7. Battery Replacement 

 
If the sign “BAT” appears on the LCD display, it indicates that the 
battery should be replaced.  
Remove  the  back  cover  and  open  the  battery  compartment. 
Replace the exhausted battery with new battery. 
 
Batteries, which are used up dispose duly. Used up batteries are 
hazardous  and  must  be  given  in  the  -  for  this  being  supposed  - 
collective container. 
 
 

NOTE 

 
1.  Keep the instrument dry. 
2.  Keep the probes clean. 
3.  Keep  the  instrument  and  battery  out  of  reach  of  infant  and 
 

child. 

4.  

When  the  symbol  ” 

 

”  appears,  the  battery  is  low  and 

should  be  replaced  immediately.  When  you  install  battery, 
ensure the polarity connections are correct. If you will not use 
the instrument in a long period of time, remove the battery. 

 

 
 
 
 
 
 
 
 
 
 

-20- 

Содержание 5201

Страница 1: ...PeakTech 5201 Bedienungsanleitung Operation Manual Feuchtigkeits Messgerät Moisture Meter ...

Страница 2: ...stolen aus der unmittelbaren Nähe des Gerätes fernhalten Vor Aufnahme des Messbetriebes sollte das Gerät auf die Umgebungstemperatur stabilisiert sein Ersetzen Sie die Batterie sobald das Batteriesymbol leuchtet Mangelnde Batteriespannung kann unpräzise Messergebnisse hervorrufen Sollten Sie das Gerät für einen längeren Zeitraum nicht benutzen entnehmen Sie die Batterie aus dem Batteriefach Säuber...

Страница 3: ... Das Gerät dient zur zerstörungsfreien Verfolgung von Feuchtigkeit in Baustoffen aller Art sowie zur Erkennung der feuchten Verteilung in Wänden Decken und Böden Es eignet sich besonders für die Vorprüfung der Bereitschaft von Baustoffen zur Abdeckung vor der Feuchtemessung von Baumaterialien 2 Technische Merkmale Zeigt schnell den Feuchtigkeitsgehalt der Materialien an LCD Anzeige mit weißer Hint...

Страница 4: ...ndsanzeige Batteriesymbol wird bei ungenügender Batteriespannung im Display angezeigt Abschaltautomatik Nach 10 Minuten Messwerthaltefunktion DATA HOLD Messwert wird in der Anzeige gehalten Spannungsversorgung 3 x 1 5V AAA UM 4 Betriebstemperatur 0 C 50 C 80 RH Lagertemperatur 10 C 50 C 70 RH Abmessungen BxHxT 60 x 245 x 27mm Gewicht 220g 3 ...

Страница 5: ...beschreibung 4 1 Bedienelemente am Gerät 1 Feuchtesensor 2 UP Backlight Symbol Taste 3 ALARM SET Taste 4 DOWN Taste 5 ON OFF Taste 6 LCD Anzeige 7 MEAS Taste Mess Taste 8 Batteriefachabdeckung 4 1 2 6 3 4 5 7 8 ...

Страница 6: ...ltefunktion DATA HOLD 3 Aktueller Feuchtigkeitsmesswert 4 Statusanzeige DRY 5 Statusanzeige RISK 6 Statusanzeige WET 7 Symbol für Maximalwertanzeige MAX 8 Maximaler Feuchtigkeitsmesswert 9 Symbol für Minimalwertanzeige MIN 10 Minimaler Feuchtigkeitsmesswert 5 ...

Страница 7: ...nsors wird dann der Feuchtigkeitswert in der LCD anzeige angegeben Dieser Wert muss unter 0 5 liegen Liegt der Wert nicht bei 0 5 schalten Sie bitte das Messgerät erneut ein und wiederholen Sie den Vorgang Danach beginnt das Messgerät das Objekt zu prüfen Drücken Sie die Taste MEAS erneut die Feuchtemessung wird 30 Sekunden lang auf dem Display automatisch gehalten und das Symbol HOLD wird angezei...

Страница 8: ...ugelkopf muss während der Messung senkrecht zum Messpunkt gehalten und fest gegen die Oberfläche gedrückt werden Metallteile in der zu messenden Oberläche beeinflusse das Messergebnis Messen Sie nur an Stellen welche eine möglichst homogene Materialzusammensetzung haben Bei Materialstärken von weniger als 20 mm besteht die Gefahr dass der Feuchtigkeitswert nicht überschritten wird Vielleicht sind ...

Страница 9: ...ck Wenn der Feuchtemesswert die Grenzwerteinstellungen RISK überschreiten ertönt ein akustisches Signal einmalig alle 2 Sekunden Überschreitet der Feuchtemesswert die WET Einstellungen ertönt das Signal viermal jede Sekunde Hinweis Der RISK Wert ist 0 bis 50 der Standardwert ist 30 Der WET Wert beträgt 50 bis 100 der Standardwert ist 60 Abschaltautomatik Wenn das Gerät nicht mehr verwendet wird sc...

