TROUBLESHOOTING

PROBLEM

CAUSE

SOLUTION

Unit does not run

1. Switch is not on.

2. No power at outlet.

3. Switch is broken.

4. Loose wiring.

1. Turn on switch.

2. Check circuit breaker for power to 

outlet.

3. Replace Switch.

4. Check wiring, tighten as needed.

Unit runs briefly, 

then shuts off on 

overload.

1. Duct length is to long.

2. One or both grills are exhausted.

3. Motor bearing are failing or have 

failed.

4. Internal motor wiring is faulty.

1. Shorten duct length.

2. Clear grills.

3. Replace motor

4. Replace motor

Unit vibrates exces-

sively when oper-

ating.

1. The fan blade is damaged.

2. There is dirt build up on the fan blade.

3. The motor shaft is bent because of a 

severe jolt.

1. Replace fan blade.

2. Clean fan blade.

3. Replace motor.  If necessary, 

replace fan blade.

Unit makes a 

scraping sound 

while running.

1.  A severe jolt has deformed the hous-

ing.

2. A  sever  jolt  has  dislodged  the  mo-

tor  from  the  housing  and/or  the  motor 

mount vanes.

1. Replace the housing or the entire 

unit if necessary.

2.  Replace  the  motor  if  necessary.  

Replace  the  motor  mount  vanes  if 

necessary.

Fan does not run, 

but motor makes 

noise.

1. A severe jolt has deformed the hous-

ing  causing  interference  with  the  fan 

blade.

2.  The  capacitor  has  failed  or  the  ca-

pacitor wire is broken.

1. Repair or replace the housing as 

necessary.

2. Repair or replace the capacitor as 

necessary.

For parts and service contact a Pearson Industries Authorized Service Center, or the 

factory direct at (847) 963-9633 or www.pearsonind.com.

DANGER!

ALL THE SERVICE PROCEDURES BELOW SHOULD BE CONDUCTED WITH THE UNIT 

TURNED OFF AND UNPLUGGED!

Содержание WHIRL

Страница 1: ...r Pearson Industries 5420 Newport Drive STE 56 Rolling Meadows IL 60008 Phone 847 963 9633 Fax 847 963 9733 Toll Free 888 364 9836 5420 Newport Dr Suite 56 Rolling Meadows IL 60008 USA www pearsonind...

Страница 2: ...esigned to work in such environments Serious property damage injury or death may result if used in an ex plosive or flammable environment Keep the unit grounded with a three pronged grounding plug and...

Страница 3: ...e servicing and when not in use 10 Do not handle the fan with wet hands Do not pull or carry the fan by its cord do not use cord as a handle do not close a door on the cord and do not pull cord around...

Страница 4: ...e if your job is considered hazard ous The working environment may contain explosive gases or dust in explosive amounts 4 The outlet to be used must be grounded 5 Make sure that both grills on the fan...

Страница 5: ...2 Clean fan blade 3 Replace motor If necessary replace fan blade Unit makes a scraping sound while running 1 A severe jolt has deformed the hous ing 2 A sever jolt has dislodged the mo tor from the h...

Страница 6: ...8 WHIRL EXPLODED VIEW...

Страница 7: ...ng Screw 1 Well Nut 2 BCV3002 1 Duct Ring Grill 5 BCV3004 1 Fan Blade Assembly 7 BCV3010 1 Motor 110V 50 60 Hz 8 1 1 Rubber Grommet 1 PVC for motor wire 9 BCV3001 1 Vane 10 1 Rivet for Rubber Foot 11...

Страница 8: ...arson dealer This warranty is limited to ninety 90 days for labor from the date of the purchase Thereafter any labor costs incurred will be charged to the customer at the current hourly rate This limi...

Отзывы: