16
3.2 Circuit Diagram
(See Fig. 30)
.
Electric Component
E. Level two platforms and install anchor bolts.
1. Check by level bar and use the shims to adjust the platforms until two platforms are
in the same level
(
See Fig.31
).
Item
Name
Code
Specification
Item
Name
Code
Specification
1
Power switch
QS
380V AC
10
Push button
UP
Duplex
2
Fuse
FU1
25A
11
Push button
LOCK
Duplex
3
Fuse
FU2
3A
12
Push button
Down1
Triple
4
AC contactor
KM
24V AC
13
Push button
Down2
Duplex
5
Thermal relay
FR
12A-18A
14
Motor
M
Single Phase
6
Time relay
KT
24V AC
15
Buzzer
H
24VAC
7
Limit Switch
SQ
(
1~2
)
10A
16
Transformer
TC
24V AC
8
Hydraulic
solenoid valve
Y1
24V AC
17
Intermediate
relay
KA
24VAC
9
Air solenoid
valve
Y2
AC 24V
Fig. 30
PII
PI
Using the Level Bar for
the measurement
Fig. 31