background image

Genius1024 User Manual Rev 5 PN UM-0018 RSID 1917 15/11/21

Genius 1024

User Manual

Содержание Genius 1024

Страница 1: ...Genius1024 User Manual Rev 5 PN UM 0018 RSID 1917 15 11 21 Genius 1024 User Manual...

Страница 2: ...gs Kit Contents 13 Installation 14 Generator Environment 14 Generator Overview 15 General Dimensions 15 Rear Connections 16 Unit Controls 16 Drain Connection 17 Electrical Connection 18 Start Up Seque...

Страница 3: ...this Manual This manual is intended for end users and has been written as a reference document where you can skip to the relevant information Users can refer to the contents page to find the relevant...

Страница 4: ...ability Re heat technology improves membrane performance and reliability Robust control system improves safety and reliability of units With the Genius 1024 based on proven technology it selectively r...

Страница 5: ...ality of the foregoing that any defect is not the direct or indirect result of lack of repair and or servicing incorrect repair and or servicing use of wrong materials and or incorrect spare parts 2 A...

Страница 6: ...ted conditions are fully understood or met A CAUTION notice denotes a hazard It calls attention to an operating procedure process or similar which if not correctly performed or adhered to could cause...

Страница 7: ...EN 61010 1 2010 Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use Electromagnetic Compatibility Directive 2014 30 EU EN 61326 1 2013 Electrical Equipment for Mea...

Страница 8: ...uipment Safety Regulations 2016 SI 2016 1101 as amended BS61010 1 2010 Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use The Electromagnetic Compatibility Regulat...

Страница 9: ...Guidance Notes PDF produced by the Department for Business Innovation and skills for the UK and here for Europe All PEAK products that are subject to the WEEE directive are compliant with the WEEE mar...

Страница 10: ...e certified to the current in force revision of the following standards in order to cover both Canadian and United States requirements for Safety Requirements for Electrical Equipment for Measurement...

Страница 11: ...89 bar 0 918 cfm 100 psi Exhaust Maximum Flow 25 L min 4 13 bar 0 882 cfm 60 psi Particles 0 01 m Phthalates NONE Suspended Liquids NONE Gas Outlets 3 x BSPP Drain Outlet 1 x BSPP Pressure Gauges 3 NO...

Страница 12: ...e Peak Partner from where the unit was purchased Follow the unpacking instructions posted on the side of the crate It will require two people to remove the unit from the shipping crate and to manoeuvr...

Страница 13: ...ittings Kit are as follows 1 Teflon Tubing x 9m 2 6mm PE Tubing x 3m 3 Compression Fitting x 3 4 6mm Push Fit Fitting x 1 5 Flow Control Silencer x 3 6 UK Mains Power Cable 230v x 1 7 EU Mains Power C...

Страница 14: ...ator like all sophisticated equipment is affected by ambient conditions Note should also be taken to the proximity of Air Conditioning outlets These can sometimes give rise to pockets of air with high...

Страница 15: ...15 Generator Overview General Dimensions The generator must always be placed on a flat level surface Failure to do so will affect the performance of the generator WARNING 600 mm 23 6 750 mm 29 5 712 m...

Страница 16: ...Page 16 Rear Connections Unit Controls CURTAIN SOURCE EXHAUST Compression Fitting 6mm Push Fit Fitting Mains Cable Low Pressure LED Power Switch Pressure Gauges Service LED Mute Button...

Страница 17: ...tubing to connect this to a suitable drain connection or container It should be noted that the Generator can expel a considerable amount of water from this dependant on ambient humidity If a containe...

Страница 18: ...Green LIVE L Brown or Black Neutral N Blue or White Electrical requirements are 230VAC nominal 10 However running continuously at voltages outwith this is not recommended Extended periods at extremes...

Страница 19: ...red by watching the output pressure gauge on the front panel This will climb to the factory set pressure as noted in the specifications Once this pressure is reached the compressors will continue to r...

Страница 20: ...leak in the gas supply between the generator and the application can lead to a reduction in efficiency Tubing Lengths The diameter of the tubing which will be connected to the gas outlets is importan...

Страница 21: ...rator is designed to operate in either a cyclic mode or run continuously this will be dependent on the output flow The cyclic rate of the compressors will depend on the gas demand of the application t...

Страница 22: ...ase Interval Component Visit 12 Months Genius 1024 Annual Maintenance Kit www peakscientific com ordering Please quote your generator serial number when ordering your Annual Maintenance Kit to ensure...

Страница 23: ...the LED on Stage 2 If the service is not completed the generator will continue to run After 2 weeks the service LED indicator yellow will start to flash This is to make the user aware that the service...

Страница 24: ...to install and setup your generator IQ OQ Certified assurance for applications requiring documented qualification Complete plan Swift response by a Peak Service Engineer within 72 hours planned preve...

Страница 25: ...e cloth prior to use Cleaning should only be undertaken with the power switched off and the power cord removed from the rear of the generator Under no circumstances should any solvents or abrasive cle...

Страница 26: ...ssure drops to a pre determined set point will the alarm be activated indicating LOW pressure It should be noted that the Generator will continue to operate so long as it can maintain pressure during...

Страница 27: ...c is reporting low pressure Check pressure gauges are showing normal pressure Contact your service provider Yellow SERVICE LED on front panel is on constantly A compressor s due for service Contact yo...

Страница 28: ...ic com For generators that remain unregistered after 1 month from the shipment date the warranty will be considered active from the date of factory dispatch Complete Plan only Go Online or Complete an...

Страница 29: ...Page 29 Header Sub Header Body...

Страница 30: ...Page 30...

Страница 31: ...Page 31...

Страница 32: ...ry leading rapid response service to our customers With Peak Protected your laboratory s productivity becomes our top priority To discuss Peak Protected generator cover and payment options speak to yo...

Отзывы: