has plenty of gain so do not overload the speaker system preamp inputs by dr...

Страница 10: ...her device The PR 15P has built in EQ to extend and smooth the natural response of the speakers in the system Bass boost and HF EQ have been applied and the system has a nominally flat response so it...

Страница 11: ...jack will have a gain adjust pad that provides for switching between line level input signals and mic level input signals The system power amplifiers shall have an unfiltered frequency response of 10...

Страница 12: ...emale XLR 1 4 phone jack providing balanced operation with switch selectable mic or line level sensitivity Also has two 1 4 phone jack line level unbalanced inputs with a concentric pair of level cont...

Страница 13: ...13 20 50 100 200 500 1k 2k 5k 10k 20k Frequency Hz 60 70 80 90 100 110 dB SPL re 20 Pa Amplitude Response 1m On Axis Figure 1 F FR RE EQ QU UE EN NC CY Y R RE ES SP PO ON NS SE E C CU UR RV VE ES S...

Страница 14: ...14 N No ot te es s...

Страница 15: ...epairs are covered by warranty Peavey will pay the return shipping charges H Ho ow w T To o G Ge et t W Wa ar rr ra an nt ty y S Se er rv vi ic ce e 1 1 Take the defective item and your sales receipt...

Страница 16: ...ures and specifications subject to change without notice Peavey Electronics Corporation 711 A Street Meridian MS 39301 601 483 5365 FAX 601 486 1278 www peavey com 2003 Printed in the U S A 10 03 8030...

Отзывы: