Peavey Delta Blues 210 Скачать руководство пользователя страница 3

3

IMPORTANT SAFETY INSTRUCTIONS

  

WARNING:

 When using electrical products, basic cautions should always be followed, including the following:

1. 

Read these instructions. 

2. 

Keep these instructions.

3. 

Heed all warnings.

4. 

Follow all instructions.

5. 

Do not use this apparatus near water. 

6. 

Clean only with a dry cloth.

7. 

Do not block any of the ventilation openings. Install in accordance with manufacturer’s instructions. 

8. 

Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus (including amplifiers) that 
produce heat.

9. 

Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than 
the other. A grounding type plug has two blades and a third grounding plug. The wide blade or third prong is provided for your 
safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 

10. 

Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point they exit 
from the apparatus.

11. 

Only use attachments/accessories provided by the manufacturer.

12. 

Use only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is 
used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.

13. 

Unplug this apparatus during lightning storms or when unused for long periods of time.

14. 

Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such 
as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has 
been exposed to rain or moisture, does not operate normally, or has been dropped.

15. 

Never break off the ground pin. Write for our free booklet “Shock Hazard and Grounding.” Connect only to a power supply of the 
type marked on the unit adjacent to the power supply cord.

16. 

If this product is to be mounted in an equipment rack, rear support should be provided.

17. 

Note for UK only: If the colors of the wires in the mains lead of this unit do not correspond with the terminals in your plug‚ 
proceed as follows:

 

a) The wire that is colored green and yellow must be connected to the terminal that is marked by the letter E‚ the earth symbol‚ 
colored green or colored green and yellow.

 

b) The wire that is colored blue must be connected to the terminal that is marked with the letter N or the color black.

 

c) The wire that is colored brown must be connected to the terminal that is marked with the letter L or the color red.

18. 

This electrical apparatus should not be exposed to dripping or splashing and care should be taken not to place objects 
containing liquids, such as vases, upon the apparatus.

19. 

The on/off switch in this unit does not break both sides of the primary mains. Hazardous energy can be present inside the 
chassis when the on/off switch is in the off position. The mains plug or appliance coupler is used as the disconnect device, the 
disconnect device shall remain readily operable.

20. 

Exposure to extremely high noise levels may cause a permanent hearing loss. Individuals vary considerably in susceptibility to 
noise-induced hearing loss, but nearly everyone will lose some hearing if exposed to sufficiently intense noise for a sufficient 
time. The U.S. Government’s Occupational Safety and Health Administration (OSHA) has specified the following permissible 
noise level exposures: 

 

Duration Per Day In Hours 

Sound Level dBA, Slow Response

 

 

90

 

 

92

 

 

95

 

 

97

 

 

100

 

 

1 1⁄2 

102

 

 

105

 

 

1⁄2 

110

 

 

1⁄4 or less 

115

According to OSHA, any exposure in excess of the above permissible limits could result in some hearing loss. Ear plugs or protectors to 
the ear canals or over the ears must be worn when operating this amplification system in order to prevent a permanent hearing loss, if 
exposure is in excess of the limits as set forth above. To ensure against potentially dangerous exposure to high sound pressure levels, it is 
recommended that all persons exposed to equipment capable of producing high sound pressure levels such as this amplification system be 
protected by hearing protectors while this unit is in operation.

SAVE THESE INSTRUCTIONS!

Содержание Delta Blues 210

Страница 1: ...www peavey com Delta Blues 115 210 GUITAR AMPLIFIER Operating Manual ...

Страница 2: ...lisé dans ce manuel pour indiquer à l utilisateur la présence d une tension dangereuse pouvant être d amplitude suffisante pour constituer un risque de choc électrique Ce symbole est utilisé dans ce manuel pour indiquer à l utilisateur qu il ou qu elle trouvera d importantes instructions concernant l utilisation et l entretien de l appareil dans le paragraphe signalé ATTENTION Risques de choc élec...

Страница 3: ... rear support should be provided 17 Note for UK only If the colors of the wires in the mains lead of this unit do not correspond with the terminals in your plug proceed as follows a The wire that is colored green and yellow must be connected to the terminal that is marked by the letter E the earth symbol colored green or colored green and yellow b The wire that is colored blue must be connected to...

Страница 4: ...en Schlag und Erdung zu Schließen Sie nur an die Stromversorgung der Art an die am Gerät neben dem Netzkabel angegeben ist 16 Wenn dieses Produkt in ein Geräte Rack eingebaut werden soll muss eine Versorgung über die Rückseite eingerichtet werden 17 Hinweis Nur für Großbritannien Sollte die Farbe der Drähte in der Netzleitung dieses Geräts nicht mit den Klemmen in Ihrem Stecker übereinstimmen gehe...

Страница 5: ...uit a Le connecteur vert et jaune doit être connectrer au terminal noté E indiquant la prise de terre ou correspondant aux couleurs verte ou verte et jaune du guide b Le connecteur Bleu doit être connectrer au terminal noté N correspondnat à la couleur noire du guide c Le connecteur marron doit être connectrer au terminal noté L correspondant à la couleur rouge du guide 18 Cet équipement électriqu...

Страница 6: ... equipo use algún tipo de apoyo trasero 17 Nota para el Reino Unido solamente Si los colores de los cables en el enchufe principal de esta unidad no corresponden con los terminales en su enchufe proceda de la siguiente manera a El cable de color verde y azul debe ser conectado al terminal que está marcado con la letra E el símbolo de Tierra earth coloreado en verde o en verde y amarillo b El cable...

Страница 7: ...ne voltage supplied You can find the proper voltage for your amp printed next to the IEC line power cord on the rear panel of the unit Each product feature is numbered Refer to the front panel diagram in this manual to locate the particular features next to its number Please read this guide carefully to ensure your personal safety as well as the safety of your amplifier Features 30 watts RMS into ...

Страница 8: ...pment Effects Send 6 Output for supplying signal to external effects or signal processing equipment Treble Middle AND Bass EQ 7 Passive tone controls that regulate high mid and low frequencies respectively Boost Switch 8 Boosts the overall system gain Depress to the in position to activate Reverb 9 Reverberation is an echo effect Rotate clockwise to increase the effect Post Gain 10 Controls the ov...

Страница 9: ...amplifier External Speaker Jack 15 Provided for the connection of external speaker cabinet Minimum total impedance is 16 ohms Remote Switch Jack 16 Provided for the connection of the optional remote footswitch Footswitch is used to select the Lead or Normal channels and defeat tremolo When using remote footswitch always insert the plug fully second click to ensure proper operation Front Panel 13 1...

Страница 10: ...nel Select Out Boost Switch Out Nominal level is with Input Gain 6 Minimum level is with Input Gain 12 Preamp Normal Input Impedance Very high Z 470 K ohms Lead Channel Post Gain 12 Nominal Input Level 40 dBV 10 mV RMS Minimum Input Level 70 dBV 0 3 mV RMS Normal Channel Nominal Input Level 17 dBV 140 mV RMS Minimum Input Level 28 dBV 40 mV RMS Maximum Input Level 0 dBV 1 0 V RMS Equalization Lead...

Страница 11: ... Settings ROCK METAL BLUES COUNTRY ADJUST TO TASTE CHANNEL IN BOOST OUT ADJUST TO TASTE CHANNEL IN BOOST OUT ADJUST TO TASTE CHANNEL OUT IN FOR LEAD BOOST OUT ADJUST TO TASTE BOOST OUT CHANNEL OUT IN FOR LEAD ...

Страница 12: ...ake the defective item and your sales receipt or other proof of date of purchase to your Authorized Peavey Dealer or Authorized Peavey Service Center OR 2 Ship the defective item prepaid to Peavey Electronics Corporation International Service Center 412 Highway 11 80 East Meridian MS 39301 Include a detailed description of the problem together with a copy of your sales receipt or other proof of da...

Страница 13: ...Features and specifications subject to change without notice Peavey Electronics Corporation 5022 Hartley Peavey Drive Meridian MS 39305 601 483 5365 FAX 601 486 1278 www peavey com 2005 80305327 ...

Отзывы: