background image

1. For pump installation, the inlet pipe should be as short as 

possible with the least turnings. The pump should be installed 

in ventilated and dry environment. It could be installed outside, 

provided having proper covering to prevent rain and wind.

2. For pipeline use, valves should be installed on inlet and outlet 

pipelines and the inlet pipeline should be installed with check 

valve.

A. Installation precautions for inlet pipelines

1. While installing the electric pump, do not use too soft rubber 

tube for the inlet pipeline, avoiding to be sucked flat.

2. The foot valve should be vertically placed and installed 30cm 

from water bottom to avoid sucking in sands and stones (82);

3. Joints of the inlet pipelines should be sealed with the least 

elbows, no water can be sucked.

4. Diameter of the inlet pipe should be at least in accordance 

with that of the water inlet, so as to avoid too much water loss 

which will influence outlet performance.

5. Pay attention to drop of water level while using, the foot valve 

should not be above the water surface (81).

6. In case the inlet pipe is longer than 10m or its lifting height 

exceeds 4m, the pipe diameter should exceed diameter of water 

inlet of the pump.

7. Ensure the pumped will not be affected by pipeline pressures 

while installing the pipelines.

8. Filter should be installed in inlet pipelines so as to avoid solid 

particles to enter into the electric pump.

B. Installation Precautions of the outlet pipeline

1. Pipe diameter of the outlet pipeline should be at least in 

accordance with that of the water outlet, so as to reduce its 

voltage drop, high flow rate and noise to the minimum.

8. ELECTRICAL CONNECTION

Unless the power is off, do not wiring the junction box.  

The electric pump should have reliable grounding to 

prevent current leakage with leakage protection switch 

being equipped.

1) Electrical connection and protection should be conducted 

according to stipulations. Specification of working voltage is 

marked on the nameplate; please ensure the motor is in ac-

cordance with power supply.

2) In case the working area of the electric pump is too far 

from the power supply, power transmission lines should be 

of a heavier gauge, otherwise the electric pump cannot work 

normally because the voltage drop is too dramatic.

3) In case the electric pump is used outdoor, extended lines 

should apply rubber cables for outdoor use.

1

2

3

4

5

6

7

8

Correct Installation Diagram

1. Drain Plug
2. Electric pump
3. Water tap
4. Outlet pipe
5. Filling plug
6. Tie-in
7. Inlet pipe
8. Foot valve

B1

B2

Incorrect Installation Diagram

~220 V~

220V

switch 

fuse 

pressure 

switch 

junction box 

of the motor 

magnetic 

thermal 

switch 

junction box 

of the motor 

~380 V~

380 V

switch 

fuse 

pressure 

switch 

junction box 

of the motor 

junction box 

of the motor 

magnetic 

thermal 

switch 

Max. water temperature: + 40
Min. Water temperature: +4 

Отзывы: