PCAN-Router Pro FD – User Manual
42
Parameter
Value Range
CAN ID
Extended 29-bit CAN ID specified in hexadecimal format with
a value larger than 7FF.
First Data Byte
1 = Tracing is started.
2 = Tracing is stopped.
Note:
The specified CAN ID must not be used on any connected
CAN bus. By default, this feature is commented out to prevent
unintended behavior.
7.3
Configuration of the Ethernet
Connection
Since version 1.1.0.11 the data logger firmware supports the PCAN-
Router Pro FD with Ethernet interface (IPEH-002222). For the
configuration of the interface and its usage the
config.txt
has
been extended. The additional settings are described in the
following subchapters.
Note:
When using a regular PCAN-Router Pro FD without
Ethernet, the additional settings are ignored.
7.3.1
IP Address
This setting controls the activation of the Ethernet interface and the
assignment of the IP address. When assigning addresses in an IP
network, the IP address can be assigned automatically by a DHCP
server or manually.
ETH_IP=DHCP
Option
Description
No value. Disables the Ethernet interface.