Страница 10: ...ter gegeben werden Nehmen Sie das Gerät nie in Betrieb wenn es nicht völlig geschlossen ist Hinweis 1 Halten Sie das Gerät trocken 2 Halten Sie den Sensor sauber 3 Bewahren Sie das Gerät außerhalb der Reichweite von Kindern auf 4 Wenn das Symbol erscheint sind die Batterien leer und sollten schnellstmöglich ersetzt werden Wenn Sie eine Batterie einsetzen achten Sie auf korrekte Polarität der Batte...

Страница 11: ...ntsorgung im Hausmüll ist laut Batteriegesetz ausdrücklich verboten an einer kommunalen Sammelstelle oder geben Sie sie im Handel vor Ort kostenlos ab Von uns erhaltene Batterien können Sie nach Gebrauch bei uns unter der auf der letzten Seite angegeben Adresse unentgeltlich zurückgeben oder ausreichend frankiert per Post an uns zurücksenden Schadstoffhaltige Batterien sind mit einem Zeichen beste...

Страница 12: ...cher Genehmigung des Herausgebers gestattet Letzter Stand bei Drucklegung Technische Änderungen des Gerätes welche dem Fortschritt dienen vorbehalten Hiermit bestätigen wir dass alle Geräte die in unseren Unterlagen genannten Spezifikationen erfüllen und werkseitig kalibriert geliefert werden Eine Wiederholung der Kalibrierung nach Ablauf von einem Jahr wird empfohlen PeakTech 07 2018 MP EHR MI 11...

Страница 13: ...ns away from the equipment Allow the equipment to stabilize at room temperature before taking up measurement important for exact measurements Replace the battery as soon as the battery indicator BAT appears With a low battery the meter might produce false reading that can lead to electric shock and personal injury Fetch out the battery when the meter will not be used for long period Periodically w...

Страница 14: ...ructively tracing dampness in building material of all kinds as well for detecting damp distribution in walls ceilings and floors It is particulary suitable for pre testing the readiness of building materials for covering prior to concrete moisture measurement 2 Features Quickly displays the moisture content of materials LCD display with white backlight Function for measuring the moisture of build...

Страница 15: ...enetration depth 20 40 mm Low Battery Indication Symbol shown in the display Auto Power Off After 10 Minutes DATA HOLD Holds measurement value in display Power Supply 3 x 1 5V AAA UM 4 Operating Environment 0 C 50 C 80 RH Storage Environment 10 C 50 C 70 RH Size WxHxD 60 x 245 x 27mm Weight 220g 14 ...

Страница 16: ...l Description 1 Moisture Sensor 2 UP Backlight Symbol push button 3 ALARM SET push button 4 DOWN push button 5 ON OFF push button 6 LCD Display 7 MEAS push button 8 Battery compartment rear 15 1 2 6 3 4 5 7 8 ...

Страница 17: ... Indicator 1 Low battery Indication 2 Data HOLD Symbol 3 Current moisture value 4 DRY Status Symbol 5 RISK Status Symbol 6 WET Status Symbol 7 MAX Symbol 8 MAX moisture value 9 MIN Symbol 10 MIN moisture value 16 ...

Страница 18: ... display CAL indication and then moisture value will be displayed in LCD The value must below 0 5 If not please turn the meter on over again and repeat hereinbefore operation Then the meter start to measuring the object Press the MEAS button again the moisture measurement shall latch on the display for 30 sec HOLD symbol will displayed After 30 sec the meter will turns off automatically Note When ...

Страница 19: ...he ball head must be kept perpendicular to the measured material during the measurement pressed firmly against the surface and not slanted Metal parts in the surface will falsify the measurement values Measure only in places that have the most homogeneous possible material composition In the case of material thickness of les than 20mm there is the danger that moisture value maybe the values is not...

Страница 20: ... DOWN button to adjust the threshold Press the SET button shall save the alarm setting and then the meter back to the data hold Mode if the moisture measurement is higher than the RISK alarm setting It shall beep once every 2 sec If moisture measurement exceeded the WET alarm setting it shall beep four time every 1 sec Note The RISK value is adjust 0 to 50 The default value is 30 The WET value is ...

Страница 21: ...y Used up batteries are hazardous and must be given in the for this being supposed collective container NOTE 1 Keep the instrument dry 2 Keep the probes clean 3 Keep the instrument and battery out of reach of infant and child 4 When the symbol appears the battery is low and should be replaced immediately When you install battery ensure the polarity connections are correct If you will not use the i...

Страница 22: ...of old batteries at a council collection point or return them to a local shop at no cost The disposal in domestic refuse is strictly forbidden according to the Battery Regulations You can return used batteries obtained from us at no charge at the address on the last side in this manual or by posting with sufficient stamps Contaminated batteries shall be marked with a symbol consisting of a crossed...

Страница 23: ...e latest technical knowing Technical alterations reserved We herewith confirm that the unit is calibrated by the factory according to the specifications as per the technical specifications We recommend to calibrate the unit again after one year PeakTech 08 2018 MP EHR MI PeakTech Prüf und Messtechnik GmbH Gerstenstieg 4 DE 22926 Ahrensburg Germany 49 0 4102 42343 44 49 0 4102 434 16 info peaktech ...

Отзывы: