19
High limit swit
ch
wire
○
C
Connecting 11
#
& 12
#
(NC)
of limit switch to terminals
3
#
& 5
#
of control box
When the cross beam is lowered to 300mm,
the slider will access to the drive lever of
lower limit switch, and stop the lift.
51
34
45
3
N. Install electrical system
1. Install high limit switch
(See Fig. 30)
2. Install lower alarm limit switch
(See Fig. 31)
Fig. 30
Fig. 31
1
40
43
42
65
39
Connecting 13
#
& 14
#
(NO)
of limit switch to terminals
8
#
& 10
#
of control box
Lower limit swit
ch
wire
○
D
300mm
Содержание 409A
Страница 1: ...0 FOUR POST LIFT Model 409A A440A ...
Страница 9: ...7 D Install cross beams See Fig 11 Fig 12 3 1 3 Fig 12 Hole towards inside 2 Fig 11 ...
Страница 33: ...31 IV EXPLODED VIEW Model 409A A440A Fig 46 13 74 Optional turnplates ...
Страница 34: ...32 CROSS BEAM CYLINDERS Fig 47 Fig 48 3 ...
Страница 35: ...33 CONTROL BOX SPX ELECTRIC POWER UNIT 220V 50HZ single phase Fig 50 Fig 49 Fig 50 ...
Страница 50: ...8 72114302 12 2015 ...