![Peak NM60L Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/peak/nm60l/nm60l_user-manual_1517244010.webp)
NM60L- Nitrogen Gas Generator
UM – NM60L
Maintenance
Inlet Filter / Separator Elements
These should be changed at intervals as indicated below. In addition filter bowls
should be cleaned and, the operation of the auto-drains should be checked.
The Air supply to Generator MUST be turned OFF and the Generator MUST be
de-pressurised prior to attempting to remove ANY filter bowl. Failure to do
this may cause injury.
Inlet Breathing Air Filter / Separator Elements
The top Filter Element (00-4427) should be changed at 12-month intervals. The
bottom element should be changed at 12-month intervals. The Part Numbers are as
shown in the drawings below.
RAC Element
Prt. # 00-4427
Coalescing Element
Prt. # 00-4424
Auto Drain Prt #02-4485