29
4.4. AC Current
Range
Resolution
Accuracy
1000 A
1 A
2,0% rdg. + 5 dgt.
Overload protection: 1000 A
Position error:
± 1% of reading
Frequency range:
50/60 Hz
4.5. Resistance
Range
Resolution
Accuracy
400
100 m
1,0% rdg. + 4 dgt.
4 k
1
1,5% rdg. + 2 dgt.
10
400 k
100
4 M
1 k
2,5% rdg. + 3 dgt.
40 M
10 k
3,5% rdg. + 5 dgt.
Overload protection: 250 V AC/DC
4.6. Frequency
Range
Resolution Accuracy
Sensitivity
5 Hz
1 mHz
1,5% rdg.+5 dgt
10 V
rms
min.
50 Hz
10 mHz
1,2% rdg.+2 dgt
500 Hz
100 mHz
5 kHz
1 Hz
50 kHz
10 Hz
100 kHz
100 Hz
Overload protection: 250 V AC/DC
4.7. Duty cycle
Range
Resolution
Accuracy
0,5...99,0 %
0,1%
1,2% rdg.+2 dgt.
Pulse width: 100 µS
– 100 ms
Frequency: 5 Hz
– 100 kHz
Overload protection: 250 V AC/DC
4.8. Continuity
Audible Threshold
Test current
< 100
< 1 mA
Overload protection: 250 V AC/DC